compressor PCPS 10-1100
Errors and faults
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
Troubleshooting tasks which require the housing to be opened
must only be carried out by an authorized specialist electrical
company or by Trotec.
Light smoke or odour is emitted during the first use:
This is not a fault. These phenomena disappear after a
brief runtime.
The device does not start:
Check the power connection.
Check the power cable and mains plug for damages. If you
notice damages, do not try to take the device back into
operation. To avoid safety hazards, do not perform any
repairs. Send the device to a specialist electrical company
or to Trotec to have the power cable and mains plug
replaced.
Check the on-site fusing.
Check the outside temperature. At temperatures
below+5°C, the motor becomes sluggish and can be
difficult or impossible to start up. Do not use the device at
an temperatures below+5°C.
The device is running but there is no apparent inflation/
The pressure gauge shows no pressure:
Check the valve adapter used for proper fit. Air might be
escaping at the valve of the item to be inflated.
Let the device run for a moment. The pressure will only be
shown on the pressure gauge after the pressure inside the
item to be inflated has exceeded the ambient pressure.
Check the item to be inflated for leaks.
Check the compressed-air gun for proper functioning, and
replace it if necessary.
The device is running but there is no pressure build-up:
The check valve is leaky. Have the check valve inspected
and, if necessary, replaced by a specialist workshop.
Check the seals. Have broken seals replaced by a
specialist workshop.
The device is running but the connected accessories do not
work:
Check the accessories for proper functioning. Replace
defective accessories.
Check the compressed-air hose and the quick coupling,
and have them replaced by a specialist workshop if
necessary.
The device becomes hot:
Note
The device is not suitable for continuous operation.
Over a period of 10minutes, do not use the device for
more than 1.5minutes in continuous operation. Allow
the device to cool down for the remaining time.
Should the device be overheating nonetheless, switch
the device off and disconnect it from the mains.
Allow the device to cool down sufficiently before
switching it back on.
Check whether the device is suitable for the tasks to be
carried out.
Keep the venting slots or air inlet and outlet clear to
prevent the motor from overheating.
Note
Wait for at least 10minutes after maintenance and
repair work. Only then switch the device back on.
Your device still does not operate correctly after these
checks?
Please contact the customer service. If necessary, bring the
device to an authorized specialist electrical company or to
Trotec for repair.
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Trotec PCPS 10-1100 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Trotec PCPS 10-1100 in the language / languages: English as an attachment in your email.

The manual is 0,49 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Trotec PCPS 10-1100

Trotec PCPS 10-1100 User Manual - German - 17 pages

Trotec PCPS 10-1100 User Manual - Dutch - 16 pages

Trotec PCPS 10-1100 User Manual - French - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info