3. User interface
A. LED color meaning
On the product, there are 2 Led indicators (1) and (2).
- (1):
o Red fix: Pump is activated
o Blue fix: Dehumidifier is activated (humidity funtion activated and default detected)
o Red/Blue blink: Pump and Dehumidifier are activated
- (2):
o Red fix: system in heating
o Blue fix: system in cooling
o Green fix: your system is in RF Link mode (waiting for RF link of BT-M6Z02-RF)
o Green flash: BT-HCM02-RF has received a RF frame from the BT-M6Z02-RF
o Green blink: RF error or BT-HCM02-RF not linked
B. Buttons
There is a button (3) at the right side of the product.
It is used to go into RF Link mode, to do this:
o Press it for 5 seconds
o Led (2) turns Green fix
o Now product is ready for a RF link with BT-M6Z02-RF
Note: if product is in RF link mode and you press it 5 seconds again, product is reset: the RF link is removed.
C. DIP switch configuration
When you unscrew the front face of BT-HCM02-RF, on the right of the product, you have access to 4 switches
used for advanced configuration:
By default position is OFF for the 4 switches
Switch 1: Heat / Cool (HC) signal source (refer to section 7)
ON: BT-M6Z02-RF gets HC information from the BT-CT02-RF
OFF : BT-M6Z02-RF gets HC information from the inputs (Water sensor OR Input free contact)
Switch 2: Humidity function
ON: Function is OFF (dehumidifier output not active)
OFF: Function is ON: when a humidity default is detected in the system dehumidifier output is ON
Switch 3: Time before switching Heat / Cool (HC) mode
ON: HC Switch is effective 2 seconds after the change has been detected
OFF: HC Switch is effective 5 minutes after the change has been detected
Switch 4: Type of control on the heating and cooling outputs
ON: Heating or cooling outputs follow the heating or cooling demand of the installation (Ex: In heating
mode, if any zones are in heating demand, the heating is switched ON)
OFF: Heating or cooling outputs follow the working mode of the installation (Ex: In heating mode, the
heating output is always ON)
(1) (2)
(3)
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Watts BT-HCM02 - Heat and cool module at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Watts BT-HCM02 - Heat and cool module in the language / languages: English, German, Dutch, French, Italian as an attachment in your email.

The manual is 1.91 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info