785665
95
Zoom out
Zoom in
Previous page
1/108
Next page
ESPAÑOL
95
Panel de control del inversor AC Master (opcional)
Opcionalmente, se usa un panel de control del inversor AC Master (referencia: 70405080)
conectado al puerto remoto (RS-232). En el caso de un sistema con varias unidades: Conecte
siempre el panel de control a la unidad maestra. Antes de usar el panel de control, asegúrese de
que el interruptor principal de la unidad conectada esté en la posición «REMOTE» antes de la
puesta en marcha.
Terminal para interruptor remoto y terminación CAN
Este terminal ofrece dos funciones:
Interruptor remoto
Instale un interruptor para el funcionamiento remoto. En el caso de un sistema con varias
unidades: Conecte siempre el interruptor remoto a la unidad maestra. Asegúrese de que el
interruptor principal de la unidad conectada esté en la posición «REMOTE».
Puente para terminación CAN
Un bus CAN requiere dos puntos de terminación: uno al inicio y otro al final del bus. El AC
Master 2500-3500 está equipado con un puente que activa o desactiva el resistor de la
terminación CAN (puente cerrado = terminación activa; puente abierto = terminación no activa).
La terminación CAN es necesaria para sistemas de varias unidades; consulte la sección 10.
Interruptor remoto
1 Tierra (GND)
(misma polaridad con entrada de batería
negativa)
2Habilitar (ENB)
3 Habilitar + (ENB)
Puente para terminación CAN
4 Ranura de puente
5 Ranura de puente
95

Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Mastervolt AC Master 12 2500 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Mastervolt AC Master 12 2500 in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 4,15 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info