Wait ± 3 minutes until the temperature is displayed on the weather station. Do not press any keys before
the weather station has received data.
Mount both units (see “6. Mounting the Units”) at a distance where the weather station is still able to pick
up the signal from the sensor.
Every time the outdoor sensor is powered up (after e.g. a battery replacement), a random security code will
be transmitted. This code must be synchronized to the base station in order to receive weather data. The
station base must also be powered up when replacing the batteries in the outdoor sensor.
When the weather station is powered up, a short beep will sound and all LCD segments will light for 3
seconds before the station enters into the learning mode. After the learning mode the station will start DCF
radio-controlled time reception and RCC time reception for ± 10 minutes during which it will not be able to
receive any weather data. If the RCC signal cannot be found within 1 minute, the signal search will be
cancelled and will automatically resume every two hours until the signal is successfully captured. Regular RF
link will be established once the RCC reception routine is finished.
Do not press any key during the learning period (± 3 minutes). After both indoor and outdoor data is
displayed you can install the remote outdoor sensor and set the time (if no RCC reception is available). If
there is no temperature reading on the outdoor station make sure both units are within transmission range
or check the batteries. If you press a key before the weather station receives the temperature signal, take
out the batteries and reinstall them after ± 10 seconds.
Time and date are provided by a highly accurate atomic clock. Note that, whenever reception is possible, the
weather station will scan for the DCF radio signal and overwrite a manually set time and date.
6. Mounting the units
a. The Base Station
Place the base station onto a flat surface by deploying the foldable legs at
the back of the unit. The unit can also be wall-mounted. It is important to
check that the radio signal can be received before permanently mounting
both units.
b. The Outdoor Station
To achieve true temperature reading, avoid mounting the remote sensor in
direct sunlight. We recommend mounting the sensor on an outdoor north-
facing wall. Obstacles such as walls, concrete and large metal objects will
reduce the transmission range.
To wall-mount the sensor, fix the bracket on the wall using the three
screws. Fix the unit onto the bracket as shown.
7. Description of the LCD
a. Overview
Refer to the illustration on page 2 of this manual.
1
DST (Daylight Saving Time)
16
outdoor humidity
2
DCF77 radio signal
17
outdoor temperature and humidity HI / LO alarm
3
time
18
temperature scale
4
radio-controlled time icon
19
outdoor temperature
5
alarm on icon
20
general outdoor alarm
6
day of the week / time zone
21
weather forecast
7
date
22
weather tendency
8
indoor humidity
23
pressure HI alarm
9
indoor temperature and humidity HI / LO alarm
24
absolute or relative atmospheric pressure selection
10
indoor temperature
25
pressure LO alarm
11
temperature scale
26
atmospheric pressure with 24-hour history graph
12
indoor temperature and humidity alarm on
27
atmospheric pressure
13
outdoor sensor signal transmission
28
atmospheric pressure scale
14
MIN / MAX
29
atmospheric pressure alarm
15
dew point temperature
b. Weather icons
The four weather icons (sunny, partly cloudy, cloudy and rainy) represent the weather icons. These icons are
based upon change of atmospheric pressure.
sunny partly cloudy cloudy rainy
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Velleman WS1170 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Velleman WS1170 in the language / languages: English, German, Dutch, French, Spanish as an attachment in your email.

The manual is 1,57 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info