12204
8
Zoom out
Zoom in
Previous page
1/8
Next page
1-1-32 Kamiminami, Hirano-ku, Osaka 547-0003, Japan
A-6496X-1EX-w
Printed in China
© 2006 Icom Inc.
Transmitting DSC calls (continued)
DD
Transmitting a position report reply call
PPOOSS RReeppoorrtt RReeppllyy
” item appears after a position report
call is received.
q Select and enter “
PPOOSS RReeppoorrtt RReeppllyy
” in the DSC
menu.
w Select and enter the desired individual address.
e Push [ENT] to transmit the position report reply call.
DD
Transmitting a polling request call
q Select and enter “
PPoolllliinngg RReeqquueesstt
” in the DSC
menu.
w Select and enter the desired individual address.
e Push [ENT] to transmit the polling request call.
r Push [CLR] to return to the previous indication before en-
tering the DSC menu.
Even if [CLR] hasn’t been pushed, the display automatically
returns to the previous indication after 2 sec. of inactivity.
DD
Transmitting a polling request reply call
PPoolllliinngg RReeppllyy
” item appears after a polling request call
is received.
q Select and enter “
PPoolllliinngg RReeppllyy
” in the DSC menu.
w Select and enter the desired individual address.
e Push [ENT] to transmit the polling request call.
DSC Set mode (continued)
After entering an 8-digit ID code, push [ENT] or [16•9] to enter
the ID name.
• 1st digit ‘0’ is xed for a group ID.
e After inputting, push [ENT] to program.
r Push [CLR] or select “Exit” in the set up menu then push
[ENT].
• Returns to the DSC menu.
• Repeat again to return to the normal operation condition.
DD
Deleting Individual ID/Group ID
q S
elect and enter “
DDEELL::IINNDDVV IIDD
” or “
DDEELL::GGrroouupp IIDD
in the set up menu.
w Select the desired ID name for deleting.
e Push [ENT] to delete the address ID and return to the set
up menu.
r Push [CLR], or select “
EExxiitt
” in the set up menu then push
[ENT].
• Returns to the DSC menu.
• Repeat again to return to the normal operation condition.
DD
Offset time
q S
elect and enter “
OOffffsseett TTiimmee
” in the set up menu.
w Rotate [SELECTOR] to set the offset time from the UTC
(Universal Time Coordinated) time.
Push [16•9] or [CH/WX] to move the cursor forward or
backward, respectively.
• Push [CLR] to cancel and return to the set up menu.
e Push [ENT] to program and return to the set up menu.
DD
MMSI code check
The 9-digit MMSI (DSC self ID) code can be checked.
q S
elect and enter “
MMMMSSII CChheecckk
” in the set up menu.
w Check the 9-digit MMSI (DSC self ID) code.
e Push [CLR], or select “
EExxiitt
” in the set up menu then push
[ENT].
• Returns to the DSC menu.
• Repeat again to return to the normal operation condition.
DD
Automatic acknowledgement
q S
elect and enter “
AAuuttoo AACCKK
” in the set up menu.
w T
urn the
automatic acknowledgement function ON or OFF
.
e Push [ENT] to set the condition.
• Push [CLR] to cancel and return to the set up menu.
DD
NMEA Output
When receiving position acknowledgment, the transceiver out-
puts it to the external equipment via the NMEA connector.
q S
elect and enter “
NNMMEEAA OOuuttppuutt
” in the set up menu.
w Select the NMEA Output function.
e Push [ENT] to set the condition.
• Push [CLR] to cancel and return to the set up menu.
• List Station: Outputs the position data from the specified
vessels listed on the DSC individual ID screen.
All Station : Outputs the position data from all vessels.
OFF : Does not output any position data to external
equipment.
¤5 Received messages
The transceiver automatically stores up to 20 distress mes-
sages and 20 other messages. The messages can be used as
an assistance to the logbook.
q Select and enter “
RReecceeiivveedd CCaallllss
” in the DSC menu.
w Select and enter “
DDiissttrreessss
” or “
OOtthheerr
.”
e Select and enter the desired message.
Messages which are blinking have not been read.
r Rotate [SELECTOR] to scroll in the message.
t Push [CLR] to exit or push [CLR] for 1 sec. to delete the
displayed message and return to the DSC menu.
¤6 DSC Set mode
q Select and enter “
SSeett uupp
” in the DSC menu.
w Se
lect and enter the desired item.
e Select and enter the desired setting or condition.
Push [CLR] to cancel before pushing [ENT].
r Push [CLR], or select “
EExxiitt
” in the set up menu then push
[ENT].
• Returns to the DSC menu.
• Repeat again to return to the normal operation condition.
DD
Programming Individual ID/Group ID
q S
elect and enter “
AAdddd::IINNDDVV IIDD
” or “
AAdddd::GGrroouupp IIDD
in the set up menu.
w Rotate [SELECTOR]
to s
et the individual ID and ID name
(or group ID and ID name).
• Push [16•9] or [CH/WX] to move the cursor forward or back-
ward, respectively.
• Push [CLR] to cancel and return to the set up menu.
• “
FFuullll IIDD
” appears when all of the DSC address IDs are al-
ready set.
[For individual ID]
After inputting the 9-digit MMSI number, push [ENT] or [16•9]
to enter the ID name.
• 1st digit must not be ‘0’ for a individual ID.
[For Group ID]
The group ID is a unique number that you create for your
group. The ID name is an associated text name for that group.
CLEAN THE HM-162B/SW THOROUGHLY WITH FRESH
WATER after exposure to water including salt water, oth-
erwise, the keys and switch may become inoperable due to
salt crystallization.
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Icom HM-162B SW at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Icom HM-162B SW in the language / languages: English as an attachment in your email.

The manual is 0,17 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info