- For continue protection against fire, replace fuse only with the
specified voltage and current ratings: F 250mA/600V,
F 10A/600V(quick acting)
- Do not use abrasives or solvents on the meter, use a damp cloth
and mild detergent only.
- Always set the power switch to the OFF position when the meter
is not use.
- If the meter is to be stored for a long period of time, the batteries
should be removed to prevent damage to the unit.

- This meter is a portable professional measuring instrument with
handsome LCD easilyreading.
- Single operation of a transform switch makes measurement con
venient. Overload protection and low battery indication are
provided, this meter is ideal for use in the fields, workshop, school,
hobby and home applications.
- This meter is with the fuctions of ‘data hold’.

1. LCD display
2. ‘Hold’ key
3. Rotary switch
4. Terminals

- Environment conditions:
600V CAT.III
Pollution degree: 2. Altitude < 2000 m.
- Operating temperature:
0~40
°C
(32
°F
- 104
°F),
(<80% RH,non-condensing)
- Storage temperature:
-10~50 OC(14
°F
- 122
°F
), (<70% RV, battery removed)
- Temperature Coefficient:
0,1×(specified accuracy) / OC (<18
°C
of >28
°C
)
- MAX. Voltage between terminals and earth ground:
600V AC rms of 600V DC
- Fuse Protection: mA: F 250mA/600V ø 6.3×30,
A: F 10A/600V ø 6.3×30.
- Display: LCD, 1999counts, updates 2-3/sec.
- Over Range indication: LCD will display “1”.
- Low battery indication:
The “ “ is displayed on the LCD.
- Polarity indication: “ “ displayed automatically.
- Power source: 9V
- Battery type: 6F22 9V
- Dimensions: 158(L)×74(W)×37(H) mm.
- Weight: 220 g. Approx. (battery included).

Accuracy: ±(% reading + number of digits) at 18°C - 28°C
(64°F - 82°F) with relative humidity to 80%.
(Accuracy is specified for a period one year after calibration).

Range Resolution Accuracy
0.2V 0.1mV
2V 1mV
±0.5%±1
20V 0.01V
200V 0.1V
600V 1V ±0.8%±2
- Input impedance: 10MΩ
- Max. input voltage: 200mV range: 250VDC or AC rms
2V - 600V ranges: 600VDC or AC rms.

Rance Resolution Accuracy
2V 1mV
±0.8%±3
20V 10mV
200V 0.01V
600V 1V ±1.2%±3
Input impedance:10MΩ
Max. iinput: 200mV range: 250VDC or AC rms
2V - 600V ranges: 600VDC or AC rms
Frequency range: 40Hz-1000Hz
Response: Average, calibrated in rms of sine wave.
Skandia Digital Multimete 1088025


Warning
To ensure safe operation and in order to exploit to the full the
functionality of the meter, please follow the directions in this
section carefully.
This multimeter has been designed according to IEC-61010
concerning electronic measuring instruments with an overvoltage
category CAT III 600V and pollution 2. Only to use for measurements
in a 1-phase elektrical 600V installation after the group distribution
frame.! Also to use for measurements of electric appliances with a
plug and lighting connected on this installation after the group
distribution frame.! Suitable for measurements of dc voltage and
AC voltage till maximum 600V.
Follow all safety and operating instructions to ensure that the meter
is used safely and is kept in good operating condition.
With proper use and care, the digital meter will give you years
of satisfactory service.

- When using the meter, the user must observe all normal safety
rules concerning:
Protection against the dangers of electrical current.
Protection of the meter against misuse.
- When the meter is delivered, check that it has not been
damaged in transit.
- When poor condition under harsh preservation or shipping
conditions caused, inspect and confirm this meter without
delay.
- Test leads must be in good condition. Before using verify
that the insulation on test leads is not dameged and/or the
leads wire is not exposed.
- Full compliance with safety standards can be guaranteed
only if used with test leads supplied. If necessary they must
be replaced with the same model or same electric ratings.

