633391
3
Zoom out
Zoom in
Previous page
1/8
Next page
• CATIII MeasurementCategoryIIIisapplicabletomeasuringcircuitsofinstallationsinbuildings(e.g.electric
socketsorsub-distributions).Thiscategoryalsocoversallsmallercategories(e.g.CATIIformeasuring
electronicdevices).
• CATIV MeasurementCategoryIVisapplicabletomeasuringattheoriginofthelow-voltageinstallation(e.g.main
distribution,electricityprovider’stransferpointstohomes,etc.)andoutdoors.Thiscategoryalsocontainsall
lowercategories.
Pleasepayattentiontothefollowingsymbolsandlabels:
L1- ProbeforphaseL1,negativepotentialatDC
L2+ ProbeforphaseL2,singlepolephasetest,positivepotentialatDC
VACDC VAC=alternatingcurrent
VDC=directcurrent
Display+ PositivepotentialatprobeL2+
Display- NegativepotentialatprobeL2+
Display+- ACvoltage(bothindicatorsfor+and-areon)
12/24/50/120
230/400/690
Displayofratedvoltagerangeinvolt(V)
Rx Displayforcontinuitytest
kΩ Electricalresistanceinkilo-ohm
f Ratedfrequencyrangeofelectr.voltage
I TestcurrentisspeciedinmA(milliampere)
W Electricaltestloadinwatts
Hz Electricalfrequency(Hertz)
Temp°C Permittedoperatingtemperaturerangein°Celsius
ON Maximumdutycycle(DC)inseconds(s)
OFF Minimumoperatingpauseafteratestcycleinseconds(s)
Date Yearofmanufacture
OL Overowindication.Measuringrangeexceeded
---- Powerindicatoronthedisplay
Warningofhazardousvoltage(>50V/AC,>120V/DC(alsofunctionswhenbatteriesareemptyor
evenwithoutbatteries).
Symbolforbuzzeralarm
Apparatusandequipmentforliveworks.Personalprotectivemeasuresareessential.
Rotarydirectioneldindicatorongroundedthree-phasenetworks.L=leftturning,R=rightturning
Protectionclass2(doubleorreinforcedinsulation/protectiveinsulation)
Symbolforthebatterydataused.
2x1.5Vmicrobatteries,LR03,AAA
Replacebatteryindicatorondisplay.Thebatteriesmustbereplacedimmediately,ifthissymbol
appears.
PACKAGECONTENTS
• VC-55withcaptiveprobetipprotection
• 2terminalscrews(Ø4mm,applicableforCATII)
• 2plasticprotectivesheaths,applicableforCATIII/CATIV
• 2microbatteries(AAA/LR03)
• Operatinginstructions
DESCRIPTIONOFCOMPONENTPARTS
1 HandleprobetipL1(-)
2 plasticprotectivesheaths,applicableforCATIII/CATIV
3 4mmterminalscrewstotestoutletsfromthefrontside(built-inoutlet!CATII)
4 ProbetipL1(-)
5 Handgripbarrierwithfasteningbar
6 ProbetipL2(+)
7 LEDmeasurementpointlight
8 LEDlevelindicatorforvoltagerangesandpolarity
9 Coveredsoundopeningforalarmbuzzer
10 Warningofhazardousvoltage(>50V/AC,>120V/DC(alsoindicatedwhen
batteriesareemptyorevenwhennobatteriesarepresent).
Phaseindicatorforsingle-polephasetest
11 Rxindicatorforcontinuitytest
12 Rotarydirectioneldindicator(L=leftturning/R=rightturning)
13Handlegripbarrier
14 LCDscreenfornominalvoltageindicatorandbatteryreplacementindicator
15 ButtonforLEDmeteringpointlight
16 HandleprobetipL2(+)
17 Batterycompartmentwithbayonetlock
18 Connectingcable
19 Probetipprotection
INSERTING/REPLACINGTHEBATTERIES
Thevoltagetesterneedsbatterypowerforitsbasicfunctionasatwo-polevoltagetesterwithavoltagerangeindicatorand
itsadditionalfunctionssuchasmeteringpointlight,continuitytest,phasesequenceindicationor“singlepole”phasetester.
Twomicrobatteries(typeAAA/LR03,includedindelivery)arerequiredforthispurpose.Theuseofrechargeablebatteries
isnotpermitted.
