TECHNICAL DATA
ATTENTION: Dangerous voltage!.
Work with electrical equipment on the 230V mains must be carried out
exclusively by qualified technicians!.
Disconnect the mains voltage before proceeding to the assembly, disassembly
or manipulation of the electrical equipment!.
Power supply
Power consumption
Breaking capacity
230V~ 50Hz
35mA
16A 250V cosφ=1
Radio-frequency
Mounting
Protection degree
Working Temperature
Dimensions
Compatible with
Codified transmission in 868,4MHz with
ERP>8mW and a coverage
of 100m (in the free field)
35mm DIN-rail
IP20
+5ºC ~ +30ºC
1 module wide (17,5mm)
RF-KNX: CH_Room_Regulator_Type_B (0512h)
DE EN
WIRELESS THERMOSTAT SWITCH
TECHNISCHE DATEN
FUNK-THERMOSTAT(-AKTOR)
ACHTUNG: Gefährliche Spannung!.
Arbeiten mit elektrischen Geräten am 230V Netz dürfen nur von qualifiziertem
Fachpersonal durchgeführt werden!.
Trennen Sie die Netzspannung, bevor Sie mit der Montage, Demontage oder
Manipulation der elektrischen Geräte beginnen!.
Stromversorgung
Leistungsaufnahme
Schaltleistung
230V~ 50Hz
35mA
16A 250V cosφ=1
Funkfrequenz
Montage
Schutzart
Betriebstemperatur
Genauigkeit
Kompatibel mit
Verschlüsselte Übertragung,
868,4MHz, ERP > 8 mW,
Reichweite: 100m (auf freiem Feld)
35mm DIN-Schiene
IP20
+5ºC ~ +30ºC
±0,2ºC
RF-KNX: CH_Room_Regulator_Type_B (0512h)
BESCHREIBUNG
Bei diesem Gerät handelt es sich um ein modulares Funk-Thermostat zur Steuerung
von Heizungs-/Klimaanlagen. Hierzu können verschiedene Funk-Sensoren eingebunden
werden: Temperatur-Sensoren, Tür-/Fensterkontakte oder Präsenzmelder.
Es können bestimmte Temperaturwerte festgelegt werden und die Heizungs-bzw.
Klimaanlage gemäß verschiedener Parameter gesteuert werden: Etwa durch einen ext.
Temperatur-Sensor, durch das Öffnen oder Schließen eines Fensters oder Tür mittels
eines Tür-/Fensterkontaktes oder durch die Präsenz von Personen im Raum die mittels
eines Beweguns- oder Präsenzmelders ermittelt wird.
Nach der Inbetriebnahme regelt der Funk-Thermostat die Temperatur auf den
voreingestellten Wert von 25°C. Sollte kein Temperaturwert von einem ext. Fühler
empfangen werden, wird immer auf die voreingestellte Temperatur geregelt.
Das Gerät ist geeignet für die Montage auf der DIN-Schiene in einem Verteilerschrank.
Betriebsart-Wahlschalter:
- B: Verlinkung zum Empfänger trennen.
- P: Einlernvorgang / Programmiermodus (Empfänger oder Sender).
- F: Normalbetrieb.
- A: Normalbetrieb mit zusätzlicher Verstärker-Funktion (Repeater-Funktion).
- R: Löschen aller Verlinkungen (Empfänger und Sender).
Kompatibel mit dem ISO-IEC 14543-2 KNX-Protokoll.
Ein Objekt: CH_Room_Regulator_Type_B 0x512h
INSTALLATION
Installieren Sie den Aktor gemäß des dargestellten Schaltplans.
Die Verwendung der Kontakt-Brücke (E) zwischen Klemme 7 und 8 legt die
Funktionalität des Gerätes fest:
- Mit Brücke: Steuerung einer Klimaanlage.
- Ohne Brücke: Heizungssteuerung.
BETRIEBSMODI
Der Aktor hat zwei Betriebsmodi:
- Heizungssteuerung (offen / ohne Kontaktbrücke E): Sobald der Aktor einen
niedrigeren Temperaturwert von einem ext. Fühler empfängt wird das Relais
geschlossen (Klemme 3 und 4).
