1. USER GUIDE
Heat & cool module BT-HCM02-RF is specially designed to control your Under Floor Heating & Cooling system.
It is linked to your installation in RF (868MHz) via the BT-M6Z02 RF.
BT-HCM02-RF can get Heat/Cool signal from different sources:
- input free contact from Heat Pump output
- input free contact for a manual switch
- a NTC sensor to measure the water temperature inlet
- from the BT-CT02-RF (BT-HCM02-RF configured in slave mode)
BT-HCM02-RF has also some outputs for:
- global pump of the system
- Dehumidifier outputs in case of humidity default detected (in association with BT-D(P)02-RF RH thermostats)
- Heat and Cool outputs to switch installation in Heating / Cooling
2. TECHNICAL CHARACTERISTICS
BT-HCM02 RF
Operating Temperature
0°C to 50°C
Supply Voltage
230VAC +- 10% 50Hz
Outputs:
Heating and cooling
Humidity drier
Pump
2 x Relay => 5A / 250VAC (Free contact)
1 x Relay => 5A / 250VAC (Free contact)
1 x Relay => 5A / 230 VAC ( L, N)
Input:
HC
HC input could be connected to
a free contact for a manual switch or Heat Pump output
a CTN 10K to measure the water temperature
Radio Frequency
868,3 MHz <10mW.
Range of approximately 180 meters in open space.
Range of approximately 50 meters in residential environment.
CE Directives
Your product has been designed in
conformity with the European
Directives.
R&TTE 1999/5/EC
LVD 2006/95/EC
EMC 2004/108/EC
RoHS 2011/65/EU
Protection
IP 30
Combination
Only with BT-M6Z02-RF
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Watts BT-HCM02 - Heat and cool module at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Watts BT-HCM02 - Heat and cool module in the language / languages: English, German, Dutch, French, Italian as an attachment in your email.

The manual is 1.91 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info