Toinsert/replacethebattery,proceedasfollows:
• Removethevoltagetesterfromallmeteringpointsandattachtheprotectivecovertotheprobes.
• Openthebatterycompartment(17)byreleasingthelockwithaatobject
(e.g.wideslotscrewdriver)ina90°counter-clockwiserotation.Atitsside,asmallgrooveis
exposedthatallowsyouremovethebatterycompartmentcoverfromthedevice.
• Inserttwonewmicro-batteries(LR03/AAA)intothebatterycompartment.Payattentiontothe
polarityindicatedonthebatterycompartmentcover.Ifpossible,usealkalinebatteries.They
guaranteealongerservicelife.
G
OPERATINGINSTRUCTIONS
TWO-POLEVOLTAGETESTERVC-55LCD
ITEMNO.1188073
INTENDEDUSE
Thetwo-polevoltagetesterisaportabletestdevicethatdetectsandindicatesthevoltagelevelsoflowvoltagecircuits.Itis
intendedtoindicateDCandACvoltagesintherangeof12to690V,andpolaritybyapplyingbipolar.Thevoltagerangesare
representedin7levels.
Startingatanominalvoltageof50V/ACor120V/DC,awarningindicatorforthevoltagerangeswillashsignalizingthe
warningofdangerousvoltage.Thiswarningindicationisalsodisplayedwhenthebatteriesareempty.
Thevoltagetestercomplieswiththestandardfortwo-polevoltagetesters(EN61243-3/DINVDE0682-401)andprotection
typeIP64(dustandsplashproof),andisintendedfordryordampindoorandoutdoorlocations.Operatingthedeviceduring
rainfallorprecipitationisnotpermitted.Thevoltagetesterisdesignedforusebyqualiedelectriciansinconjunctionwith
personalprotectiveequipment.
ThedevicefeaturesanLCDdisplaywithanindicatorofthetestvoltagerealvalue,anaudio-visualcontinuitytester,built-in
measurementpointlightandthefunction“singlepole”phasetester.Forthetestertofunctiontwomicrobatteries(typeAAA/
LR03)arerequired.Operationwithrechargeablebatteriesisnotpermitted.
Aphasesequenceindicatorforgroundedthree-phasecurrentisavailable.
ThevoltagetestershallonlybeutilizedinsystemsoftheelectricalmeasurementcategoryCATIII(domesticinstallations/
sub-distributions)upto1000VorinCATIV(attheoriginofthelow-voltageinstallations)upto600Vtogroundpotential.
Thesemeasurementcategoriesalsocompriseallofthesmallermeasurementcategories(e.g.CATIIandCATI).
Thevoltagetestermustbeclaspedbythetwohandles(1and16)whiletakingmeasurements.Donottouchbeyond
thetactilebarriersofthegrippingarea(5and13).Donotcovertheindicatorpanelanddonottouchmetalcontactsand
measurementpoints.
Followalsoanyadditionalsafetyinstructionscontainedinthismanual.
Donotuseunderadverseambientconditions.Unfavourableambientconditionsare:
- Excessivehumidityordampness
- Dustandammablegases,vapoursorsolvents
- Potentiallyexplosiveatmosphere(Ex)
- Thunderstormsorsimilarweatherconditionssuchasstrongelectrostaticelds,etc.
Useotherthanthatdescribedabovecanleadtodamagetotheproductandmayinvolveadditionalriskssuchas,forexam-
ple,shortcircuits,re,electricalshocksetc.Nopartoftheproductmaybemodiedorconverted!Thesafetyinstructionsare
tobeobservedwithoutfail!
SAFETYINSTRUCTIONSANDHAZARDWARNINGS
Thisdevicehasleftourfactorypremisesinasafeandperfectcondition.
Wekindlyrequesttheusertoobservethesafetyinstructionsandwarningscontainedintheenclosedoperatinginstructions
sothisconditionismaintainedandtoensuresafeoperation.Pleasepayattentiontothefollowingsymbols:
Anexclamationmarkinatriangleindicatesimportantinformationcontainedintheseoperatinginstructionsthat
mustbeobservedbyallmeans.
Thelightningsymbolinatrianglewarnsofelectricshockdangerortheimpairmentoftheelectricalsafetyofthe
appliance.
