757420
12
Zoom out
Zoom in
Previous page
1/12
Next page
100-0005
東京都千代田区丸の内3-1-1国際ビ
550-0013
大阪市西区新町1-4-24大阪四ツ橋新町ビルディング
https://www.seikowatches.com/
お客様相談室
通話料無料
0120-612-911
BSB8B54 H2-3.indd 2-3 18.2.15 0:57:11 PM




When all the hands stop pointing to 12 o’clock
0 minutes and 0 seconds, push the crown back.
3
  



2
Continued on the next page.





Pushthe
crownback.





Keep pressing down the Button A and B at the
same time for 4 seconds, and then release them.

1

Pullout
thecrown
tothe
secondclick.
In case of an abnormal movement
How to reset the built-in IC (from ① to ③ )
In the case that the watch moves
abnormally or that the watch does
not move at one-second intervals
even after fully charging the
battery, perform the procedures
from to to re-establish
normal function.
 


Pull out the crown to the second
click.





BSB8B54 p095-188 欧文.indd 182-183 19.11.6 11:31:45 AM
185
Keep pressing down the Button A (for 3 seconds) until the
second hand stops pointing to the 55-second position.
6
■ Setting the day of the week to “M” (Monday.) ( ⑥,⑦ )

Thewatchentersthepreliminaryposition
settingmodefordayoftheweek.
ButtonAfor
3seconds
Troubleshooting
7
Press the Button B to set
the day hand to point to M.”
7
Makesurethatthedayhandissetto
pointto“M.”
ButtonB
Toadvance
rapidly
Keeppressingdownthebuttonforlongerthan2seconds.
Pressthebuttononceagaintostop.
Tone-tune
Keeppressingdownthebuttonaslongasyouwanttoadvancethedayhand.
Continued on the next page.
184184
Within 20 seconds, press the
Button B to set the date to “ 1.”
5
Keep pressing down the Button A and B (for 4 seconds) at the same
time until the second hand stops pointing to the 13-second position.
4
※Donotpull
thecrown
out.
■ Setting the date to the “1st.” ( ④,⑤ )
※
First,presstheButtonB,andsubsequentlypresstheButton A while
keepholdingdowntheButtonBsoastopressbothofthemsuccessfully.
ButtonB

Makesurethatthenumericalnumber“1”
islocatedatthecenterofthedatewindow.
※
If1”isalreadydisplayedinthedatewindow,moveontotheprocedure⑥.
Within 20 seconds after procedure ④ is completed, start the operation of procedure ⑤ .
※Ifthewatchisleftuntouchedfor20secondsafterthesecondhandstops,thewatchautomatically
returnstotheTIMEdisplaymode.Ifthishappens,restarttheoperationfromprocedure④.
※
PresstheButton
B withyour
fingerorwith
anobjectwith a
longtaperedtip
onP.10 6 .
ButtonA
ButtonB
Presssimultaneously
for4seconds
Toadvance
rapidly
Keeppressingdownthebuttonforlongerthan2seconds.
Pressthebuttononceagaintostop.
Tone-tune
Keeppressingdownthebuttonaslongas
youwanttoadvancethenumericalnumber.
Troubleshooting
7
Thewatchentersthepreliminarypositionsettingmodefordate.
BSB8B54 p095-188 欧文.indd 184-185 19.11.6 11:31:45 AM
187
11
Set the Time by receiving
radio signals
■ Setting the time
How to conduct manual
reception → P.156
Whenthewatchisunabletoreceive
radiosignals,youcanmanuallyset
thetime,dateanddayoftheweek.
Howtomanuallysetthetime→P.160
Howtomanuallysetthedate→P.162
Howtomanuallysetthedayoftheweek→P.165
Aftercompletingtheproceduresup
to⑩,makesuretosetthetime.
The operation is completed when the
time, date and day of the week are set.
Troubleshooting
7
Set the Daylight Saving
Time (DST) as necessary.
TosettheDaylightSavingTime,selectthetimezone
indexnexttothetargettimezone(+1hour)whichis
indicatedbythearrowunderthetimezoneindex.
<Example>WhentheDaylightSavingTimeisbeing
observedinParis,setthesecondhandtopointatthe
nexttimezoneindexCAI,asindicatedbythearrow.
TimezoneindexforPAR(Paris)
TimezoneindexforPAR(Paris)
whiletheDaylightSavingTime
isbeingobservedinParis.
10
186
Troubleshooting
7
ButtonBfor
4seconds
Within 10 seconds after procedure ⑧ is completed, start the operation of procedure ⑨ .
※
Ifthewatchisleftuntouchedfor10secondsafterthesecondhandstops,thewatchautomatically
returnstotheTIMEdisplaymode.Ifthishappens,restarttheoperationfromprocedure⑧.
9
Witheachpressingofthebutton,thesecondhandmoves
totheadjacenttimezoneindex.
Within 10 seconds after procedure 8 is
completed, press the Button A or B to set the
second hand to point to the target time zone.
ButtonA
forclockwise
turn
ButtonBfor
counterclockwise
turn
Press the Button B (for 4 seconds)
until the second hand stops.
8

Thesecondhandwillstarttomove
andstoppointingtothecurrently
selectedtimezone(UTC/LON).
■ Setting the time zone ( ⑧ to ⑩ )
10 seconds after procedure is completed, the watch
automatically exits the Time Zone Setting mode.
20 seconds after procedure ⑦ is completed, the watch automatically
exits the preliminary position setting mode for day of the week.
BSB8B54 p095-188 欧文.indd 186-187 19.11.6 11:31:46 AM
188
Specications
8
1. Basic feature ・・・・・・・・・
2.
Frequency of crystal oscillator
・・
3.
Loss/gain (monthly rate)
・・・
4.
Operational temperature range
・・
5. Driving systems ・・・・・
6. Power source ・・・・・・・・
7.
Duration of operation
・・
8.
Time setting by receiving the JJY-LF radio signal
・・
9.
IC (Integrated Circuit)
・・
Specications
Thespecicationsaresubjecttochangewithoutpriornoticeforproductimprovement.
Basic watch with three hands (hour, minute and second hands), date display,
Retrograde day indicator, Sub dial with 2 hands (Hour and Minute hands)
32,768 Hz (Hz = Hertz ... Cycles per second)
Loss / gain ± 15 seconds on a monthly rate (Except the case when the watch is
used without an automatic time setting by receiving a radio signal and when it is
worn on the wrist within a normal temperature range between 5℃ and 35℃ ).
Between −10℃ and +60℃
Step motor (Hour and minute hands, second hand, and the date, day and
hour and minute hands for sub dial)
Secondary battery, 1 piece
Approximately nine months (Fully charged, and the Power Save is not activated).
If the Power Save is activated after it is fully charged, the watch
continues to run for approximately two years at maximum.
Automatic reception (at 2:00 AM, 3:00 AM and 4:00AM)
Reception attempts depend on the radio signal receiving conditions.
After having received a radio signal, the watch will start to move
depending on the quartz movement until the next reception.
Manual reception is also available.
Oscillator, frequency divider and driving circuit C-MOS-IC, 3 pieces
BSB8B54 p095-188 欧文.indd 188 19.11.6 11:31:46 AM
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Seiko 8B54 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Seiko 8B54 in the language / languages: English as an attachment in your email.

The manual is 8,91 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info