THE INFORMATION DISPLAY
The information display not only serves as an indicator of the (set) time and
temperature (sections C, E, and F), it also indicates any malfunctioning of the
heater. The code on the information display tells you what is the matter:
Code Information Action
Time
----
The heater has been automa-
tically turned off by a power
cut or bad connection.
Restore power or restore the
connection. Press the ON /
OFF key
21
again.
E01
An earthquake (magnitude 5
or more), strong vibrations or
a shock will ensure that the
heater automatically
turns off. (The safety system
against shocks has worked).
Make sure there are no com-
bustible materials around the
heater, or fuel leakages. Press
the ON / OFF key
21
again.
E02
E03
The heater has been automa-
tically turned off after a fault
or during ignition or due to
the presence of water or dust
in the fuel filter or in the
fixed tank.
Remove the water and the
dust in the fixed tank. Clean
the fuel filter (see chapter M).
Press the ON / OFF button
21
again.
E07
An increase in ambient
temperature has turned the
heater off. (The tempera-
ture monitoring system has
worked).
Ventilate the space. Let the
heater cool off. Press the ON /
OFF button
21
again.
Filter
E09
Filter
The heater has been automa-
tically turned off because the
hot air stream, the ventila-
tor or the ventilator filter
is blocked or hindered by
something. (The safety system
against overheating has
worked).
Remove obstacles from the
ventilator opening. Clean the
ventilator filter (see chapter
M) Press the ON/OFF but-
ton
21
again. If the problem
occurs again after taking the
above measures, contact your
dealer.
E13
The heater has been turned
off in a closed space. (The
safety system against incom-
plete combustion has wor-
ked).
Ventilate the space and press
the ON / OFF button
21
again.
Ensure the space is sufficien-
tly ventilated.
E17
The heater has been turned
off due to an increased CO2
concentration. (The system
for air quality monitoring has
worked).
Ventilate the space and set
the ON / OFF button
21
again.
Ensure the space is sufficien-
tly ventilated.
The ON indica-
tor flashes. Err
lights up
The heater has automatically
stopped because the ON / OFF
button was kept pressed in or
was blocked.
Remove obstacles from the
ventilator opening. Clean the
ventilator filter (see chapter
M) Press the ON/OFF but-
ton
21
again. If the problem
occurs again after taking the
above measures, contact your
dealer.
F00 – F30
Poor functioning. Heater
needs maintenance
Note the messages displayed
and turn the heater off. Con-
tact your dealer.
71
71


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Qlima - Zibro SRE5035C at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Qlima - Zibro SRE5035C in the language / languages: All languages as an attachment in your email.

The manual is 6,75 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Qlima - Zibro SRE5035C

Qlima - Zibro SRE5035C User Manual - Dutch - 18 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info