683950
5
Zoom out
Zoom in
Previous page
1/8
Next page
BA SC9840knx Anwendungsprogramm HM, DE GB - 23265 - ED - V02
INSTRUCTION MANUAL ENGLISH - PAGE 1 / 4
ENGLISH
Application program
„SC 98.40 knx„
Usage: KNX yearly time switch SC 98.40 knx
Usage:
The time switch can send following datapoints to the bus:
Switching [1 bit]: Time dependent switching
Priority [2 bit]: Priority/control based switching
Value [1 byte]: Transmits a 1 byte integer number
Value [2 byte]: Transmits a 2 byte integer number
Float [2 byte]: Transmits a 2 byte floating point number
Float [4 byte]: Transmits a 4 byte floating point number
Scene control [1 byte]: Up to 64 scenes
HVAC [1 byte]: Heating, ventilating and air conditioning
4x Logic Gates: With AND/OR/XOR and/or with FEEDBACK LOOP. Up to 4 different input values
possible which can be internal (time switch, output of other logic gates) and external
(from the bus) 1 bit values. Output can be 1 bit and 1 byte data values.
Please note:
For operation and installation refer to the instruction manual of the time switch!
Synchronization of DST-change may take up to 1 minute.
Please take into account the resolution of the 2-byte data types (please check the KNX specification)!
Numbers can be entered as follows: E.g. 2e1 = 20 or e.g. 4,321e3 = 4321
Technical data: KNX yearly time switch SC 98.40 knx
Power Supply:
via KNX bus voltage (nominal voltage 29V)
Bus current:
max. 25 mA
Bus system:
KNX
Type of protection:
IP 20 to DIN EN 60529
Permitted ambient temp.:
-30°C … 55°C
Certification mark:
CE
Housing:
self-extinguishing thermoplast
Assembly:
35 mm section rails (DIN EN 60715)
Type of connection:
KNX bus terminal
Rights to technical amendments reserved
Application program
Manufacturer:
Hugo Müller GmbH & Co KG
Program name:
Test Project SC98.40 knx V1.8
Installation:
Please install the application program as test project!
Communication objects 1 - 51
Number
Name
Datentyp
0
Date
11.001 Date
1
Time
10.001 Time of day
3
Request date/time
1.017 1 Bit
4
Switch channel A
1.001 1 Bit
5
Switch channel B
1.001 1 Bit
6
Switch channel C
1.001 1 Bit
7
Switch channel D
1.001 1 Bit
8
Priority Channel A
2.* 2 Bit
9
Priority Channel B
2.* 2 Bit
10
Priority Channel C
2.* 2 Bit
11
Priority Channel D
2.* 2 Bit
12
Integer 1 byte channel A
5.* 1 Byte
13
Integer 1 byte channel B
5.* 1 Byte
14
Integer 1 byte channel C
5.* 1 Byte
15
Integer 1 byte channel D
5.* 1 Byte
16
Integer 2 byte channel A
7.* 2 Byte
17
Integer 2 byte channel B
7.* 2 Byte
18
Integer 2 byte channel C
7.* 2 Byte
19
Integer 2 byte channel D
7.* 2 Byte
20
Float 2 byte channel A
9.* 2 Byte
21
Float 2 byte channel B
9.* 2 Byte
22
Float 2 byte channel C
9.* 2 Byte
23
Float 2 byte channel D
9.* 2 Byte
24
Float 4 byte channel A
14.* 4 Byte
25
Float 4 byte channel B
14.* 4 Byte
26
Float 4 byte channel C
14.* 4 Byte
27
Float 4 byte channel D
14.* 4 Byte
28
Scene channel A
17.001 Scene no.
29
Scene channel B
17.001 Scene no.
30
Scene channel C
17.001 Scene no.
31
Scene channel D
17.001 Scene no.
32
HVAC channel A
20.102 HVAC
33
HVAC channel B
20.102 HVAC
34
HVAC channel C
20.102 HVAC
35
HVAC channel D
20.102 HVAC
36
Priority value channel A OFF
1.003 1 Bit
37
Priority value channel A ON
1.003 1 Bit
38
Priority value channel B OFF
1.003 1 Bit
39
Priority value channel B ON
1.003 1 Bit
40
Priority value channel C OFF
1.003 1 Bit
41
Priority value channel C ON
1.003 1 Bit
42
Priority value channel D OFF
1.003 1 Bit
43
Priority value channel D ON
1.003 1 Bit
44
Integer value 1 byte channel A OFF
5.* 1 Byte
45
Integer value 1 byte channel A ON
5.* 1 Byte
46
Integer value 1 byte channel B OFF
5.* 1 Byte
47
Integer value 1 byte channel B ON
5.* 1 Byte
48
Integer value 1 byte channel C OFF
5.* 1 Byte
49
Integer value 1 byte channel C ON
5.* 1 Byte
50
Integer value 1 byte channel D OFF
5.* 1 Byte
51
Integer value 1 byte channel D ON
5.* 1 Byte
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Muller SC 98.40 knx at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Muller SC 98.40 knx in the language / languages: English, German as an attachment in your email.

The manual is 1,05 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Muller SC 98.40 knx

Muller SC 98.40 knx User Manual - English, German - 4 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info