549543
20
Zoom out
Zoom in
Previous page
1/28
Next page
20
The mesh cap is a consumable part.
Omron recommends to exchange the mesh cap after approximately 1 year.
Remove the mesh cap and install a new one as described on page 11 (section “How to assemble the
unit and fill the medication container”).
Additional instructions for Mesh care
In case the performance of the unit remains reduced even after cleaning and disinfecting, use the
following methods to remove dried medication, lime or saliva which may clog the tiny holes in the mesh
cap.
Leave the mesh cap in a white vinegar solution (1 part vinegar diluted with 3 parts of water) for ½
- 1 hour. In addition, the mesh cap may be kept overnight in a cup of distilled water, in which a tablet
of dental (“false teeth”) cleaner has been added. After cleaning with vinegar or dental cleaner, be sure
to shake off excessive solution, thoroughly but carefully rinse the mesh with distilled water. Shake off
excessive water from the mesh cap and let it air-dry on a clean, lint free (paper) towel.
In case the unit nebulises poorly even after following this procedure, replace the mesh cap.
How to replace the mesh cap
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Omron NE-U22 - MicroAir at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Omron NE-U22 - MicroAir in the language / languages: English as an attachment in your email.

The manual is 3,34 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Omron NE-U22 - MicroAir

Omron NE-U22 - MicroAir User Manual - German - 28 pages

Omron NE-U22 - MicroAir User Manual - Dutch - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info