619206
8
Zoom out
Zoom in
Previous page
1/12
Next page
nv Niko sa Industriepark West 40, BE-9100 Sint-Niklaas, Belgium — tel. +32 3 778 90 00 — fax +32 3 777 71 20 — e-mail: support@niko.be — www.niko.eu PM350-20065R12235
350-20065
7. TECHNISCHE DATEN
Abmessungen 60 x 120 mm (HxB)
Versorgungsspannung 230 Vac ± 10%, 50 Hz
Leistungsaufnahme 1 W
Relaiskontakt Schließer (max. 10 A, 230 V), potentialfrei, licht-
und bewegungsempfindlich
maximale Belastung Glühlampen (2300 W)
230 V-Halogenlampen (2300 W)
alle Niederspannungs-Halogenlampen (2300 W)
Leuchtstofflampen (unkompensiert) (1200 VA)
Energiesparlampen (CFLi) (58 x 18 W)
maximale Schaltleistung 140 μF
maximaler Einschaltspitzenstrom 165 A/20 ms
Erfassungswinkel 360°
Montagehöhe 2 – 3 m
Erfassungsbereich US: 10 x 16 m (138 m²)
PIR: ø 8 m (50 m²)
Lichtempfindlichkeit 10 – 1000 Lux
Ausschaltverzögerung 1 – 30 min
Schutzart IP20
Schutzklasse Geräteklasse I
Umgebungstemperatur 0 – 45°C
Leitungsdurchführung 2 x 12 mm
Prüfzeichen CE-Kennzeichnung gemäß EN 60669-2-1
Zubehör IR-Fernbedienung (350-20067)
8. WARNHINWEISE FÜR DIE INSTALLATION
- Die Installation darf ausschließlich von einer Elektrofachkraft unter Berücksichtigung der geltenden
Vorschriften ausgeführt werden.
-
Diese Gebrauchsanleitung muss dem Benutzer ausgehändigt werden. Die Gebrauchsanleitung ist den Unterlagen
der elektrischen Anlage beizufügen und muss auch eventuellen neuen Besitzern ausgehändigt werden.
Zusätzliche Exemplare erhalten Sie über die Internetseiten von Niko oder über den Kundendienst von Niko.
- Beachten und berücksichtigen Sie bei der Installation unter anderem folgende Punkte:
- die gültigen Gesetze, Normen und Richtlinien.
- den Stand der Technik zum Zeitpunkt der Installation.
- die in dieser Gebrauchsanleitung aufgeführten Anweisungen, wobei diese Gebrauchsanleitung nur
allgemein gültige Bestimmungen enthält, die für jede Anlage spezifisch angewendet werden müssen.
- die allgemein anerkannten Regeln fachmännischer Arbeit.
9. NIKO UNTERSTÜTZUNG
Bei Zweifel oder falls Sie bei einem eventuellen Defekt des Produkts noch Fragen bezüglich des Umtausches
haben, dann nehmen Sie bitte Kontakt auf mit dem Kundendienst von Niko (Belgien: +32 3 778 90 80) oder
wenden Sie sich an Ihren Großhändler. Kontaktdaten und weitere Informationen erhalten Sie im Internet unter
www.niko.eu in der Rubrik “Unterstützung und Beratung”.
10. GARANTIEBEDINGUNGEN
- Der Garantiezeitraum beträgt vier Jahre ab Lieferdatum. Als Lieferdatum gilt das Rechnungsdatum
zum Zeitpunkt des Kaufs durch den Endverbraucher. Falls keine Rechnung mehr vorhanden ist, gilt das
Produktionsdatum.
- Der Endverbraucher ist verpflichtet, Niko schriftlich über einen Produktmangel innerhalb von zwei Monaten
nach dessen Feststellung zu informieren.
- Im Falle eines Mangels hat der Endverbraucher nur Recht auf kostenlose Reparatur oder Ersatz des
Produkts. Eine Entscheidung darüber obliegt allein Niko.
