5. COMMISSIONING
5.1 Mount the glass plate onto the tower
Press 2 sec. on key
to move the tower up. Take the tower assembly from the cooking plate by pulling it up and place
the tower on the table top. Take the loose glass plate and place it with a turning movement onto the tower (drawing 9
and 10).
5.2 User modes
The unit is by default set for operation in the recirculation mode. If an exhaust to the outside is used anyway, disable the
indicator for saturated recirculation filter as follows:
CHANGE SETTING FOR EXHAUST DUCT TO THE OUTSIDE:
Only disable the programming when mounting an exhaust duct to the outside.
This setting can only be changed when the tower has been disabled and therefore is in the most downward position.
Simultaneously press the key combination [
], [ ], [ ] for 3 seconds until the LED beside the blinks 3 times
SETTING BACK TO RECIRCULATION:
Simultaneously press the key combination [
], [ ], [ ]for 3 seconds until the LED beside the lights up for 3
seconds
5.3 Limitation maximum power induction hob (only for 1801 One Power)
The hob can be equipped with a power limitation. If you reach the maximum power it will be impossible to increase the
power on the different cooking zones and a beep signal will sound. This limitation is set at 7400W (32A) by the factory but
it is possible to change it to 4800W (20A) or 3000W (12A).
Before beginning the procedure:
Make sure there is no more pot on the hob
Disconnect the appliance from the grid by removing the fuse or turning the circuit breaker off.
Reconnect the table to the grid
Start the procedure within 2 minutes after reconnecting the hob to the grid
Make sure all cooking zones are off.
Procedure:
1) Press simultaneously on both zone selection keys of the
bottom zones during 3 seconds. A beep will sound and the
current power is displayed.
2) To set the power limitation use the [ + ] and [ - ]. To exit the
procedure without saving your changes, don’t touch any
key for 60 seconds.
3) To save the new power limitation, press simultaneously
on both zone selection keys of the bottom zones during
3 seconds. Once the new limitation registered, a beep will
sound.
6. ACCESSOIRIES
The following accessories can be ordered with the unit:
Wall passage for flat duct. Inox/SS incl. non-return valve:
article 906407
Outside wall grate round duct Ø 150 mm. Aluminium shutter
grate: article 906178
Non-return valve round duct Ø 150 mm: article 906269
Aluminium tape, roll 50 metres: article 906292
OPTIONAL (1801 One Power & 1811 One Pro from v13)
Installation I/O module n° 990034
Open the cover of the electrical connection box.
Plug in the I/O module connection cable into the connector.
(See manual 990034 I/O module)
EN 23
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Novy 1801 One Power at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Novy 1801 One Power in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 0,45 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Novy 1801 One Power

Novy 1801 One Power User Manual - English, German, Dutch, French - 74 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info