BA LS30knx HARDWARE N; DE,GB -23338-ED-V01
KNX light and
temperature sensor
Safety issues
Usage
!!ATTENTION!! DANGER OF LIFE / RISK OF FIRE AND ELECTRIC
SHOCK!!
=> Installation and assembly of electrical equipment must be carried out only
by professional electrician!
=> Disconnect device from power supply for wiring and installation purposes!
=> Defective devices have to be put out of service immediately!!!
Connect only to suitable supply voltage/frequency. Only operate the KNX
light sensor with extra-low voltage!
Warranty void if housing opened by unauthorised person!
The electronic circuit is protected against a wide range of external influences.
Incorrect operating may occur if external influences exceed certain limits!
Installation and assembly of electrical equipment must be in accordance with
national building, electrical and safety codes!
Observe the regulations and instructions in the ZVEI/ZVEH handbook
(building system technology). Especially the professional installation of the
bus lines and the professional installation and start-up of KNX devices must
be observed!
Usage:
TheKNX light and temperature sensor can send the
following data to the KNX bus: Outside temperature / Lux
values
Following data and functions will be offered for the KNX bus
(via ETS): Temperature control, light control, twilight switch
with daily program, daily time switch
Technical data
Power Supply:
via KNX bus voltage (nominal voltage 29V)
Bus current:
approx. 10 mA
Bus system:
KNX
Type of protection:
IP 54 (DIN EN 60529)
Permitted ambient temperature:
-30°C 5C
Specifications // Compliance:
EN 60730 // CE
Housing:
self-extinguishing thermoplast
Assembly:
wall mounting with mounting bracket
Type of connection:
KNX bus terminal
Rights to technical amendments reserved
Installation instruction
Make sure that there are no transformers, relays, switches, or similar devices within a radius of one meter around the KNX light and temperature sensor.
If mounted on wall, avoid electric cables and other disturbing metal in the wall.
Installation and connection of the device
Connection / wall mounting
Remove both screws on the bottom side and remove the bottom cover.
Guide wire through the cable sleeve and the hole of the bottom cover.
Connect the wire to the removable BUS terminal block (Please note polarity).
Plug BUS terminal block to pins on PCB
Program the KNX light and temperature sensor (please see pointConfiguration).
Assemble cable sleeve on the bottom cover.
Screw the bottom cover.
Install wall mounting bracket and attach the KNX light and temperature sensor (see drilling plan).
Configuration
The parameterization will be assigned by the ETS-software: Physical address, group address, parameter settings
Programming the KNX light and temperature sensor
Press the learning key
RESULT => The KNX-LED lights up (until the ETS-software programs the KNX light and temperature sensor)
PLEASE NOTE => You can confirm the correct programming with the ETS-software
Take care of the environment!
Recycle properly!
Drilling plan for wall mounting bracket [ NOT TRUE TO SCALE ]
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Muller LS 30.00 knx at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Muller LS 30.00 knx in the language / languages: English, German as an attachment in your email.

The manual is 0,28 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Muller LS 30.00 knx

Muller LS 30.00 knx Installation Guide - English, German - 4 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info