V5075-561-00 09/08
Resetting to factory settings (Reset)
Under certain circumstances, it is necessary to reset this
device (and possibly the other devices in the radio sys-
tem) to its factory settings and to reconfigure the radio
system:
½
CAUTION
When you reset to the factory settings, all the set-
tings and connections for this CONNECT device
are lost. The radio system may no longer work
and will need to be reconfigured: see the sepa-
rate description of the CONNECT radio system
(supplied with devices with system administra-
tion).
1 Using an insulated tool such as an insulated phase
tester, tap switch button B three times in quick suc-
cession (within approx 1.5 seconds).
LED A flashes at one-second intervals.
2 Then press and hold the switch button until the LED
stops flashing (approx. 5 seconds).
The device has now been reset to its factory settings.
Notes for experienced users who want to use this device
with Z-wave compatible devices from other manufactur-
ers:
Technical data
Connected loads: AC 230 V, 10 A; cos ϕ = 0.6
Allowed loads: 2000 W (incandescent lamps
230 V)
1500 W (halogen lamps 230 V)
35 µF (capacitive load in lumi-
naires with electronic transform-
er)
Type of protection: IP 20
Radio frequency: 868 MHz
Radio protocol: Z-wave
CONNECT device
type: Receiver
Range: up to approx. 100 m outdoors
up to approx. 30 m in buildings
(depending on building materi-
als)
Dimensions
(H x W x D):
approx. 48 x 52 x 27 mm, without
connecting cables
Z-wave device type Routing slave
Learn -Mode:
(for integration into Z-
wave systems of other
manufacturers)
Triple click on the switch button
Send “Node info
frame”
Triple click on the switch button.
List of functions Parameter number
Staircase timer 176, 177
Additional limit duration
(after brief interruption)
183
|
This device can be used with al devices that are
compatible with Z-Wave; this also applies to de-
vices from other manufacturers. Each Z-Wave-
compatible device can be added to a Z-Wave sys-
tem, in which case it then also functions as a rout-
er providing command forwarding is supported.
Configuration of a Z-Wave system is described in
the description of devices with system adminis-
tration (e.g. CONNECT radio push-button).
Some functions are only possible with devices
that are compatible with the CONNECT radio sys-
tem.
If you have technical questions, please contact the Cus-
tomer Care Center in your country.
www.schneider-electric.com
This product must be installed, connected and used in
compliance with prevailing standards and/or installation
regulations. As standards, specifications and designs
develop from time to time, always ask for confirmation of
the information given in this publication.
Z-wave designation CONNECT designation
Inclusion Teach (sends Node info frame),
see CONNECT radio system
description
Exclusion Reset to factory settings; com-
plete programming
Primary Device with system administra-
tion
Schneider Electric Industries SAS
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Schneider Electric MTN507501 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Schneider Electric MTN507501 in the language / languages: English as an attachment in your email.

The manual is 0,13 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Schneider Electric MTN507501

Schneider Electric MTN507501 User Manual - German, Dutch, French, Italian - 4 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info