555056
8
Zoom out
Zoom in
Previous page
1/10
Next page
The JA-80V LAN/PSTN line communicator - 8 - MKA51202
Example: if gateway address is 192.168.33.1 enter:
933 192 168 033 001
Factory default setting: 192.168.001.001
5.22. DNS IP address
If DHCP is disabled (see 5.18) program the network DNS IP address
by:
934 xxx xxx xxx xxx
where:
xxx…x is the DNS address
Example: if the DNS address is 192.168.33.1 enter:
933 192 168 033 001
Factory default setting: 192.168.001.001
5.23. ARC phone numbers / IP addresses
Events can be reported to up to 2 ARCs (which can be independent or
ARC2 can work as ARC1’s backup). The communicator reports to
ARC1 via a LAN network using IP CID protocol and to ARC2 via the
phone line using CID protocol. This sequence serves to enter an
ARC’s main and backup IP addresses / phone numbers:
Main: 01 a xx....x 0
Backup: 02 a xx....x 0
where:
a 1=ARC1, 2=ARC2
xxx...x IP address and port for a=1 – entry format example:
01 2 8 192 168 001 123 08080 0
where 8 (auto-converts to #) signifies an IP address
which must have 12 digits and must be followed by the 5
digits of the port number (no separators)
tel. number (max. 20 digits) for a=2
To erase a tel. number / IP address enter: 01a0 or 02a0
If numbers / IP addresses are erased there will be no reporting to that
particular ARC
Notes:
the communicator first tries to send data to the main number /
address, if it is not successful it tries the backup
IP CID is a fast protocol and it also allows very frequent checking
of communication reliability with the ARC (e.g. every 5 minutes)
Contact ID protocol can be used with ARCs linked by standard
telephone lines (if they support Contact ID)
If your ARC does not allow IP CID protocols, please contact a
Jablotron distributor for details on how to update your ARC.
Another way of backing up communication to an ARC is a calling
report to a particular number (see 5.3). This way up to 8 groups of
events can be reported to an ARC. For this the ARC needs 8 phone
lines which can recognize caller ID. By calling a particular ARC tel.
number the communicator is communicating what happened (the
kind of event). The ARC can recognize what happened by knowing
which telephone line is being rung.. By caller ID recognition it also
knows what installation is reporting. The ARC does not answer the
incoming calls on these telephone lines, so this simple kind of
communication is free of charge. By using this method the ARC does
not send any confirmation back to the communicator that the report
was successfully received.
Factory default setting: all tel. numbers / IP addresses erased
5.24. Installation (alarm system) ID for ARC use
The installation’s ID number which is sent to an ARC with every report
can be programmed by:
03 a zz..z 0
where:
a 1=ARC1, 2=ARC2
zz..z installation ID number, max. 8 characters (0 to 9 and
1=A to 6=F - hexadecimal number)
Factory default setting: 0000 for both ARCs
5.25. Selecting the ARC communication protocol
To select the required communication protocol enter:
04 a x
where:
a 1=ARC1, 2=ARC2
x 0=Contact ID, 1= IP CID
Notes:
IP CID is the fastest of the above protocols and it also allows very
frequent checking of communication reliability with the ARC (e.g.
every 5 minutes)
Contact ID protocol can be used with ARCs linked by standard
telephone lines (if they support Contact ID)
If your ARC does not allow IP CID protocol, please contact a
Jablotron distributor for details on how to update your ARC.
Factory default setting: Contact ID for both ARCs
5.26. Selection of events to report to ARCs
The system recognizes 32 different types of events - see the following
table. This sequence allows you to select which events are reported to
which ARC.
05 a ec x
where a 1 = ARC1, 2 = ARC2
ec event code 01 to 32
x 0 = no report, 1 = report
Factory default setting: all events are reported
ec Event
01 Intruder alarm - instant
02 Intruder alarm - delayed
03 Fire alarm
04 Panic alarm
05 Number of permitted incorrect code-entries
exceeded
06 Alarm triggered during control panel power-up
07 Tamper alarm
08 End of tamper alarm
09 End of alarm indication
10 Alarm cancelled by user
11 Setting
12 Unsetting
13 Partial setting
14 Codeless setting
15 External communication fault
16 External communication restored
17 Fault
18 Fault no longer present
19 Mains dropout longer than 30 minutes
20 Mains dropout
21 Mains restored
22 Discharged battery
23 Battery OK
24 Switching to Service Mode
25 Leaving Service Mode
26 PGX ON/OFF
27 PGY ON/OFF
28 Radio communication jamming present
29 Internal communication fault
30 Internal communication restored
31 Communication test
32 Unconfirmed alarm
Besides the events listed above, the communicator also reports some
events which are not selectable here (e.g. the annual inspection
request if enabled in the control panel = CID 1393)
5.27. Defining the delay before data is resent to an ARC
The communicator tries to send reports to the main number / IP
address, and if unsuccessful it then tries the backup number. If still
unsuccessful, it then tries to re-send the data to both the ARCs again
as before, but after a period defined by:
06 a t
where: a 1 = ARC1, 2 = ARC2
t is the period: 0=immediately, 1 to 9 = 1 to 9 minutes
Factory default setting: 1 min. for both ARCs
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Jablotron JA-80V at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Jablotron JA-80V in the language / languages: English as an attachment in your email.

The manual is 0,15 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Jablotron JA-80V

Jablotron JA-80V User Manual - Dutch - 11 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info