- Before using, you must select the right input jack, function and
range.
- Never exceed the protection limit values indicated in specifications
for each range of measurement.
- When the value scale to be measured is unknown beforehand, set
the range selector at the highest position.
- Do not measure voltage if the voltage on the termanals exeeds
600V above earth ground.
- Always be careful when working with voltages above 60V DC
or 30V AC rms, keep fingers behind the probe barriers while
measuring.
- Before rotating the transform switch to change functions and
ranges, disconnect test leads from the circuit under test.
- Never perform resistance, temperature, transistor, diode and
continuity measurements on live circuits.
- Never use the meter under the condition of the explosive air,
stream or dirt.
- If any faults or abnormalities are observed, the meter can
not be used any more and it has to be checked out.
- Never use the meter unless the rear case is in place and
fastened fully.
- Please do not store or use meter in areas exposed to direct
sunlight, high temperature, humidity or condensation.

Caution: refer to the instruction manual. Incorrect
use may result in damage tothe device or its
components.
Earth
This instrument has double insulation.
Fuse: F 250mA/600V, F 10A/600V.

- please do not attempt to adjust or repair the meter by removing
the rear case while voltage is being applied. A technician who fully
understands danger involved should only carry out such actions.
- Before opening the battery cover or case of the meter, always
disconnect test leads from all tested circuits.
- To avoid the wrong reading causingelectricity attack, when the
meter displays “ ”, you must change the battery.


Rance Resolution Accuracy
200uA 0.1uA
2mA 1uA
±0.8%±1
20mA 10uA
200mA 100uA ±1.2%±1
10A 10mA ±2.0%±5
Overload protection: F 250mA/600V, F 10A/600V fuse.
Max. input current: mA: 250mA, 10A Jack: 10A

Rance Resolution Accuracy
2mA 1uA
±1,2%±3
20mA 10uA
200mA 0.1mA ±2,0%±3
10A 10mA ±3,0%±7
Overload protection: F 250 mA/600V, F 10A/600V fuse.
Max. input current: mA: 250mA dc or 250mA ac rms
10A: 10A continuous, 10A 15 sec. Max.
Frequency Range: 40Hz-1kHz
Indication: Average (rms of sine wave)

Rance Resolution Accuracy
200Ω 0.1Ω ±0,8%±3
2KΩ 1Ω
20KΩ 10Ω ±0,8%±1
200KΩ 100Ω
2MΩ 1kΩ
20MΩ 10kΩ ±1,0%±2
Overload protection: 250 DC or 250 AC rms.

Display: read approximate forward voltage of diode
Forward DC Current: approx. 1mA
Reversed CD Voltage: approx. ca. 2,8V
Overload protection: 250V DC or 250V AC rms

Built-in buzzer sounds if resistance is less than approx. 50Ω.
Open circuit voltage: approx. 2,8V
Overload protection: 250V DC or 250V AC rms.

Rance Accuracy Discharge current
1,5V
±0,8%±1
100mA
9V 6mA
Overload protection: 1.5V: F 250mA/600V fuse
9V: 250V dc or 250V ac rms.


- Set rotary switch to the desired V
or V~ range.
- Connect the black and red test leads to the COM and V terminals
respectively.
- Connect the test leads to the circuit being measured.
- Read the displayed value. The polarity of red test lead connection
will be indicated when making a DCV measurement.
- When only the figure “1” is displayed, it indicates overrange
situation and the higher range has to be selected
To avoid electrical shock and/or damage to the instrument, do
not attempt to take any voltage measurement that might exceeds
600V dc or ac rms. Do not apply more than 600V dec or ac rms
between the common terminal and the earth ground.

- Set the rotary switch to the desired A
or A~ range.
- Connect the black test lead to the COM terminal and the red
test leads to the mA terminal for a maximum of 250,A. For a
maximum of 10A, move the red test lead to the 10A terminal.
- Connect test leads in series with the load in which the current is
to be measured.
- Read the displayed value. The polarity of red test lead connection
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Skandia 1088025 - Digitale Multimeter at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Skandia 1088025 - Digitale Multimeter in the language / languages: English, Dutch as an attachment in your email.

The manual is 1,4 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info