- Steuerung einer Klimaanlage (geschlossen / mit Kontaktbrücke E): Sobald der Aktor
einen höheren Temperaturwert von einem ext. Fühler empfängt wird das Relais
geschlossen (Klemme 3 und 4).
Ebenfalls wird das Relais des Thermostates geöffnet oder geschlossen wenn ein
entsprechendes Signal eines Tür-/Fensterkontaktes oder Präsenz-/Bewegungsmelders
empfangen wird.
Im Auslieferungszustand ist der Temperaturwert des Thermostats auf 25 °C eingestellt.
Wird kein anderer Temperaturwert von einem ext. Temperatursensor empfangen, wird
der Wert 25 °C angenommen.
Sie müssen den Thermostat nicht zwingend mit einem externen Temperatursensor
betreiben. Sie haben auch die Option das Signal eines Tür-/Fensterkontaktes oder
Präsenz-/Bewegungsmelders zu verarbeiten. Hierfür belassen Sie die Kontaktbrücke
zwischen Klemme 7 – 8 offen (NICHT GESCHLOSSEN) und stellen am
Temperatur-Wählrad die maximale Temperatur von 30°C ein. Das Relais bleibt solange
geschlossen, bis ein Fenster geöffnet wird oder keine Präsenz/Bewegung im Raum
festgestellt wird.
DESCRIPTION
Wireless modular thermostat that allows controlling the air conditioning system using
wireless sensors: temperature sensor, door/windows contact or presence detector.
It can be fixed a certain temperature and connect or disconnect the heater or the air
conditioning according to different parameters: temperature measured by an external
sensor, the opening or closing of door/window or the presence of people in the room.
By default, after the commissioning is considered an ambient temperature of 25°C. Not
receiving a different value from some associated temperature sensor, it will be
considered at all times that initial temperature is maintained.
DIN-rail mounting. It allows its installation in cabinets, out of the reach of unauthorized
persons.
Working mode selector switch for the setting-up and commissioning:
- B: delete a link from the receiver channel.
- P: link programming of the transmitter or receiver channel.
- F: normal operation.
- A: normal operation with repeater function.
- R: delete all links from the transmitter and receiver channels.
Compatible with ISO-IEC14543-2 KNX protocol.
One object: CH_Room_Regulator_Type_B 0x512h.
INSTALACIÓN
Install the actuator according to the wiring diagram.
Depending on the jumper (E) between terminal 7 and 8, the operation can be:
- With jumper: A.C. control.
- Without jumper: Heating control.
WORKING MODES
This device has two working modes:
- For Heating (without jumper E): at the moment that the received temperature from
any sensor (SE KNX 001) is lower than the value set on the Thermostat, the
thermostat close its relay
(terminals 3 and 4), connecting the device installed at the same.
- For A.C. (with jumper E): at the moment that the received temperature from any
sensor (SE KNX 001) is higher than the value set on the Thermostat, the thermostat
close its relay (terminals 3 and 4), connecting the device installed at the same.
As well, if the Thermostat receives a signal from a linked door/window contact (SE KNX
003) or a motion detector (DM 001 KNX), it will also act opening or closing its relay.
By default, when the thermostat is supplied the stored temperature value is 25°C. As
well, if any other value is received from any temperature sensor, this value is maintained
constantly.
It is possible to use the thermostat only with door/window contacts or presence sensors,
without receiving any external temperature value. In this case, the status of the relay
only depends on the associated sensors. To do this, do not place any bridge between 7
and 8, and set the potentiometer of temperature at maximum (30°C). Thus, the relay will
remain always closed, unless they found an open window or there is no presence in the
room.
Accuracy ±0,2ºC
Abmessungen
1 TE (17,5mm)
C
A
B
D
5
10
15
20
25
30
ºC
R
P
F
A
B
E
N
L
230V~ 50Hz
672 731 rf
1


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Paladin 672 731 rf at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Paladin 672 731 rf in the language / languages: English, German as an attachment in your email.

The manual is 0,27 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info