726079
67
Zoom out
Zoom in
Previous page
1/72
Next page
67
2.4.2 Installation Location and Installation Requirements
(1). Do not install the wired controller in the damp place or under direct sunlight.
(2). Do not install the wired controller close to the hi-temperature object or place where the
wired controller is likely to suffer water spray.
(3). Do not install the wired controller directly opposite to the window so as to avoid improper
operation caused by the interference of the neighbor’s same model wired controller.
(4). Please cut off the power supply of wires embedded in the wall. No operation is allowed with
electricity.
(5). To avoid abnormal operation caused by electromagnetic interference or other causes,
please take notice of the following statements during wiring.
.
Be sure the communication line is wired into the correct port, otherwise it would result in
communication fault.
.
The communication line (wired controller) and power line must be separated with the
minimal distance of 20cm, otherwise it would result in communication fault.
.
Suppose that the air conditioner is installed where likely to suffer electromagnetic
interference, the communication line of the wired controller must be shielded twisted pair.
2.4.3 How to Install the Wired Controller
First of all, the selection and connecting method of the communication line is shown as follows:
(1). Select appropriate communication line of the wired controller: 2-core signal line (wire
size0.75mm
2
, length<30m, recommended length: 8m).
(2). After the indoor unit is de-energized, fix the communication line on the indoor terminal
board by screws.
Then, the specific installation steps is shown in the Fig.27:
Fig.27 Installation of the Wired Controller
Cassette Serie H3 - Super DC Inverter
67


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for MundoClima MUCSR-H3 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of MundoClima MUCSR-H3 in the language / languages: English as an attachment in your email.

The manual is 7,26 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info