555054
4
Zoom out
Zoom in
Previous page
1/6
Next page
User instructions of JA-60 "Comfort" - 4 - MDY51415
5.2. Voice message recording (sequence: 8 0)
Press shortly key 8 then press key 0 and hold it pressed while talking into the control panel’s front grid (max. 20 seconds). After
releasing the 0 key, the message will play back. The message is stored in non-volatile memory and can be changed when ever you
want to by repeating the above steps. Make the message clear and brief. The dialer repeats the message to each called number for 40
seconds.
It is possible to split the voice message into two different messages (10 seconds each). Depending on the setting in programing
mode, a particular message will be sent under different situations.
If you want to record two messages: press shortly key 8 and then press key 1 and hold it pressed while recording the first message.
To record the second message press shortly key 8 then press key 2 and hold it pressed while talking into the control panel’s front grid.
5.3. Telephone dialer testing (sequence: 8 9)
Enter 89 and the dialer will call the programmed numbers once. If SMS transfer is set, then is realized too. You will hear the telephone
line signals from the control panel built in speaker during the test (if the dialer is triggered by an alarm in normal operation, it will call
silently). Testing can be terminated with the N key.
If two different voice messages were recorded, then use sequence 88 to test the sending of the first message and 89 to test the
sending of the second message.
Note: if you enter 89 in the user mode when there is an incoming call on the telephone line, the dialer will answer the call. This is the
way to allow the installer to dial in to your system from his computer, even if the dialer was programmed to the "never answer" mode
during installation. But even with this manual approval the installer must know the digital dialer access code (8 digits) to be able to
establish connection. This access code must be programmed during the installation (factory default setting is 00000000).
6. Real time and date setting (sequence: 4 hh mm dd MM YY)
The control panel has a built in real time clock. All events are stored to the event memory including the time of the event.
At first open the “User mode” by the sequence: F0 + master code. The “User mode” is notified by the letter “U” on the display.
The clock can be set by the sequence: 4 hh mm dd MM YY
hh -> hours (24 hr. cycle)
mm -> minutes
dd -> day
MM -> month
YY -> year
Example: on Jun. 30 2005 at 17:15 enter: 4 17 15 30 06 05
7. Enrollment of the control panel to a UC-2xx or to a master control panel
The control panel can send wireless data to output modules UC–216, UC–222 and UC-260. It can also work as a subsystem of another
JA-65 or JA-60 control panel.
Open the “User mode” of the control panel by the sequence: F0 + master code. The “User mode” is notified by the letter “U” on the display.
Enter the enrolling mode of the UC receiving device and then enter 299 and the control panel will generate the enrollment signal.
If you want to enroll a subsystem to your control panel, enter the enrolling mode on the MASTER control panel (see 12.1.) and then
enter sequence 299 in the programming mode of the sub control panel.
If the system is split, the sub control panel enrolls to the common shared section.
8. Automatic arming / disarming setting
The control panel can automatically arm and disarm for a requested period of a day. Up to ten instructions (time & action) can be
programmed in the period of one day.
Open the “User mode” of the control panel by the sequence: F0 + master code. The “User mode” is notified by the letter “U” on the display.
To set the action use the sequence: 64 nahhmm
where: n = instruction number from 0 to 9
a = action (see the actions' table)
hh = hours (from 00 to 23)
mm = minutes (from 00 to 59)
Notes:
If any automatic action is selected, it will be preformed everyday in the programmed time,
following the internal control panel clock (see 12.27.).
The automatic arming and disarming can be overridden manually anytime (by an user code or a remote control)
actions' table
a no splitting split system
0 no action no action
1 arm all arm all
2 disarm disarm all
3 partial arming arm A
4 partial arming arm B
5 disarm disarm A
6 disarm disarm B
If the control panel is in the requested arming mode before the action time, performance of the programmed action will not change the arming
To clear the action is not necessary to edit all the time statement. It is enough to set “0” for appropriate action (64 n 0).
Example: to program an automatic complete arming of the system at 21:15 everyday enter: 64 0 1 21 15
Factory default setting: all instructions are set for no action
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Jablotron JA-60 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Jablotron JA-60 in the language / languages: English as an attachment in your email.

The manual is 0,17 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Jablotron JA-60

Jablotron JA-60 Additional guide - English - 1 pages

Jablotron JA-60 Installation Guide - English - 34 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info