- Niko ist nicht für Mängel oder Schäden verantwortlich, die durch fehlerhafte Installation, nicht
bestimmungsgemäßen oder unsachgemäßen Gebrauch, durch falsche Bedienung, Anpassen/Ändern des
Produktes, infolge von unsachgemäßer Wartung entgegen den Wartungsvorschriften oder die sich aus
äußeren Umständen, wie beispielsweise infolge Feuchtigkeit oder Überspannung, ergeben.
-
Zwingende Vorschriften der nationalen Gesetzgebung bezüglich des Verkaufs von Konsumgütern und zum
Verbraucherschutz haben vor den obigen Bestimmungen Vorrang in den Ländern, in denen Niko direkt oder über
seine Neben- oder Tochtergesellschaften, Filialen, Vertriebsstellen, Agenten oder über feste Vertreter verkauft.
Read the complete user manual before carrying out the installation and activating the system.
1. DESCRIPTION
The presence detector Dual Tech 360° (master) integrates advanced Passive Infrared Technology (PIR) and
Ultrasonic (US) Technology in one single device. Combining these technologies prevents false triggering, even
in difficult applications. The presence detector is suitable for indoor use, e.g. in open plan offices, public toilets,
conference rooms, underground car parks, classrooms and libraries.
This presence detector can be used as a master (standalone), in combination with one or more slaves, and can
be connected to an external push button.
The switch-off delay, sensor sensitivity, lux value, air flow sensitivity and detection method can be set using the
potentiometers on the presence detector or via the IR remote control (not included) (350-20067).
2. INSTALLATION
2.1. Connection
Danger: Disconnect all power before installing the presence detector. Do not connect the device to the mains
voltage until installation has been completed.
A. Standalone
Refer to the wiring diagram (fig. 1).
B. In combination with one or more slaves
Refer to the wiring diagram (fig. 2).
C. Use of an external push button
You connect an external push button to the presence detector if you must also be able to control the device
manually. You can connect the push button only to the master.
Follow the wiring diagram (fig. 3) to connect the push button.
2.2. Mounting
Tip: Do not install the presence detector in the vicinity of heat sources such as stoves or electric heaters,
air currents (ventilation systems) or moving objects. Also avoid reflective surfaces such as large windows
or glass partition walls (fig. 4). This can activate the device unnecessarily because the device reacts to
movement and heat in its environment.
Tip: Ideally, the presence detector should be mounted onto the ceiling. If the device is mounted below ceiling
level, the ultrasonic detection range will be reduced.
Tip: The recommended mounting height is 2 to 3 m. The presence detector performs optimally when
mounted at a height of 2.5 m.
The presence detector is suitable for:
• ushmountingwithastandardush-mountingbox,or
• surfacemountingusingthesurface-mountingbase.Whenusingthesurface-mountingbase,youcan
use any of the seven pairs of fixing holes with various distances from 41 to 85 mm.
3. SETTINGS
The presence detector can be used with standard factory settings (see section 3.1.) or you can modify
the settings (see section 3.2.) using the potentiometers on the device or the IR remote control.
3.1. Factory settings
At delivery the parameters of the presence detector Dual Tech 360° (master) are set as follows:
Parameter Factory setting
light sensitivity 100 lux
switch-off delay 15 min
detection area (sensitivity of the ultrasonic sensor) 80%, ± 8 x 13 m
detection method PIR+US
air flow sensitivity off
3.2. Modifying settings
A. Using the potentiometers
Underneath the housing of the presence detector, you will find five potentiometers that can be used to modify
the parameters as you prefer (fig. 5).
Potentiometer Function
Setting the light level (light sensitivity) at which
the lights must be switched on. 10, 100, 300 and
1000 lux are approximate values.
Setting the switch-off delay. There are six preset
values:
-
1 minute
- 5 minutes
- 15 minutes
- 30 minutes
- pulse: interval of 1 second on, 9 seconds off
- test mode: the lighting is switched on for two
seconds whenever motion is detected
Setting the detection range. There are four preset
values:
- – (minimum setting): ± 2 x 3 m
- ± 4 x 6 m
- ± 7 x 8 m
- + (maximum setting): ± 10 x 16 m
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Niko 350-20065 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Niko 350-20065 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 5,71 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info