Copyright © 2014 VARO P a g e | 5 www.varo.com
Air-operated tools must be inspected periodically, and worn or broken parts must be
replaced to keep the tool operating safely and efficiently. Check and change all worn or
damaged O-ring, Seals, etc. Tight all the screws and caps in case personal injury.
Make regular inspection for free movement of trigger, Spring and safety mechanism to
assure safe system is complete and functional: no loose and missing parts, no building
or stocking parts.
Keep magazine and nose of tool clean and free of any dirt lint or abrasive particles.
When temperatures are below freezing, tools should be kept warm by any convenient,
safe method.
9 TECHNICAL DATA
Model
POWAIR0806
Activation mode
Single sequential action
Max. allowable pressure
120PSI(8.3 bar)
Operating pressure
60-100PSI(4-7bar)
Air inlet size
¼”
Avg. air consumption
65l/min(2.29cfm)
Recommended lubricant
White mineral oil
Nail capacity
100pcs
10 NOISE
Noise emission values measured according to relevant standard. (K=2.5)
Acoustic pressure level LpA
89 dB(A)
Acoustic power level LwA
102 dB(A)
ATTENTION! Wear hearing protection when sound pressure is over 85
dB(A).
aw (Vibration) :
1.9 m/s²
K= 0.5 m/s²
11 TROUBLESHOOTING
SYMPTOM
SOLUTIONS
Air leak
near top of tool or in
trigger area
Check and replace O-ring.
Check and replace.
Check and replace trigger
valve stem, seal or O-ring
Air leak near bottom of
tool.
Tighten screws.
Check and replace O-rings
or bumper.
Air leak between body
Tighten screw.
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Powerplus POWAIR0806 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Powerplus POWAIR0806 in the language / languages: English as an attachment in your email.

The manual is 0,25 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Powerplus POWAIR0806

Powerplus POWAIR0806 User Manual - German - 8 pages

Powerplus POWAIR0806 User Manual - Dutch - 8 pages

Powerplus POWAIR0806 User Manual - French - 8 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info