759907
7
Zoom out
Zoom in
Previous page
1/8
Next page
- 7 - 09/2020 Copyright © 2020, Fast ČR, a.s.
If the temperature in the room is in the range from 26°Cto 28°C, the fan will automatically switch between speeds 4 – 5 – 6 in 15-second
intervals.
If the temperature in the room is ≤ 25°C, the fan will automatically switch between speeds 1 – 2 – 3 in 15-second intervals.
Operating mode "Normal" – in this mode, the fan speed is set according to personal preferences.
Note:
To prevent the speeds from changing too quickly, in the "Smart" mode a15-second interval is set for each speed.
Setting the automatic shut-off timer:
Button serves to set the automatic shut-off timer. Press button and "0" will appear on the display and the indicator light above
the button will be lit. Repeatedly press button to set the time (0 hours to 8 hours), after which the fan will shut off automatically.
Setting oscillation
The fan enables vertical and horizontal oscillation to be set concurrently.
1. Vertical oscillation
Vertical oscillation can be set to an angle of 30°, 60° or 90°. To set the vertical oscillation, press button and the indicator light at the
"30°" position will be lit. If you wish to select avertical oscillation of "60°" or "90°", then repeatedly press button until the indicator
light is lit at the position of your desired angle. The fan will start to automatically move up and down.
If you wish to turn off the vertical oscillation function, repeatedly press button until no indicator light is lit. The fan will remain at
the angle at which it was turned off.
2. Horizontal oscillation
Horizontal oscillation can be set to an angle of 30°, 60° or 90°. To set the horizontal oscillation, press button and the indicator light
at the "30°" position will be lit. If you wish to select ahorizontal oscillation of "60°" or "90°", then repeatedly press button until the
indicator light is lit at the position of your desired angle. The fan will start automatically turning left and right.
If you wish to turn off the horizontal oscillation function, repeatedly press button until no indicator light is lit. The fan will remain at
the angle at which it was turned off.
Note:
If you need to set the fan to acertain position, use the vertical or horizontal oscillation button (not both) and when the fan is in
the desired position, repeatedly press the vertical or horizontal oscillation button until no indicator light is lit. This will stop the
vertical or horizontal oscillation, and the fan will be set in the desired position.
Temperature display
The fan has asensor that senses the ambient temperature. Temperature details are shown on display B1 in the fan'sstand-by mode.
Power-saving mode
The fan has apower-saving mode, which dims the display approximately 15 seconds after the last setting was made. Press any button to
light up the display again.
REMOTE CONTROL
Inserting and replacing batteries in the remote control
Slide out the battery compartment from the underside side of the remote control and insert aCR2032 type 3V battery into it. When inserting
the battery, heed the correct polarity.
If the battery in the remote control is flat, replace it with anew battery of the same type.
If you decide not to use the remote control for an extended period of time, we recommend removing the battery. If the battery were to
leak into the inner area of the remote control, this could result in its damage.
Note:
Never put batteries in afire, short circuit them or damage them in any way. Dispose of them ecologically at the end of their
lifetime. Never throw batteries out with communal waste.
The function of the buttons on the remote control and the control panel A4 are the same. If you wish to use the remote control, point it
at the control panel A4.
Note:
If there are obstacles located between the remote control and the control panel A4, the signal may not be transmitted.
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sencor SFN 2540 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sencor SFN 2540 in the language / languages: English as an attachment in your email.

The manual is 1,08 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page