177
ENGLISH
176
INSTALLATION
Air conditioner and ventilation interface
Use wired remote controller to control when air conditioner indoor unit and ventilation product
are connected and installed at the same time.
- Once power is connection, and the remote controller establishes communication with the in-
door unit, normal operation will commence.
Independent operation Interfaced operation
General
ventilation
Wired
remote
controller
General
ventilation
Wired
remote
controller
General
ventilation
Air conditioner
indoor unit
Direct
ventilation
Wired
remote
controller
General
ventilation
Wired
remote
controller
General
ventilation
Air conditioner
indoor unit
[general ventilation
independent operation]
[General ventilation interfaced operation]
[Direct ventilation interfaced operation]
[Direct ventilation
independent operation]
h Connection method is the same as the air conditioner user manual. (Refer to the remote con-
troller manual group control page.)
h Ventilation units represent general ventilation units and direct expenditure type ventilation
units.
NOTE
!
• During the group control, set only one indoor unit as master.
• During the group control, some functions except default operation setting, fan Setting
Low/medium/high, remote controller lock setting, and time setting may be restricted.
• Slave set indoor unit cannot communicate with remote controller when remote controller
has a connection with only one indoor unit.
Change indoor unit’s master/slave setting.
- Change master/slave setting with switch on the indoor unit PCB for ceiling type cassette and
duct group.
- For details of the wireless remote controller master/slave setting changes, refer to the wire-
less remote controller manual.
- After completing the master/slave setting in the indoor unit, turn OFF the power of the indoor
unit, and turn the power ON again after 1 minute.
Master Slave Slave
GND
GND
12V
Signal cable
Signal cable
Black
Red
Ȗ
(Group control connection)
No. 3 switch OFF: master (factory ship-out based)
No. 3 switch ON: slave
YellowYellow
Yellow
89


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for LG PREMTA000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of LG PREMTA000 in the language / languages: English as an attachment in your email.

The manual is 20,17 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info