3.2 Exhaust duct to the outside
The motor outlet has a rectangular exhaust of 220 x 90 mm. It is recommended to connect an exhaust duct to this with
the same dimensions (drawing 8).
For optimum performance of the hood it is important to pay attention to the items mentioned below.
When using a flat exhaust duct:
Use flat ducts with rounded corners and air conductors in the bends. These ducts are to be obtained through Novy.
An adapter makes it possible to change from a flat to a round exhaust duct.
When using a round exhaust duct:
Use smooth, non-flammable pipes with an internal diameter that is equal to the external diameter of the connection
nozzle of the hood. Maximally extend flexible ducts and cut them to size.
Do not reduce the exhaust diameter. This will decrease the capacity and increase the noise level.
When connecting to a short exhaust duct, it may be required to mount a non-return valve to prevent the wind from
blowing in.
Use a hose clamp or aluminium tape for airtight connections.
In case of an exhaust pipe through the outside wall, use the outside wall grate.
General:
Make the duct as short as possible and with as few as possible bends to the outside.
Avoid square bends. Use rounded bends for proper air conduction.
If an exhaust pipe through the outside wall passes a cavity wall, make sure that the exhaust duct fully bridges the
cavity and slightly declines to the outside.
In case of an exhaust pipe through the roof, use a double-walled roof passage with sufficient width.
Never connect the exhaust to a flue duct.
Make sure that sufficient air is supplied. Fresh air can be supplied by slightly opening a window or an outside door or
by installing an inlet grate.
The unit is by default set to recirculation. Disable the recirculation program in case of exhaust to the outside (5.2).
4. ELECTRICAL CONNECTION
The installation and connection to the electricity grid shall only be carried out by an expert (electrician) who is
familiar with the required standards.
The junction box is to be found at the bottom of the cooking plate. Use a screwdriver to open the cover and place this in
the 2 grooves before the arrows.
Disable the main switch of the fuse concerned before connecting the unit.
Connect the unit in accordance with the table and diagram below.
Mains Connection Supply cord Circuit braker Wiring diagram
230V 50/60Hz 1 phase + N 3 x 6 mm² 32 A
230V 50/60Hz 3 phases 4 x 6 mm² 20 A
400V 50/60 Hz 2 phases + N 4 x 4 mm² 16 A
400V 50/60 Hz 3 phases + N 5 x 4 mm² 16 A
Attention! Properly put through the wires and tighten the screws.
We will not accept any responsibility for accidents resulting from a poor or wrong connection or accidents that may occur
with units without or with a defective earthing.
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Novy 1801 One Power at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Novy 1801 One Power in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 0,45 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Novy 1801 One Power

Novy 1801 One Power User Manual - English, German, Dutch, French - 74 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info