JA-60G Gas leak detector - triggers a Fire alarm when any combustible gas is detected (natural gas, city gas, propane,
butane etc.). The detector is powered directly form the AC power network and it wirelessly transmits information to the
control panel. The JA-60G has a built in siren and an output relay. The relay, for example, can be wired to an electrical
valve to turn off the gas supply when a leak is detected.
power 230V(+10 to -15%) / 50Hz, about 2W
2 sensitivity levels: 10% and 20% of LEL (calibrated for Methane)
LEL = Low Explosivity Level
built in siren 94 dB / 0.3 m
output relay selectable reaction for 1
st
or 2
nd
level
relay contact max.230 V / 5 A
working environment indoor use (-10 °C to +40°C)
detection method catalytic oxidation
communication range max. 50 m (open area)
Controllers
RC-11 Remote control - this key chain tag sized controller can be used to Arm and Disarm
the system. It can also be used to trigger a silent Panic alarm. It is powered by 6V battery and its
working range is up to 30 meters. The RC-11 can also be used separately to control UC receiv-
ing modules directly (pulse, latch or ON and OFF modes).
RC-22 Panic button - is a large size button, which can be easily attached in a selected loca-
tion (under a desk, on the wall etc.). This button can be used to trigger a silent Panic alarm. The
RC-22 can be enrolled to the control panel the same way as the remote control. It has a working
range up to 30 meters. The RC-22 can also be used separately to control UC receiving modules
directly (pulse, latch or ON and OFF modes).
RC-40 Remote control - combines two pairs of buttons (A&B and 1&2). It can be
used to operate multiple wireless Jablotron devices. For example, one RC-40 can
control your car alarm and your house alarm system or two independent partitions in a
house alarm or up to 6 different devices when used with Jablotron UC receivers.
It has a unique optional "keypad locking" feature. It is powered by a 6V battery and its
working range is up to 30 meters.
RC-60 Remote controlcontrols wirelessly the system by using other hardwired devices
(access systems, ID chips, cards reader etc.). It has two control inputs (A and B) and two work-
ing modes. In the first mode input A arms and input B disarms the central unit. In the second
mode input A responds on every impulse by sending arming or disarming signal. Input B re-
sponds on each connection to GND by PANIC signal transmission. It is powered by two batteries
type AAA, lifetime of the batteries 1 year, range up to 100 m, for indoor use.
JA-60D Wireless control keypad -
can operate the system in a similar way as the built in keypad on the control panel (arming,
disarming, no code arming, partial arming, door opening and under duress operation). It has its own Master code and one User code,
which can be programmed arbitrary from the control panel’s codes.
power 3 V
=
, 30
µ
A / 100 mA (2x AAA battery 1,5V)
battery life time about one year
communication range max. 100 m (open area)
working environment indoor use (-10 to +40 °C)
codes 1x Master, 1x User
JA-60E Wire operated keypad - can operate and program the system in exactly the same way as the built-in keypad on the control
panel. It is connected to the control panel by a cable. Up to two keypads can be connected to a single control panel. The alarm sys-
tem's status is indicated by the LED indicators, the built in display and built in buzzer. Illuminated keys can be covered with a closable
cover. The keypad can control the system remotely when using the JA-60U modem.
connection with cable to the JA-60 digital bus connector
connecting cable 4 core cable with RJ connectors (4/4 1:1) or
ordinary telephone cable (terminals)
length of the cable max. 100 m
power supply 10 –14 V (taken from the digital bus)
number of keypads in a system max. 2
working environment indoor use ( -10 to +40°C)
JA-60F Wireless keypad - can operate system in exactly the same way as the built-in keypad on the control panel. It can also be
used for programming and testing of the system. The alarm system's status is indicated by the LED indicators, the built in display and
Alarm system JA-60 “COMFORT” - 32 - MDY51319
32


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Jablotron JA-60 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Jablotron JA-60 in the language / languages: English as an attachment in your email.

The manual is 2 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Jablotron JA-60

Jablotron JA-60 Additional guide - English - 1 pages

Jablotron JA-60 User Manual - English - 6 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info