500096
1
Zoom out
Zoom in
Previous page
1/2
Next page
Battery backup system
DC power: 9V battery type 6F22 (not provided) for clock and alarm time backup system
only.
An alkaline type battery is recommended. For optimum performance this battery should
be replaced every 6 months.
Note: if no battery is installed or if the battery is low, “ ” indicator is displayed (2).
Connect the 9V battery inside the compartment (14) at the back of the unit.
BACKUP SYSTEM: Ensures that the unit continues to operate during an AC power
disruption (in order to preserve the battery life, the display is switched off). All clock,
date and alarm settings will be kept in the memory, however, the clock time may
require adjustment for exact accuracy. If no battery is installed, the display will blink to
indicate that you have to reset the time and alarm.
1. Slide the SETTING mode switch (19) to CLOCK position, press / (10) to
select the time mode between 12hours and 24hours, press DATE/SET (5) to confirm .
Then the hour digits will flash, press / (10) to adjust the value. The time
decrements or increments at a faster rate when you press and hold the buttons. Confirm
with DATE/SET (5). Repeat this procedure for the minute, year, sequence (D-M or M-
D) and value of day (“D”) and month (“M”)
1. ON/OFF button
2. LCD display
3. ALM.1 button
4. ALM.2 button
5. DATE/SET button
6. NAP button
7. SLEEP button
8. Speaker
9. Projector
10. SNOOZE/ / button
11. Projector ON/OFF switch
SETTING THE TIME
GB - 1 GB - 2
GB - 4GB - 3
INDOOR / OUTDOOR TEMPERATURE
GB - 5
M-180CR
User Manual
In/Out temperature projection clock radio
PLEASE READ THE INSTRUCTION CAREFULLY
BEFORE OPERATING THE UNIT
English
UNPACKING YOUR UNIT
When you unpack your new clock radio, make sure that you have removed all the
accessories and information papers:
- Projection clock radio
- AC/DC adaptor
- External temperature remote sensor with transparent cover and wall bracket
- User manual
PRODUCT DESCRIPTION
Location of controls
12. ROTATE button (for projected
image)
13. ºC / ºF button
14. Battery backup compartment
15. 5V DC in jack
16. Volume control
17. Band selector: MW/FM
18. Tuning knob
19. SETTING mode selector: CLOCK/
ALM.1/ALM.2/LOCK
20. FM wire antenna
21. Indoor temperature sensor
LCD display
POWER SUPPLY
AC/DC adaptor
- The supplied AC/DC adaptor is suitable
for use on AC mains supplies of 230V~
50Hz and should only be connected to a
mains supply with these parameters.
Caution:
- The included AC/DC adaptor is for use
with this unit only. Do not use it with other
equipments.
- When the unit is not going to be used for
long time, disconnect the AC/DC adaptor
from the AC outlet.
- Be sure to use it near the wall outlet. If a
malfunction occurs, disconnect the plug
from the wall outlet at once.
- When the AC/DC adaptor is plugged in, the apparatus is not completely disconnected
from the main power source, even when the unit is turned off.
- The AC/DC adaptor shall not be exposed to dripping or splashing and that no objects
filled with liquids, such as vases, shall be placed on apparatus.
- To be completely disconnect the power input, the AC/DC adaptor of apparatus shall
disconnected from the mains.” as the disconnect devices is the AC/DC adaptor of
apparatus.
- The AC/DC adaptor of apparatus should not be obstructed OR should be easily accessed
during intended use.”
Note: Pressing DATE/SET button (5) again, enters a new setting cycle.
Once the unit is plugged in, it will enter the time setting mode. ”24Hr” blinks on display.
2. Slide the SETTING mode switch (19) to LOCK position. The calendar is viewed for
3 seconds and display resumes to clock mode.
Pressing DATE/SET (5) displays the calendar for 3 seconds
Indoor temperatare
Once the unit is connected, the indoor temperature is displayed (2).
Celsius (ºC) and Fahrenheit (ºF).degrees selection
The button (13) switches the unit for both indoor and outdoor temperature
between Celsius (ºC) and Fahrenheit (ºF) degrees.
Outdoor temperature
1. Remote sensor set-up
- Remove the wall bracket.
- Unlock two latches at the bottom to release the transparent cover.
- Slide down the battery door at the back.
- Insert 2 batteries, type R03/UM4/AAA (not provided). Follow the polarity indicated in
the battery compartment
- An alkaline type battery is recommended. For optimum performance this battery should
be replaced every 6 months.
2. Remote sensor synchronization
- To enter synchronization mode, press and hold (10) for 3 seconds on the main
unit, “ ” flashes on the display (2) for 2 minutes.
- Press RESET button of the remote sensor with pointed object (such as ball-point
pen). The LED blinks
- A few seconds later the temperature will appear on the display of the main unit.
- To exit synchronization mode, press button (10), “ ” is not displayed.
Note:
* To synchronize remote sensor and main unit on a different channel, press CH button
and repeat synchronization operations.
* Once connected, the unit enters in synchronization mode with the remote sensor for
2 minutes. “ ” flashes on the display.
3. Replace battery door and transparent cover, lock the 2 latches at the bottom. Install
the remote sensor within a range of 50 meters from main unit in open area.
4. “ ”on the outdoor temperature area of the display, indicates that the remote
sensor batteries are low. Replace them with new batteries.
After battery replacement, or after main unit reset, or if the sensor is under the influence
of electrical fast transient or/and electrostatic phenomenon, reset the remote sensor
with the RESET button.
Note:
* If the unit fails to received the outdoor temperature for 10 minutes, it will display
- - . - “ .
* Displayed temperature and remote sensor operating range: -10.0°C to +60.0°C (+14.
0°F to +140.0°F)
未命名-1 2009-9-8, 16:171
1


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Muse M-180 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Muse M-180 in the language / languages: English as an attachment in your email.

The manual is 1,29 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Muse M-180

Muse M-180 User Manual - Dutch - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info