5. Probe LED Speci fica tion s
Waveleng th Radiant Power
RED 66 0± 2n m 1.8 mW
IR 94 0±10nm 2.0mW
6. Po wer Requ irements
Two AAA al kaline B atteries
Powe r con sumpt ion: Less tha n 30mA
Batte ry Life: Two AAA 1.5 V, 800mA h a lkaline batte ries cou ld be continuously ope rated a s long a s 28 hou rs.
7. Env ironm ent Requ irements
Ope ration Te mpe rature: 5
~40
Sto rage Tempe ratu re: -20
~+ 55
Ambi ent Humidity: ≤ 80% no condensati on i n oper atio n; ≤ 93% no c ondensation i n s tor age
Atmosphe re p ressu re: 86kP a~106k Pa
8. Equ ipm ent Response Time
As shown in the following figure.
Response t ime of s lower a verage is 12. 4s.
9. Classi fic ation
Acco rding to the t ype of p rotect ion aga inst e lect ric shoc k: INTERNALL Y POWERED EQUIPMEN T;
Acco rding to the deg ree of p rotect ion aga inst e lectric sho ck: TYPE BF APPLIED PAR T (The app licat ion pa rt is rubbe r inside of the
Pulse Oximete r);
Acco rding to the deg ree of p rote ction aga inst ing res s of wate r: IPX1
Acco rding to the mode of ope rat ion : CONT INU OUS OPE RATIO N
FCC Dec larati on
This dev ice co mplies with Part 15 of the FCC Rules. Ope rat ion is sub ject to the fo llowing t wo cond itions:
(1) This dev ice may not cause ha rmfu l inte rfe rence, and
(2) This de vice must accept any inte rfe rence received, inc lud ing inte rfe rence that may cau se undes ired ope rat ion.
Plea se ta ke attent ion that changes or mod ificat ion not expressly app roved by the pa rty respon sible fo r co mplian ce cou ld void the
user’s authority to oper ate the equipm ent.
Note: This product has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to prov ide reasonab le protect ion aga inst ha rmfu l inte rfe rence in a res ident ial insta llat ion. This
p
roduct gene rates, uses, and can rad iate rad io frequency ene rgy and, if not insta lled and used in acc ordan ce with the inst ructions,
may cause ha rmfu l inte rfe rence to rad io commun icat ions. Howeve r, the re is no gua rantee that inte rfe ren ce will not occu r in a
parti cular ins tall ati on. If this pr oduct does c ause harm ful i nter fer ence to r adio or televisi on r ecepti on, whi ch can be determi ned by
turni ng the equipm ent off and on, the user is en cou raged to try to correct the inte rfe ren ce by one or more of the followi ng m easur es:
—Reorient or relocate the receiving antenna.
—Inc rea se the sepa rat ion bet ween the equ ipment and receive r.
—Connect the equipment into an outlet on a circu it d iffe rent f ro
m that to which the rece iver is conne cted.
—Consult the dealer or an experienced radio/TV technician for help.
Dec laration
Guidance and Manu fac turer’s declara tion – elec trom agn etic e mission s-For all EQUIPMEN T a nd SYSTEM S
Guidance and Manu fac turer’s declara tion - elec trom agn etic e missi on
The SMG 01 Pulse Ox imete r is intended fo r use in the electromagnet ic env iron ment spe cified be low . The cu sto mer or the user
of SMG01 Puls e Oxim eter shoul d assur e that i t is u s ed i n such an envir onm ent.
Emission t est Compliance E lectr oma gnet ic Envir onment – guid ance
RF emissions CI SPR 11 Gr oup 1 T he SMG01 Pulse Oximeter uses RF energy only for its
inte rna l fun ction. The refo r e, its RF emiss ion s are very low
and are not likely to c ause any i nter fer ence in near by
electron ic equ ipment .
RF emissions CI SPR 11 Class B
Harmonic emissions
IEC 6100 0-3-2
Not Applicable
Voltage f luctuat ions/ f licker e miss ion s
IEC 6100 0-3-3
Not Applicable
The pu lse Oximete r (SMG 01) is su itab le fo r use in all
establishm ents, incl udi ng domestic es tablishm ents and
those dir ectly connec ted to the public low -vol tage power
supply network that supplies bu ilding s used fo r do mestic
pur poses.
