Troubleshooting
SensorLight without power
SensorLight will not switch ON
SensorLight will not switch OFF
SensorLight switches ON when it
should not
Change in SensorLight reach
LED ON all the time although
manual override is not selected
Malfunction
Functional Warranty
This STEINEL product has been manufactured with
utmost care, tested for proper operation and safety
and then subjected to random sample inspection.
STEINEL guarantees that it is in perfect condition and
proper working order.
The warranty period is 36 months, starting on the date
of sale to the consumer. We will remedy defects caus-
ed by material flaws or manufacturing faults. The
guarantee will be met by repair or replacement of de-
fective parts at our own discretion. The warranty shall
not cover damage to wear parts, damage or defects
caused by improper treatment or maintenance.
Further consequential damage to other objects shall
be excluded.
Claims under the warranty will only be accepted if the
unit is sent fully assembled and well packed with a
brief description of the fault, a receipt or invoice (date
of purchase and dealer's stamp) to the appropriate
Service Centre.
Repair Service:
Please ask your nearest service
centre how to proceed for repairing
faults not covered by the warranty or
occurring after the warranty expires.
- 11 -
Fuse faulty, not switched ON,
break in wiring
Short circuit
Fit new fuse; switch ON mains
switch; check wiring with volt-
age tester
Check connections
Twilight setting in night-time
mode during daytime operation
Power switch OFF
Fuse faulty
Detection zone not properly
targeted
Internal electrical fuse has been
activated (LED ON all the time)
Reset (button )
Switch ON
New fuse, check connection
if necessary
Re-adjust
Switch SensorLight OFF and
back ON again after 5 sec.
Continued movement within the
detection zone
Basic lighting level > 0 %
Check detection zone and
re-adjust if necessary
Set basic lighting level to0 %
(button )
Wind is moving trees and
bushes in the detection zone
Cars in the street are being
detected
Sunlight shining on the lens
Sudden temperature changes
due to weather (wind, rain,
snow) or air expelled from fans,
open windows
Lens not pressed firmly enough
into groove
Change detection zone
Change detection zone
Mount sensor in a sheltered
place or change detection zone
Change detection zone, change
site of installation
Press lens into groove
Differing ambient temperatures Use shrouds to define detection
zone precisely
Internal fuse activated Switch SensorLight OFF and
back ON again after 5 sec.
LEDs flickering
Local power grid see note on page 9
Cause Remedy
Manual override function
If a mains switch is installed in the mains supply lead,
the SensorLight provides the following functions in
addition to just being able to switch it ON and OFF:
Sensor operation
1) Switch light ON:
Turn switch OFF and ON once.
Light stays ON for the period selected.
2) Switch light OFF:
Turn switch OFF and ON once.
The light goes out or switches over to sensor mode.
Manual override
1) Activate manual override:
Turn switch OFF and ON twice. The light is set to
stay ON for 4 hours (red LED lights up). Then it
returns automatically to sensor mode (red LED OFF).
2) Deactivate manual override:
Turn switch OFF and ON once. The light goes out or
switches over to sensor mode.
Important:
The switch should be actuated in rapid succession
(in the 0.5 – 1 sec. range).
Reset function
The light can be returned to its original settings at any
time (daylight operation 2000 lux, ON time 5 seconds
and basic lighting level OFF).
To do this, hold all three buttons down at the same
time until the LED comes ON and goes out again
(approx. 5 sec.).
Soft light start
The SensorLight features a soft light start function.
This means that when the light is switched ON, it
does not go directly to maximum output but gradually
increases brightness to 100% over the space of one
second. Brightness is also gradually reduced when
the light is switched OFF.
Basic reach setting
The sensor lens is divided into two detection zones.
One half provides a max. reach of 5 m, the other half
a max. reach of 12 m (when installed at a height of
approx. 2 m). After fitting the lens (firmly clip lens into
the groove provided), a small arrow marks the max.
reach of 12 m or 5 m selected (arrow left = 5 metres,
arrow right = 12 metres).
Using a screwdriver, the lens can be unclipped from
the groove at the side and re-positioned for the reach
you require.
Declaration of conformity
This product complies with
- Low Voltage Directive 2006/95/EC
- EMC Directive 2004/108/EC
- RoHS Directive 2011/65/EC
- 10 -
Set dimming level of your choice:
- Hold button down until LED flashes.
- Keep button pressed, the system will slowly run
through dimmer range from 0 – 50%.
- Release button when chosen setting is reached.
The LED will now continue flashing for about 5 sec.
This period may be used for optimising the dimmer
setting.
Precision adjustment
using shrouds
Shrouds may be used to define the detection zone
exactly as you require in order, for example, to blank
out or specifically target paths or neighbouring prem-
ises. The shrouds can be divided or cut with a pair of
scissors along the vertical and horizontal grooves.
They can be clipped into the top channel around the
centre of the lens. They are held securely in place by
fitting the cover .
(Fig. shows examples of how you can reduce the
angle of coverage and shorten reach.)
Operation / Maintenance
The SensorLight is suitable for switching ON light
automatically. Weather conditions may affect the way
the SensorLight functions. Strong gusts of wind,
snow, rain or hail may cause the light to come ON
when it is not wanted because the sensor is unable to
distinguish sudden changes of temperature from
sources of heat. The detector lens may be cleaned
with a damp cloth if it gets dirty (do not use cleaning
agents).
Caution:
Stainless steel should be cleaned at regular intervals
(about every 3 months) with a standard stainless steel
cleaner. If it is not cleaned, corrosion may occur on the
surface (flash rust).
GB
6


Need help? Post your question in this forum.

Forumrules
1

Forum

steinel-l-610-led

Reset search

  • I'm setting up my Steinel L 610 LED and I don't quite understand the section for setting the 'ON' time.
    First bit was fine 'Hold button until LED flashes' but when I released it didn't stop flashing for a while and didn't flash again so I don't know the 'ON' time. I also don't understand the next bit about pressing the button a second time until the LED goes out. Is this when the LED is flashing the second time and do you hold the button for the required time you want after the light has gone out or what? Submitted on 15-3-2021 at 20:18

    Reply Report abuse
  • My L610LED sensor light is permanently on in a lower light setting, but light level increases to full when motion is detected.
    How can I reset it to normal operation? Submitted on 25-1-2021 at 21:26

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Steinel L 610 LED at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Steinel L 610 LED in the language / languages: All languages as an attachment in your email.

The manual is 1,14 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info