ThisdeviceisCEcompliantandthereforemeetsthenecessarynationalandEuropeanguidelines.
The“arrow”symbolisusedwherespecialtipsandnotesonoperationareprovided.
• Damagesduetofailurefollowingtheseoperatinginstructionswillvoidthewarranty!Wedonotassumeanyliabilityforany
resultingdamage!
• Wedonotassumeanyliabilityforpersonalinjuriesandmaterialdamagescausedbytheimproperuseornon-compliance
withthesafetyinstructions!Anywarrantywillbevoidinsuchcases.
• Theunauthorisedconversionand/ormodicationoftheunitisnotpermittedforsafetyandapprovalreasons(CE).
• Foranyworkcarriedout,theaccidentpreventionregulationsoftheEmployer’sLiabilityInsuranceAssociationforElectri-
calSystemsandOperatingFacilitiesmustbeobserved
• Inschools,trainingfacilities,hobbyandself-helpworkshopstheuseofgaugesandtestersshouldbesupervisedina
responsiblemannerbyqualiedtrainedstaff.
• Extracareshouldbetakenwhenusingthedeviceforthersttime.Therefore,pleasefollowtheoperatinginstructions
carefully.
• Thevoltagevaluesspeciedonthevoltagetesterarenominalvoltages.
• Thedevicemaynotbeexposedtoextremetemperatures,strongvibrationsorhighhumidity.Thereadoutisonlyensured
withinatemperaturerangeof-15to+55°Candarelativeairhumidityofmax.85%(non-condensing).
• Holdthevoltagetesteronlybythedesignatedgrippingareas(1and16).Neverreachbeyondthetactilebarrierofthe
grippingareas(5and13).
• Alwayscheckthatthevoltagetesterisworkingproperlypriorandafteremployment.Measureaknownvoltagesource
(e.g.mainsvoltage230V/AC)rst,andchecktheaccuracyofthereadout.Don’tusethevoltagetesteranylonger,incase
oneormoreindicationrangesfailtofunction.
• Thehousingofthevoltagetestermaynotbedissembledexceptforopeningthebatterycompartmentcover.
• Thevoltagetestermayonlybeusedonsystemswithinthevoltagerangesgiven.
• Thenexthighervoltagerangeonthelevelindicatorstartsat0.85timesthenominalvaluealready.
• TheapplicableDCvoltagelimitvalueforhazardouscontactvoltage(inaccordancewithDINVDE0100,part410)is
indicatedbythelightindicatorat120V.
• TheapplicableDCvoltagelimitvalueforhazardouscontactvoltage(inaccordancewithDINVDE0100,part410)is
indicatedbythelightindicatorat50V.
• Thevoltagetesteronlyworkscorrectlyongroundedlowvoltagesystems.Impropergroundedequipmentorinsulatedbody
protectorscanhaveanadverseeffectonthereadout.
• Iftheneutralwire(N)ortheearthwire(PE)isinterrupted,noreadoutwillbedisplayed!
• Keepthevoltagetesterinacleancondition,andstoreitproperlyinadryplace.
• Thisdeviceisnotatoyandshouldbekeptoutofthereachofchildren.
• Topreventinjuriesplacetheprobetipprotectionbackonthetestprobes,ifthetesterisnotused.
• WhenusingthevoltagetesterintherangeofthemeasurementcategoriesCATIIIandCATIV,itisrecommendedtopush
theincludedplasticprotectivesheath(2)overthetestprobesinordertoreducetheexposedlengthofcontacttips.This
willreducetheriskofapossibleshortcircuitduringmetering.
• CATI MeasurementCategoryIisapplicabletomeasuringcircuitsof
electricalandelectronicequipmentthatisnotdirectlysuppliedwithmainsvoltage(battery-operateddevices,
etc.)
• CATII MeasurementCategoryIIisapplicabletomeasuringcircuitsof
electricalandelectronicequipmentthatisdirectlysuppliedwiththemainsvoltageviaapowerplug.This
categoryalsocoversallsmallercategories(e.g.CATIformeasuringsignalandcontrolvoltages).
VERSION12/14
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Voltcraft VC-55 LCD at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Voltcraft VC-55 LCD in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 1,25 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info