Guidance and Manu fac turer’s declara tion – elec trom agn etic immun ity-For all EQUIPMEN T a nd SYSTEMS
Guidance and Manu fac turer’s declara tion - elec trom agn etic immun ity
The SMG 01 Pulse Ox imete r is intended fo r use in the electromagnet ic env iron ment spe cified be low . The custo mer or the user
of the SMG01 Puls e Oxim eter shoul d as sur e that i t i s used i n suc h an envir onm ent.
Immun ity tes t IEC 60601 tes t le vel Co mpliance
Level
Elec trom agn etic Env ironm ent – gu idance
Elect rostat ic
Discharge (ES D)
IEC 6100 0-4-2
+/- 6kV contact
+/- 8k V a ir
+/- 6kV contact
+/- 8k V a ir
Floo rs shou ld be wood, conc rete or c eramic tile. If
floo r are covered with synthet ic mate rial, the relat ive
humidi ty s houl d be at l eas t 30%.
Powe r frequency (50/60
Hz) magnetic field
IEC 6100 0-4-8
3A/m 3A/m Powe r frequenc y magnet ic fields shou ld be at levels
characteristics of a typical location in a typ ical
comm ercial or hospital environment.
Guidance and Manu fac turer’s declara tion – elec trom agn etic immun ity-
For all EQUI PMENT a nd SYST EMS that are not LIFE -SU PPORT ING
Guidance and Manu fac turer’s declara tion - elec trom agn etic immun ity
The SMG 01 Pulse Ox imete r is intended fo r use in the electromagnet ic env iron ment spec ified be low. The custo mer or the user
of the SMG01 Puls e Oxim eter shoul d assur e that i t is u s ed i n suc h an envir onm ent.
Immun ity
tes t
IEC 60601
tes t le vel
Compliance
Level
Elec trom agn etic Environm ent – gu idance
Radiated
RF
IEC
61000-4-3
3 V/m
80 MHz to
2.5 GHz
3 V/m
Portab le and mob ile RF commun icat ions equ ipment shou ld be used no closer
to any part of the Pulse Oxim eter ( SMG01), incl udi ng c ables, than the
recommended sepa rat ion distan ce ca lculated from the equat ion app licab le to
the fr equency of the tr ansmi tter.
Recomm ended separation distance
80 MHz to 800 MHz 800 MHz to 2.5 GHz
Whe re P is the max imum ou tpu t powe r rating of the trans mitter in wa tts (W)
accordi ng to the t rans mitte r manufa ctu rer and d is the recommended
separation distance in mete rs (m).
Field strength s from fixed RF transm itte rs, as dete rm ined by an
electromagnet ic site su rvey
a
, shou ld be less than the complian ce leve l in
each fr equency r ange.
b
Inter fer ence m ay occur in the vicinity of equipment marked with following
sym bol:
NOTE 1 At 80 MHz and 800 MHz , the higher frequency range applies.
NOTE 2 These guidelines may not apply in all situations, Electromagnetic propagation is affected by absorption and reflect ion
structures, objects and people.
a Field strengths from fixed transmitters, such as base station for radio (cellular/cordless ) telephones and land mobile radios,
amateu r rad io, AM and FM rad io broad cast and TV broad cast cannot be pred icted theo ret ica l ly with accu rac y. To asse ss the
elect romagnet ic en viron ment due to fixed RF trans mitte rs, an electromagnet ic site su rvey shou ld be con side red. If the
measu red field strength in the locat ion in wh ich the Pulse Oximete r (SMG 0 1) shou ld be obse rved to ve rify normal ope rat ion. If
abnormal per form ance is obser ved, additi onal m easurem ents may be neces sary, such as r eori enti ng of the rel ocati ng the Pul se
Oximeter (SMG 01).
