Firma: BeF Home, s.r.o. Strana 4 (celkem 9) Platí od: 1. 4. 2014
Vydání: 4
The fireplace insert is made in accordance with EN 13229
1. Protected ceiling made of combustible construction material or as a carring element
2 Substitutive building material: thermal prevention precautions performed
3. Connecting pieces made of steel sheet
4. Thermal insulation layer: back wall, side wall, ceiling, convectional air chamber (see page. 4)
5. Brick veneer
6. Isolation
7. Protected grid
8. Thermal insulation layer
9. Support plate
10. Protected base plate made of combustible material or a support element
11. Anti-dazzle floor protection made of non-combustible material
12. Entry convection air
13. Fireplace insert
14. Grid of outer air
The chimney connection:
If the existing chimney is not provided with a suitable connecting fitting for the fireplace insert, it is necessary to make an additional
connection. The chimney connection height is arrived at the properly situated fireplace insert and an attached smoke flue elbow and a
connecting fitting measured from the top edge of the support plate to the centre of the connecting fitting in the entrance of the connecting
area. Gaps for the surround, insulation, expansion joint, etc. must be taken into account.
Brick veneer and thermal side and back wall insulation:
The brick veneer and thermal insulation can be made after the suitable chimney connection.
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for BeF Home Passive - HOT AIR FIREPLACE INSERTS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of BeF Home Passive - HOT AIR FIREPLACE INSERTS in the language / languages: English as an attachment in your email.

The manual is 0.71 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info