Thank you for purchasing a Jablotron alarm system. Its reliable operation depends on proper installation. We recom-
mend having this alarm professionally installed. To find a qualified installer, please contact your Jablotron Distributor. The
manufacturer assumes no liability for damages caused by incorrect installation or improper use of this system.
1. Before starting
First select suitable locations for all sensors and accessories. The location of
these sensors should take into consideration the building’s safety and basic rules
for good radio communication. The working range of the wireless accessories from
the control panel is about 100 meters under optimal conditions. However, building
materials can absorb or obstruct radio signals, and communication can also be ef-
fected by interference from other radio signals. For these reasons, you should an-
ticipate a shorter working range for indoor installations. The control panel checks
the radio signals during the installation and if the quality of communication with any
accessory is not sufficient, this item will not be enrolled into the system. No part of
the system, except the outdoor siren, JA-60A, is suitable for outdoor use.
You can connect your PC to the JA-60 control panel, using the PC-60A connect-
ing cable and the Comlink software (see part 14). This option is convenient for
easy programming, diagnostics and storing data about the installation.
2. Control panel installation
The control panel should be easily accessible, but not very visible. There
should be a power socket available and also a telephone line (if the system has
an optional built in dialer).
Note: Only a qualified technician can provide the installation, telephone line connection
and servicing. User is not allowed to open the cover and/or make any modification.
2.1. Opening of the control panel
Fig. 1
Press in the bottom tab via the small slot using a narrow flat screwdriver.
Remove the cover and gently pull the cable to disconnect it from the board.
2.2. Attaching the control panel to the wall
The surface of the wall should be level. Avoid placing the panel in locations
that will result in the antenna being near any large metal objects.
There are two slots for screws on the back side of the rear panel.
Drill a hole and insert one of the provided plastic dowels for the top screw.
Partially tighten the screw, leaving part of its head sticking out.
Place the rear housing over the screw and slide it down so that the screw is
in the middle of the slot.
Now mark the position of the lower screw through the housing hole and
remove the housing. Drill the second hole and insert a second plastic dowel.
Replace the housing on the top screw once again.
Do not tighten the lower screw until after the control panel cables are routed
(AC adapter, tel. line, additional siren etc. – see description bellow).
Fig.2
2.3. Antenna installation
Attach the rubber antenna into the hole on the right hand side by the screw
on the internal board.
The AN-01 optional external antenna can be used to improve the radio com-
munication of the control panel. The AN marked connector for the optional an-
tenna is located on the upper end of the control panel board. If the optional ex-
ternal antenna is connected, the rubber antenna must not be used.
2.4. Connection of the AC adapter
Fig. 3 15VAC
adapter connection
Route the adapter’s output cable (15VAC) to the control panel and connect it
to the panel’s terminals marked AC (see fig. 3.) – arbitrary polarity. Do not
plug the AC adapter into the wall yet.
Use only adapter SELV
Alarm system JA-60 "COMFORT" - 4 - MDY51319
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Jablotron JA-60 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Jablotron JA-60 in the language / languages: English as an attachment in your email.

The manual is 2 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Jablotron JA-60

Jablotron JA-60 Additional guide - English - 1 pages

Jablotron JA-60 User Manual - English - 6 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info