b Over the frequen
cy range 150 kHz to 80 MHz, fields strengths should be less than 3 V/m
Recomm end ed se para tion dis tances betwee n po rtable and mobile RF c ommunica tions equ ipm en t a nd
the EQUIPME NT or SYSTEMS - For all EQUIPMEN T a nd S YSTEMS that are no t LIFE-SUPPO RTIN G
Recomm end ed separation distances between
portab le and mobile RF c ommunicati ons e qui pment a nd Pulse Oxi meter (SMG 01)
The Pulse O ximete r (SMG01) is intended for use in electromagnetic environment in which radiated RF disturbances are
controlled. The customer or the user of the Pulse Oximete r (SMG01) can he lp preven t elec tromagne tic inte rfe rence by
mainta ining a minimum distance between po rtab le and mob ile RF commun icat ion s equ ip ment (tran smitte rs) and the Pulse
Oximeter (SMG01) as rec ommended be low, a cco rding to the max imum output po wer of the commun icat ions equ ipment.
Separation dis tance acc ording to frequ ency of transmitter (m ) Rated maximum ou tpu t
pow er of t ransmitt er (W)
80 MHz to 800 MHz
800 MHz to 2.5 GHz
0.01 0.1167 0.2334
0.1 0.3689 0.7378
1 1.166 7 2.333 4
10 3.689 3 7.378 6
100 11.6667 23.3334
For transm itte rs rate d at a max imum output powe r not listed above, the recommended sep arat ion distan ced in meters (m) can
be estim ated usi ng the equati on applic able to the fr equency of the tr ansmi tter, w here P is the m aximum output power r ati ng of
the tr ansmi tter i n w atts (W) according to the transmitter manufacturer.
NOTE 1 At 80 MHz and 800 MHz , the separation distance for the higher frequency range applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and refle ction
from structu res, ob jects and peop le.
Possible Pr oblem s and Soluti ons
Proble ms Possi ble reas on So lution
SpO
2
or PR can not
be s how n normally
1. Finge r is not inserte d co rrect ly
2. Pat ient ’s SpO
2
val ue is too low to be m easured
1. Retry by inserting the f inge r
2. T her e i s ex cessiv e illumi nation
3. Try some more t imes. If you can make sure no
prob lem ex ist in the p roduc t, plea se go to a
hospi tal t imel y for e x act di agnosis.
SpO
2
or PR is sho wn
uns tably
1. Finge r might not be inserted deep enoug h .
2. Excessive pat ient move men t
1. Retry by inserting the f inge r
2. Be calmnes s
The oximete r cannot
be power ed on
1. No batte ry o r low po wer of batte ry
2. Batte ries might be insta lled incorrectly
3. The oximete r might be da mage d
1. Plea se rep lace batte ries
2. Please reinsta ll the batte ries
3. Plea se conta ct w ith local custo mer se rvice
centre
Indi cati on lamps a re
suddenly off
1. The p rodu ct is auto mat ically po wered off when no
signal is detected longer than 8 seconds
2. The batte ry po wer is too low to work
1. Normal
2. Replace the batteries
“Error3” or
“Error4” is disp layed
on scr een
1. Err 3 mean s the red e mission LED is da mage d
2. Err 4 mean s the inf ra-red e miss ion L ED is da mage d
1. Chec k the red e mission L ED
2. Chec k the inf ra-red e miss ion L ED
Error6
Err 6 means the s creen is fa ilure Plea se conta ct with local custo mer service c entre
“Error7” is displayed
on scr een
Err 7 mean s a ll the e mission L ED o r recept ion d iode is
dam aged.
Plea se conta ct with local custo mer service c entre
Sym bol De finiti ons
Symbo l D efinition Symbo l Definition
Type BF appli ed part.
Attent ion
Protected aga inst d ripp ing wate r.
SpO
2
﹪ Oxygen satur ati on
PR bpm
Pulse rate (BPM )
Low power i ndi cati on
No SpO
2
Alarm
SN
Serial N o.
Sto rage tempe ratu re and relat ive
humidity
Follow inst ruction fo r us e
Manufactu rer’s info rmat ion
Date of Manufacture
Bluetooth ind icat ion
Indic ate the si gnal i s not stable
Notes:
1. The illus trations use d i n this manual may differ sligh tly from the appeara nce of the ac tual produ ct.
2. The s peci fica tions are subjec t to c hange withou t pri or no tice .
Baros GmbH
Kleine Düwelstr. 21
30171 Hannover
0123