Hardware
Power supply 12 V DC, external power adapter (230 V); bayonet connector to secure against disconnection
Power consumption Max. ca. 14 W
Environment Temperature range 0–40 °C; humidity 0–95 %; non-condensing
Housing Robust synthetic housing, rear connectors, ready for wall mounting, Kensington lock; measures
210 x 45 x 140 mm (W x H x D)
Number of fans None; fanless design, no rotating parts, high MTBF
Interfaces
WAN: VDSL2 A VDSL2 as per ITU G.993.2; proles 8a, 8b, 8c, 8d, 12a, 12b, 17a
A Compatible to VDSL2 from Deutsche Telekom
A ADSL conformity according to: ADSL2+ over ISDN as per ITU G.992.5 Annex B/J with DPBO,
ADSL2 over ISDN as per ITU G.992.3 Annex B, ADSL over ISDN as per ITU G.992.1 Annex B.
A Supports just one virtual connection at a time in ATM (VPI-VCI pair)
ETH 4 individual ports, 10 / 100 / 1000 Mbps Gigabit Ethernet, by default set to switch mode.
Up to 3 ports can be operated as additional WAN ports. Ethernet ports can be electrically
disabled in the LCOS conguration.
USB USB 2.0 hi-speed host port for connecting USB printers (USB print server),
serial devices (COM-port server) or USB drives (FAT le system).
ISDN 1 / ISDN 2
ISDN 3 / ISDN 4
ISDN 1+2: Internal (NT) or external (TE) ISDN bus. This feature is controlled by LCOS.
According to the settings, connect the light-blue ISDN cable either to the NTBA or the ISDN
terminal device.
ISDN 3+4: Internal (NT) ISDN bus. Use the light-blue ISDN cable to connect the ISDN device to
the ISDN interface.
Cong (Com) / V.24 Serial conguration interface / COM-port (8-pin mini-DIN): 9,600 - 115,200 baud, suitable
for optional connection of analog / GPRS modems. Supports internal COM-port server and
provides transparent asynchronous serial-data transfer via TCP.
WAN protocols
VDSL, ADSL, Ethernet PPPoE, PPPoA, IPoA, Multi-PPPoE, ML-PPP, PPTP (PAC or PNS) and IPoE (with or without
DHCP), RIP-1, RIP-2, VLAN
ISDN DSS1 (Euro-ISDN), PPP, X75, HDLC, ML-PPP, V.110/GSM/HSCSD
Declaration of Conformity
Hereby, LANCOM Systems declares that this device is in compliance with Directives 2014/30/EU and 2014/35/EU.
The full text of the EU declaration of conformity is available at the following internet address:
www.lancom-systems.com/ce/
Package content
Documentation Quick Reference Guide (DE/EN), Installation Guide (DE/EN)
Cable 1 Ethernet cable, 3 m (kiwi colored connectors); 1 DSL cable for an IP-based line, 4.25 m;
2 ISDN cables, 3 m (light-blue connectors)
Power adapter External power supply adapter (230 V); NEST 12 V / 1.5 A DC/S; barrel connector 2.1 / 5.5 mm
bayonet; LANCOM item no. 111301
a Power
Off Device switched off
Green, permanently* Device operational, resp. device paired /
claimed and LANCOM Management Cloud
(LMC) accessible
Green / red, blinking No password set. Without a password
the conguration data in the device is
unprotected.
Red, blinking Charge or time limit reached
1x green inverse
blinking*
Connection to the LMC active, pairing OK,
device not claimed
2x green inverse
blinking*
Pairing error, resp. LMC activation code
not available
3x green inverse
blinking*
LMC not accessible, resp. communication
error
b Online
Off WAN connection inactive
Green, permanently WAN connection active
Red, permanently WAN connection error
g VPN
Off VPN connection inactive
Green, permanently VPN connection active
Green, ashing VPN connecting
f VoIP
Off No SIP accounts dened or VCM is off
Green, permanently All dened and active SIP accounts
(outgoing) were successfully registered
Red, permanently Not all of the dened and active SIP
accounts were registered
(possibly still in process)
Red or green,
inverse ashing
Number of currently used lines
(connecting or connected)
c DSL
Off Interface deactivated
Green, permanently DSL connection active
Green, ickering DSL data transfer
Red, ickering DSL transfer error
Red / orange, blinking DSL hardware error
Orange, blinking DSL training
Orange, permanently DSL sync
Green, blinking DSL connecting
d ISDN
Off Interface deactivated
Green, permanently D-channel active
Green, blinking ISDN connected
Red, ickering ISDN transfer error
Red / orange, blinking ISDN hardware error
Red, permanently ISDN connection not enabled
Orange, blinking ISDN connecting
e ETH
Off No networking device attached
Green, permanently Connection to network device
operational, no data trafc
Green, ickering Data transmission
h Reset
Reset switch Operated e.g. with a paper clip
short press > Restart the device
long press > Reset the device
This product contains separate open-source software components which are subject to their own licenses, in particular
the General Public License (GPL). The license information for the device rmware (LCOS) is available on the device‘s
WEBcong interface under “Extras > License information“. If the respective license demands, the source les for the
corresponding software components will be made available on a download server upon request.
a c eb gfd h
LANCOM R884VA
DSL
ETH 2
Power
ETH 1
Online
ISDN 1
ETH 4
ETH 3
VPN
ISDN 2
Reset
ISDN 3
ISDN 4
VoIP
LANCOM R884VA
Quick Reference Guide
Cloud-ready
Gigabit Ethernet 10/100/1000
ISDN 3 ISDN 4
TE / NT NT
ISDN 1 ISDN 2
TE / NT NT
VDSL / ADSL
d e fa b c
4
Please observe the following when setting up the device
A Do not rest any objects on top of the device
A For devices to be operated on the desktop, please attach the
adhesive rubber footpads
A In case of wall mounting, use the drilling template as supplied
A Keep the ventilation slots on the side of the device clear
of obstruction
A Rack installation with the optional LANCOM Rack Mount
(separately available)
LANCOM 1681V
Power
VDSL
Online
ETH 1
ETH 2
VPN
ETH 3
ETH 4
ISDN Status
a
VDSL interface
Use the supplied DSL cable for the IP-based line to connect the
VDSL interface and the provider’s telephone socket. For more
infor mation, please contact your Internet service provider.
b
Ethernet interfaces
Use the cable with the kiwi-colored connectors to connect one of
the interfaces ETH 1 to ETH 4 to your PC, IP telephone or a LAN
switch.
c
Conguration interface
Use a serial conguration cable to connect the serial interface
(COM) to the serial interface of the device you want to use for
conguring / monitoring (separately available).
d
ISDN interfaces
ISDN 1 + 2
Internal (NT) or external (TE) ISDN bus.
This feature is controlled by LCOS.
ISDN 3 + 4
Internal (NT) ISDN bus.
A 100-Ohm resistor
for line termination is
switchable in LCOS.
e
USB interface
You can use the USB interface to connect a USB printer or a
USB memory stick.
f
Power
After connecting the cable to the device, turn the bayonet
connector 90° clockwise until it clicks into place.
Use only the supplied power adapter.
*) The additional power LED statuses are displayed in 5-seconds
rotation if the device is congured to be managed by the LANCOM
Management Cloud.


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Lancom R884VA at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Lancom R884VA in the language / languages: English as an attachment in your email.

The manual is 0,46 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Lancom R884VA

Lancom R884VA Installation Guide - English - 17 pages

Lancom R884VA User Manual - German - 1 pages

Lancom R884VA Installation Guide - German - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info