The Spectrum Scope Monitor allows viewing of operating activity on frequencies above
and below your current operating frequency in the VFO mode, or viewing of memory
channel activity on the current memory group when in the Memory mode. When the Spec-
trum Scope Monitor is activated, the display indicates the relative signal strength on chan-
nels immediately adjacent to the current operating frequency.
Using the Spectrum Scope
1. Set the transceiver to the VFO mode in the desired band, or within the desired memory
group.
2. Press the
[
FUNC
]
key momentarily, then rotate the SELECT knob, as needed, until
Multi Function Row “h”
[
SCOP, WID, STEP
]
appears on the display.
3. Press the
[
A
](
SCOP
)
key momentarily to engage the Spec-
trum Scope.
4. When the Spectrum Scope is in operation, the relative
signal strength of stations on channels immediately adja-
cent to the current frequency will be indicated on the dis-
play.
5. While the Spectrum Scope is activated in the VFO mode, press the
[
B
](
WID
)
key to
change the visible bandwidth. Available selections are ±10 (default), ±15, and ±63 chan-
nels. Press the
[
C
](
STEP
)
key to change the channel step resolution. Available selec-
tions are shown bellow.
Mode Channel Steps
(
kHz
)
CW, SSB, DIG 1.0 / 2.5 / 5.0
AM 2.5 / 5.0 / 9.0 / 10.0 / 12.5 / 25.0
FM, PKT 5.0 / 6.25 / 10.0 / 12.5 / 15.0 / 20.0 / 25.0 / 50.0
While the Spectrum Scope is activated, press and hold in the
[
B
]
key for one second
to change the Sweep mode. This allows you to switch between “Single Sweep” and
“Continuous Sweep (default)” scanning modes.
When the Spectrum Scope mode is in the “Single Sweep” mode, press and hold in
the
[
A
]
key for one second to restart the Sweep.
While the Spectrum Scope is activated, press and hold in the
[
C
]
key for one second
to enable the “Meter Peak Hold” feature. This will show you the maximum signal
level recorded on a particular channel.
6. To disable the Spectrum Scope, press the
[
A
](
SCOP
)
key once more.
The receivers audio output and S-meter are disabled when using the Continuous
Sweep.
SPECTRUM SCOPE MONITOR
82


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Yaesu FT-857D at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Yaesu FT-857D in the language / languages: English as an attachment in your email.

The manual is 4,64 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info