Operating Instructions
Power Peak
®
D7 EQ-BID
Order No.
8129
11
Select Order of the process
Charge
(for Li-xx bat-
teries)
The process is switched off if all the cell volta-
gesareadequatelybalanced,thedefined"TVC
voltage" is reached, and the charge current has
fallen to 10%. This is a charge process which
rapidly charges the battery, with a good com-
promise between cell balance and charged-in
capacity. The capacity charged in is higher than
that obtained with a "fast charge".
Charge
(for NiCd /
NiMH batte-
ries)
Battery is charged using the set charge para-
meters. Process terminates according to the
Delta-Peak method.
Automatic
(NiCd / NiMH
batteries only)
In "AUTOMATIC" mode the charger automa-
tically sets the optimum charge current. The
maximum charge current is defined by the
"Charge current" parameter in the "Memory
name" menu.
Discharge
In "Discharge" mode the battery is discharged
using the current defined in the "Discharge
current" parameter in the "Memory name" menu
(max. 40 W). The final discharge voltage is
defined by the "Discharge voltage" parameter.
Re-peak
(NiCd / NiMH
batteries only)
In "RE-PEAK" mode it is possible to define the
number of re-peaks (1 ... 3) using the "RE-PEAK"
parameter in the Mode Select menu. With old
NiCd / NiMH batteries, or packs which have
been in storage, this ensures that they really are
fully charged at the end of the charge process
(i.e. the mode compensates for early charge
termination). The defined number of "re-peaks"
is worked through in sequence. After every peak
the charger automatically waits for five minutes.
After this pause the next charge process starts,
and this continues until all "re-peaks" and the
"normal peak" have been completed.
Cycle
(NiCd / NiMH
batteries only)
In "CYCLE" mode a battery is alternately char-
ged, then discharged; or discharged, then char-
ged. This is designed to compensate for the
Memory Effect, allowing your battery to be used
again at full capacity.
Between the individual charge / discharge pro-
cesses a pause is inserted; the length of the
pausecanbeadjustedinthe"Pausetime"para-
meter in the "User settings" menu.
Storage
(Li-xx batteries
only)
The charger can bring Li-xx batteries to the
following voltages prior to storage (e.g. over the
Winter):LiPo: 3.8 V/C,LiIo: 3.7 V/C,LiFe: 3.3
V/C.Sincethebatterymayneedtobecharged
or discharged to achieve this, both the charge
current and the discharge current must be set
beforehand. Recommendation:
Use every six weeks when batteries are not in
use.
Fast charge
(Li-xx batteries
only)
The process is switched off if all the cell voltages
areadequatelybalanced,andthedefined"TVC
voltage" (in the "Memory name" menu) is rea-
ched. The charge current is not reduced. This is
a charge process which charges the battery very
rapidly, with a good compromise between cell
balance, charged-in capacity and charge time.
Balance
(Li-xx batteries
only)
The process is switched off if all the cell voltages
are adequately balanced, the defined "TVC
voltage" is reached (in the "Memory name"
menu), and the charge current has fallen to
10%. This is a charge process which produces
very well-balanced cells and optimum charged-
in capacity.
When you have set the mode, navigate to "CYCLE" and hold the
"START / ENT." button pressed in. The process begins, using the
mode you have selected.
Note:
Thepausebetweencyclescanbeadjustedinthe"Usersettings"
menu (see P. 10).
The following table explains the individual user selection options:
When used with NiCd and NiMH batteries, the Power Peak
®
D7
EQ-BID switches over to a trickle (maintenance) charge at the end
of the main charge process.
TheCC-CVchargeprocessconsistsofthreephases,andisused
for the following battery types: LiFe, LiIo, LiPo and Pb
1. In the CC (Constant Current) Phase the charge current is maintai-
ned at a constant level until the final charge voltage is reached.
2.ThisphaseisfollowedbytheCV(ConstantVoltage)phase,in
which the voltage is maintained at a constant level. The battery is
nowalreadychargedtoapproximately85-90%offullcapacity,
and the charge current is reduced further.
3.When98%capacityisreached(chargecurrent=capacity/10)
the cut-off melody sounds and the cut-off display appears on the
charger's screen. In practical terms the battery is fully charged,
and can be disconnected from the charger.
CC phase
Constant Current
CVphase
ConstantVoltage
1C
26


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Multiplex Power Peak D7 EQ-BID - 30 8129 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Multiplex Power Peak D7 EQ-BID - 30 8129 in the language / languages: English, German, French, Italian, Spanish as an attachment in your email.

The manual is 9,26 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info