688907
80
Zoom out
Zoom in
Previous page
1/180
Next page
ENGLISH
EN - 30
4.3.2 - Functional aspects not to be mistaken for anomalies
The following events may occur during normal operation:
a. The compressor does not start up again immediately after a stop (it takes about three minutes
to start again).
- In the operating logic of the appliance a delay between a compressor stop and its successive restart
has been included, so that the compressor itself is protected against activations that are too frequent.
b. Duringtheheatingoperationoftheheatpumpappliances,theowofhotairmayoccursome
minutes after activation of the compressor.
- Shouldthefanstartatthesametimeasthecompressor,fortherstfewminutesitwouldemitcold
air into the room (and this could bother the occupants) since the unit has not yet reached steady
running conditions.
4.3.3 - Console alarms
If one of the following alarms on the display persists for more than three minutes, please contact an Olimpia’s
assistance centre.
ALARM DESCRIPTION
DISPLAY ALARM
CODE
External air temperature probe faulty 1
Condenser temperature probe faulty 2
Inlet temperature probe faulty 3
Compressor current protection 4
Communication error 5
Power line overcurrent 6
Compressor current protection not suitable 7
Power board DC voltage problem 8
Current anomaly 9
Condenser temperature too high 10
UIPM protection 11
EEPROM error 12
Inlet temperature too high 13
Room temperature probe faulty 14
Evaporator temperature probe faulty 15
Evaporator temperature too low 16
Evaporator temperature too high 17
Mains voltage problem 18
Evaporating fan motor failure 19
Water level alarm 20
EEPROM error 21
80

Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Olimpia Splendid Unico Pro Inverter at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Olimpia Splendid Unico Pro Inverter in the language / languages: English, German, French, Italian, Spanish as an attachment in your email.

The manual is 9,64 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Olimpia Splendid Unico Pro Inverter

Olimpia Splendid Unico Pro Inverter User Manual - English, German, Dutch - 272 pages

Olimpia Splendid Unico Pro Inverter User Manual - Dutch - 46 pages

Olimpia Splendid Unico Pro Inverter User Manual - French, Italian, Swedish, Spanish - 272 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info