168729
4
Zoom out
Zoom in
Previous page
1/88
Next page
4
AMPLIFIER FEATURE DESCRIPTION
- Each model is capable of 4 & 2 ohms stereo per channel, or 4
ohms mono bridged operation.
- Tri-Mode operation with any stereo pair of amplifi er channels is
possible, as with all bridgeable amplifi ers.
- The input sensitivities for rated output powers are variable from
0.2 volt to 6 volt.
- All crossovers are fully variable in their respective ranges.
- Crossover fi lter slopes are 12 dB/octave for stereo fi lters, and 24
dB/octave for mono fi lters.
- A POWER LED indicates the powered “up” and turned “on” condi-
tion.
MBQR-1
MBQR-1
PAB 4100 4-Channel Amplifi er
INPUT MODE slide switch:
- In the CH2 position, ALL four amplifi er inputs are selected from the
CH1/CH2 RCA jacks.
- In the 4CH position, channel pair 1&2 receive input signal from
RCA jacks CH1 and CH2, and channel pair 3&4 receive input signal
from RCA jacks CH3 and CH4.
The AMPLIFIER CH 1/2CH X-OVER slide switch selects the input
signal for channel pair 1&2:
- HP: Selects the built in HIGH PASS fi lter, variable from 10 Hz to
150 Hz.
- FULL: Bypasses all crossovers for full frequency range operation.
- BP: Selects the built in LOW PASS fi lter, variable from 30 Hz to
150 Hz.
Note that the LOW PASS signal is MONO.
- In the BP position, the HIGH PASS fi lter acts as a subsonic fi lter.
- When the BP mode is selected, a 0 to +9 dB, at 45 Hz, BASS EQ is
also switched in.
Premium Multi-Channel Amplifiers
PAB 2100 2-Channel Amplifi er
The X-OVER slide switch selects the internal crossover functions:
- The input signal is routed directly to the LINE OUT RCA jacks, regardless of the X-OVER setting simplifying daisy chaining of amplifi er.
- HP: Selects the built in HIGH PASS fi lter, variable from 10 Hz to 150 Hz.
- FULL: Bypasses all crossovers for full frequency range operation.
- LP: Selects the built in LOW PASS fi lter, variable from 30 Hz to 150 Hz.
Note that the LOW PASS signal is MONO.
- In the LP position, the HIGH PASS fi lter acts as a subsonic fi lter.
- When the LP mode is selected, a 0 to +9 dB, at 45 Hz, BASS EQ is also switched
The AMPLIFIER CH 3/CH 4 X-OVER slide switch selects the input
signal for channel pair 3&4:
- Hi: Selects the built in HIGH PASS fi lter, variable from 10 Hz to
150 Hz.
- FULL: Bypasses all crossovers for full frequency range operation.
- BP: Selects the built in LOW PASS fi lter, variable from 30 Hz to
150 Hz.
Note that the LOW PASS signal is MONO.
- In the BP position, the HIGH PASS fi lter acts as a subsonic fi lter.
- When the BP mode is selected, a 0 to +9 dB, at 45 Hz, BASS EQ is
also switched in.
- Full range signal from channels 1/2 inputs are routed to the Line
OUT RCA jacks, regardless of the setting of the X-OVER switches.
- The REMOTE jack enables dash mount level control of the LOW
PASS signal, CH3/4 only.
- All MB QUART Premium amplifi ers feature a comprehensive dia-
gnostic system, with speaker lead short circuit, and amplifi er DC
faults indicated by the DIAGNOSTIC, or PROTECT LED.
CAUTION:
DO NOT OPERATE ANY AMPLIFIER BELOW THE INTENDED IM-
PEDANCE. YOU WILL CAUSE DAMAGE TO THE AMPLIFIER THAT
WILL NOT BE COVERED UNDER THE WARRANTY PRINTED IN THE
BACK OF THE MANUAL.
Multi-Channel amps: 4 & 2 ohms stereo, 4 ohms mono bridged
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for MB Quart pab 4100 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of MB Quart pab 4100 in the language / languages: English, German, French, Spanish as an attachment in your email.

The manual is 11,32 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info