The JA-80V LAN/PSTN line communicator - 7 - MKA51202
5.10. Initialization of GSMLink communication
After successfully connecting the communicator to the LAN network
913 should be entered to initialise communication to the
www.GSMLink.cz
server (the server will register the IP address of the
communicator).
To access the system remotely via the Internet it is necessary to
register it on www.GSMLink.cz
(after communication has been
initialised). To register the system (see 7.5) you will need the
communicator registration code, which is printed on the label which
you will find on the communicator board.
Note:
the communicator reports regularly to the GSMLink server to update
the communicator’s IP address in the server database (the period of
the regular reports is more frequent the more frequently GSMLink
access is used). If you try to access the alarm system via GSMLink
after the communicator’s dynamic IP address has changed, you can
be notified by GSMLink that it is necessary to wait for the next
regular communication from the system. To shorten this waiting time
you can enter the above sequence (913) on the system keypad
while in service mode or you can do it remotely by calling the
communicator from a phone, whose number was programmed for
this purpose (see the following text).
5.10.1. Tel. number to initialise GSMLink communication
GSMLink communication can be initialised remotely by calling (ringing)
from a phone number which can be programmed by:
914 xx...x 0 where xx...x = phone number (max. 20 digits)
Notes:
After the first ring from the above programmed number the
communicator will report to GSMLink to update its IP address,
this remote way of initialisation is only possible if the phone line
used by the communicator supports CLIP caller ID recognition).
Factory default setting: erased
5.11. Tx SMS center telephone number
To send SMS by CLIP protocol via the telephone line it is necessary to
program the Tx SMS center telephone number by:
942 xx...x 0 where xx...x = Tx SMS center tel. number
Note:
Contact your telephone line provider to learn the Tx SMS center tel.
number.
Factory default setting: erased
5.12. Rx SMS center telephone number
To receive SMS by CLIP protocol via the telephone line it is necessary
to program the Rx SMS center telephone number by:
942 xx...x 0 where xx...x = Rx SMS center tel. number
Note:
Contact your telephone line provider to learn the Rx SMS center tel.
number,
check also how to activate delivery of the SMSes in text form (some
providers convert SMS text into voice messages).
Factory default setting: erased
5.13. Testing reporting to an ARC
To test reporting to an ARC enter:
961a where a = ARC number (1 or 2)
Note:
The event code “Communication test” (ec=31) will be sent to the ARC.
The green LED flashes while the report is being sent, if the red LED
goes off it indicates that the report to the ARC was unsuccessful.
5.14. Testing calls to a phone number
To test that the communicator is capable of calling the phone numbers
programmed into its memories enter:
962M where M is the phone number memory 1 to 8
If memory M contains a phone number, this number will be called and
if the phone call is answered, there will be an acoustic signal.
5.15. Remote programming by the SMS instruction
Instruction PRG can be used to send programming and operating
sequences to the alarm system:
code_PRG_seq,seq,seq...
where:
code is valid access or service code (e.g. 8080 or 1234)
_ space
seq programming sequence usually set via the keypad
Note:
In the sequence can be used characters 0 to 9, and #)
When the valid instruction is received, communicator simulates
entering the keys on the keypad, comma in the SMS is taken as a
pause in the sequence entering
System must be unset and switched to the service mode
The number of sequences in one SMS is limited by the maximum size of
the SMS in the GSM network.
Example: by sending SMS 8080 PRG
08080,201,# the exit delay will
be set to 10s
5.16. Triggering LAN re-login
After entering
935 the communicator will log out of the LAN network and
then re-log in (DHCP updates).
5.17. Communicator reset
Entering 98080 returns the communicator to its factory default settings and
texts, erases all telephone numbers and disables reporting.
5.18. Automatic DHCP
The factory default settings in the communicator expect automatic
DHCP in the LAN network. If you need to enter the network
parameters manually, the automatic DHCP should be disabled with
this sequence and network parameters should be entered manually by
the following sequences before the communicator is connected to the
LAN network.
9300 DHCP disabled
9301 DHCP enabled
Factory default setting: enabled
5.19. Communicator IP address
If DHCP is disabled (see 5.18) program the communicator IP address
by:
931 xxx xxx xxx xxx
where:
xxx…x is IP address
Example: if the IP address is 192.168.1.23 enter:
931 192 168 001 023
Factory default setting: 192.168.001.211
5.20. Network mask
If DHCP is disabled (see 5.18) program the network mask by:
932 xxx xxx xxx xxx
where:
xxx…x is the network mask
Example: if the network mask is 255.255.255.0 enter:
932 255 255 255 000
Factory default setting: 255.255.255.000
5.21. Network gateway address
If DHCP is disabled (see 5.18) program the network gateway by:
933 xxx xxx xxx xxx
where:
xxx…x is the gateway address
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Jablotron JA-80V at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Jablotron JA-80V in the language / languages: English as an attachment in your email.

The manual is 0,15 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Jablotron JA-80V

Jablotron JA-80V User Manual - Dutch - 11 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info