Operating Manual
Shutter module
LLUUXXOORR 440088 SS
408 0 100 (basic device)
LLUUXXOORR 440099 SS
409 0 100 (upgrade module)
11..00 DDeessiiggnnaatteedd uussee
22..00.. SSaaffeettyy nnootteess
LUXOR 408 S
LUXOR 409 S
The LUXOR shutter module controls shutters, awnings and blinds. It expands the
existing LUXOR range and is suitable for installation in houses, flats and offices
etc. The device should be properly installed in a control or distribution box.
Set the final position of the motors before starting up shutter module.
This prevents damaging the covering.
Keep the area of the system’s direction of travel clear.
Disconnect the system/covering from the power supply before carrying out
work on system/coverings.
The direction of travel must be visible during operation if the system is con-
trolled by the device.
Do not connect inputs in parallel.
309 442
DDaannggeerr ooff ddeeaatthh tthhrroouugghh eelleeccttrriicc sshhoocckk oorr ffiirree!!
Installation should only be carried out by a professional
electrician!
WWAARRNNIINNGG
P
S
S
P
Schirm
Schirm
33..00 CCoonnnneeccttiioonn aanndd iinnssttaallllaattiioonn
Do not route the COM line parallel to 230 V lines.
Can be extended to max. 16 devices inc. basic module.
Ensure correct polarity!
If the COM connection fails, the SET LED flashes continuously.
Use the following lines: EIB/KNX bus line type YCYM or Y(ST)Y or
telecommunication line J-Y(ST)Y
Connect both sides of the shielding to the minus bus terminal on the COM bus.
The COM line may be up to 100 m in length.
Always route the COM line separately from other lines
(separate cable).
P
S
S
P
DOWN push
button
UP push button
Diode module
907 0 367;
Can be instal-
led in any
direction!
IInnssttaallllaattiioonn ooff bbuuss lliinnee
LUXOR 400 + LUXOR 408 S
IInnssttaallllaattiioonn ooff iinnppuuttss
Do not connect inputs in parallel!
You can achieve the same effect through configuration (see 9.0 Group
functions/Assigning multiple outputs to one input).
Only connect one motor per channel!
If more than one drive is connected per channel, they must be decoupled via
relay controls.
Push button connection for group G1
(G3 on LUXOR 409 S):
Control voltage 230 V~
Push button connection for group
(G2 on LUXOR 409 S):
Control voltage 230 V~
Push button inputs I 1 to I 4
Control voltage 230 V~
Operating voltage 230 V~
+10 %/ -15 %.
Ensure correct polarity of
LL
and
NN..
IInnppuutt tteerrmmiinnaallss
SS
SS
With push button inputs
II
1 to
II
4, the push button connection for group G1 and
the push button connection for group applies: It is possible to connect diffe-
rent outer conductors/phases (full wave = UP, half-wave = DOWN).
1


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Theben LUXOR 409 S at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Theben LUXOR 409 S in the language / languages: English as an attachment in your email.

The manual is 1,04 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Theben LUXOR 409 S

Theben LUXOR 409 S User Manual - German - 28 pages

Theben LUXOR 409 S User Manual - German - 6 pages

Theben LUXOR 409 S User Manual - Dutch - 6 pages

Theben LUXOR 409 S User Manual - French - 6 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info