Page 129FT-991 OperaTing Manual
049 AM DATA GAIN
Function: Sets the level of the AM signal input when
045 AM MIC SELECT
” is set to “
DATA
”.
Available Values: 0 - 100
Default Setting: 50
050 CW LCUT FREQ
Function: Sets the low-frequency cutoff audio filter in
CW mode.
Available Values: OFF/100Hz - 1000Hz (50Hz/step)
Default Setting: 250Hz
Description: This is the low-frequency cutoff audio lter
in CW mode.
The cutoff frequency can be set at 50 Hz increments
between 100 Hz and 1000 Hz.
051 CW LCUT SLOPE
Function: Sets the slope of the low-frequency cutoff au-
dio lter in CW mode.
Available Values: 6dB/oct / 18dB/oct
Default Setting: 18dB/oct
Description: Selects the slope of the low-frequency cut-
off audio lter in CW mode.
052 CW HCUT FREQ
Function: Sets the high-frequency cutoff audio lter in
CW mode.
Available Values: OFF/700Hz - 4000Hz (50Hz/step)
Default Setting: 1200Hz
Description: This is the high-frequency cutoff audio l-
ter in CW mode.
The cutoff frequency can be set at 50 Hz increments
between 700 Hz and 4000 Hz.
053 CW HCUT SLOPE
Function: Sets the slope of the high-frequency cutoff au-
dio lter in CW mode.
Available Values: 6dB/oct / 18dB/oct
Default Setting: 18dB/oct
Description: Selects the slope of the high-frequency cut-
off audio lter in CW mode.
054 CW OUT LEVEL
Function: Sets the level of the CW signal output from
the
RTTY/DATA
jack.
Available Values: 0 - 100
Default Setting: 50
055 CW AUTO MODE
Function: Enables/disables CW keying while operating
on SSB.
Available Values: OFF/50M (50MHz)/ON
Default Setting: OFF
Description:
OFF:
Disables CW keying while operating on SSB.
50M:
Enables CW keying while operating SSB on 50
MHz (but not HF).
ON:
Enables CW keying while operating SSB on all
TX bands.
056 CW BK-IN TYPE
Function: Sets the CW brake-in function.
Available Values: SEMI/FULL
Default Setting: SEMI
Description: Selects the CW brake-in function.
SEMI:
A brief delay is provided after the CW keying op-
eration, before the transceiver returns to receive
mode.
The receiver recovery time may be changed us-
ing MENU “
057 CW BK-IN DELAY
”.
FULL:
The transceiver immediately returns to receive
mode after every CW key-up (QSK mode).
057 CW BK-IN DELAY
Function: Sets the CW delay time.
Available Values: 30msec - 3000msec (10msec/step)
Default Setting: 200msec
Description: In semi break-in mode, this setting deter-
mines the delay time before returning to receive
mode after the CW keying operation.
The delay time can be changed in 10 msec steps be-
tween 30 msec and 3000 msec.
058 CW WAVE SHAPE
Function: Selects the CW carrier wave-form shape (rise/
fall times).
Available Values: 2ms/4ms
Default Setting: 4ms (msec)
Description: Sets the rise and fall times of the keying
envelope in CW mode (transmit waveform).
Menu MoDe
131


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Yaesu FT-991 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Yaesu FT-991 in the language / languages: English as an attachment in your email.

The manual is 30,58 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info