INSTALLATION
175
ENGLISH
174
INSTALLATION
Purchase Specialized Company’s Accessories
Group control cable (PZCWRCG3): Connect to indoor unit’s wired remote controller connector
Extension cable (PZCWRC1): Connect to No. cable and slave indoor unit’s wired remote
controller connector
While No. cable is connected, connect No. cable.
Group Control
Connects and controls 2 or more air conditioner indoor units to one wired remote controller.
h Use the group control cable for connection.
Indoor unit Main PCB
Indoor unit 1 Indoor unit 2 Indoor unit 3
Master Slave Slave
RED(12V)
YELLOW(SIG)
BLACK(GND)
YELLOW(SIG)
BLACK(GND)
YELLOW(SIG)
BLACK(GND)
1 2
NOTE
!
• Connect only GND and signal cable to the indoor unit set as slave. (If power cable is also
connected, it may cause loss of communication)
• Inquiries related to the purchase of the cable shall be directed to the specialized company
and the service center.
Check the existence of the event communication in the product manual, and change
master/slave of the remote controller.
- It only supports the interface with event communication applied models (corresponding to the
models after Multi-V Super II).
h For details, refer to ‘Remote controller master/slave‘.
To remove the remote controller from the back plate, insert a flat head screwdriver in the bot-
tom part separation hole and turn clockwise.
- There are 2 separation holes at the bottom side. Slowly separate using each hole.
- During the separation, be careful not to damage the internal parts.
Use the connection cable to connect the indoor unit and the remote controller.
In the following cases, separately purchase and use the cable suitable for the situation.
- Do not install the cable for longer than 50 m. (It may cause communication defect like CH03)
- If the distance between the wired remote controller and the indoor unit is 10 m or longer:
Use 10 m extension cable. (Model : PZCWRC1)
- If several indoor unit products are controlled by one wired remote controller: Use group con-
trol cable. (Model : PZCWRCG3)
Wall
Check if the connector is properly connected
Connection cable
Indoor unit
direction
<Order of Separation>
12 V Red
Signal cable Yellow
GND Black
NOTE
!
• During the wired remote controller installation, do not reclaim in the wall. (It may cause
temperature sensor disorder.)
• Do not install the cable for longer than 50 m. (It may cause communication defect such as
Code CH03)
h During the installation of the extension cable, carefully check the connecting socket and
plug of the remote controller and linked indoor unit.
h If the extension cable is connected in reverse direction, connector will not make a solid
connection causing loss of communications.
h Specification of the extension cable: Use 2547 1007 22# 2core 3shield, 5 Ø or equivalent
or higher level.
88


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for LG PREMTA000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of LG PREMTA000 in the language / languages: English as an attachment in your email.

The manual is 20,17 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info