25
Technical data
Marmitek X-10 home automation
Rated Voltage 3-phase, 230 VAC, 50 Hz
Total power consumption < 2 W
Signal transmission > 5 Vpp in 5 Ω at 120 kHz in accordance with
EN 50065-1, EN 50065-2-1, EN 50065-4-1
Transmission synchronization 1 pulse burst at 0°/180°
Signal sensitivity 25 mVpp…6 Vpp at 120 kHz ± 4 kHz
Signal/noise ratio 1.35 : 1
Connection range 2.5 mm
2
solid
Minimum ambient temperature 0 °C
Maximum ambient temperature 40 °C
Atmospheric pressure 86 pkA - 106 pkA
Relative humidity
(non condensing) 30 - 90%
Degree of protection Housing: IP40 according to IEC 60 529
Terminal contact: IP20 according to IEC 60 529
Colour RAL 7035
Standards NEN-EN-IEC 60669-2-1, NEN-EN-IEC 60669-2-2
Housing complies with IEC 60707:
BH 2-30, UL94: V-0
Marking
Subject to technical changes without prior notice.
26
Electrical equipment and systems can be sensitive to signals from
other equipment, which causes electro magnetic disturbance. In
the European Union, countries agreed upon laws for the immunity
(sensitivity) of signals of other equipment as well as equipment
emission (disturbance). When equipment or applications in a certain
surrounding comply with the valid standards, they will not disturb
each other's operations (they are called "Electro Magnetic
Compatible").
For residential surroundings, where the home automation system
Marmitek X-10 is being applied, the European standard for
immunity is standardised in EN 61000-6-1. Equipment that complies
with this standard is resistant to electro magnetic emission of other
equip ment, which complies with the European standard EN 61000-
6-3 for residential surroundings. Experience has shown that in
domestic surroundings, equipment is being used which has an
EMC-emission level that is above the levels stated in EN 61000-6-3.
This equip ment can disturb the correct functioning of the Marmitek
X-10 modules. The immunity of the Marmitek X-10 built-in modules
is therefore revaluated and equivalent to EN 61000-6-2 (the more
severe European standard for immunity in industrial surroundings).
Nevertheless, the application area for Marmitek X-10 will
remain restricted to residential areas.
Undisturbed functioning of Marmitek X-10 automation
27
Marmitek is therefore not responsible for the disfunctioning
of the Marmitek X-10 system as a consequence of equipment
in the building with emission levels that exceed the maximum
allowed levels set as standard for residential, commercial and
semi-industrial surroundings stated in EN 61000-6-3.
Application area Valid European Standard Marmitek X-10
home automation*
Immunity of Emission of Immunity and
equipment equipment
emission standards
Residential 61000-6-1 61000-6-3 Compatible/
Commercial meets the
Semi-industrial requirements
* Condition is that the total Marmitek X-10 system is installed in accordance
with valid instructions supplied by a certified and trained Marmitek X-10
dealer.
L1 L2 L3 N
89,5
72 58
Dimensions
Copyrights
Marmitek is a trademark of Pattitude B.V., FKX40™ is a trademark of
Marmitek B.V. All rights reserved. Copyright and all other proprietary
rights in the content (including but not limited to model numbers, soft-
ware, audio, video, text and photographs) rests with Marmitek B.V. Any
use of the Content, but without limitation, distribution, reproduction,
modification, display or transmission without the prior written consent of
Marmitek is strictly prohibited. All copyright and other proprietary notices
shall be retained on all reproductions.
20320 - 20100929
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Marmitek FKX40 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Marmitek FKX40 in the language / languages: English, Dutch as an attachment in your email.

The manual is 0,12 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info