MI 3394 CE MultiTesterXA Appendix D
132
Description: Instrument sends string to external device at
the end of each Measurement step. End + Status Flow
setting is disabled by default.
Alarm
Recived string:
Alarm
Description: Instrument sends “Alarm” string to external
device if “empty” status is detected and if both conditions -
“Fail” status at the end of measurement step and flow
command OPERATION AFTER END OF TEST fail is
set to “manual”. Alarm Flow setting is disabled by default.
Operation after end of test
This flow command controls the proceeding of the Auto Sequence® in regard to the
measurement results.
Parameters
Operation after end of test
pass
fail
no status
The operation can be individually set for the case the
measurement passed, failed or ended without a status.
Manual:
The test sequence stops and waits for apropriate
command (TEST key, external command...) to
proceed.
Auto:
The test sequence automatically proceeds.
Result screen
This flow command controls the proceeding after the Auto Sequence® has ended.
Parameters
Local Save
Auto Sequence® is stored in the momentary workspace.
A new Node with the date and time will be created. Under
the Node results of the Auto Sequence® or (if Appliance
info flow command is set) a new appliance and the
results of the Auto Sequence® will be stored.
Up to 100 results of Auto Sequence® or appliances can
be automatically stored under the same node. If more
results / appliances are available, they are split to multiple
nodes.
Local Save Flow setting is disabled by default.
Notes
This flow command is active only if Auto
Sequence® is started from the Auto Sequences®
Main menu (not from Memory organizer).
133


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Metrel MI 3394 - CE MultiTesterXA at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Metrel MI 3394 - CE MultiTesterXA in the language / languages: English as an attachment in your email.

The manual is 4.74 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Metrel MI 3394 - CE MultiTesterXA

Metrel MI 3394 - CE MultiTesterXA User Manual - German - 110 pages

Metrel MI 3394 - CE MultiTesterXA Additional guide - Dutch - 1 pages

Metrel MI 3394 - CE MultiTesterXA User Manual - Dutch - 5 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info