TECHNICAL DATA
Hardware
Power supply Redundant power supply units (110–230 V, 50–60 Hz)
Power consumption 300 W
Environment Temperature range 5–40 °C; humidity 0–95 %; non-condensing
Housing Robust metal housing, 19“ 1HU, network connectors on the front
Number of fans 4
Interfaces
ETH 8x 100 / 1000 Mbps Gigabit Ethernet combo ports (ETH 1 - ETH 8)
SFP+ 2x 10G SFP+ ports 10 / 1 Gbps (ETH 9 - ETH 10)
USB 2x USB 2.0 Hi-Speed host port for connecting USB printers (USB print server)or USB data
media (FAT le system); bi-directional data exchange is possible (max. 480 Mbps)
Serial Interface Serial conguration interface (RJ45)
WAN protocols
Ethernet PPPoE, Multi-PPPoE, ML-PPP, PPTP (PAC or PNS) and plain Ethernet (with or without DHCP),
VLAN, IP
Declaration of Conformity
Hereby, LANCOM Systems GmbH | Adenauerstrasse 20/B2 | D-52146 Wuerselen, declares that this device is in com-
pliance with Directives 2014/30/EU and 2014/35/EU. The full text of the EU declaration of conformity is available at the
following internet address: www.lancom-systems.com/ce/
Package content
Documentation Quick Reference Guide (DE, EN), Installation Guide (DE/EN)
Accessories 2 Ethernet cables 3 m (kiwi colored connectors); 1 serial conguration cable 1.5 m;
2 IEC power cords 230 V (not for WW devices);
1 set of mounting rails with accessories for xing the device in a 19“ rack; 1x 19“ bracket
MOUNTING AND CONNECTING THE DEVICE
*) The additional status LED statuses are displayed in 5-seconds
rotation if the device is congured to be managed by the LANCOM
Management Cloud.
LANCOM, LANCOM Systems, LCOS, LANcommunity and Hyper Integration are registered trademarks. All other names or descriptions used may be trademarks or registered trademarks
of their owners. This document contains statements relating to future products and their attributes. LANCOM Systems reserves the right to change these without notice. No liability for
technical errors and / or omissions. 111879/0120
LANCOM ISG-8000
Quick Reference Guide
Cloud-ready
a
Serial conguration interface
Use the included serial conguration cable to connect the serial
interface (COM) to the serial interface of the device you want to
use for conguring / monitoring.
b
USB interfaces
You can use the USB interfaces to connect USB printers or USB
storage devices.
c
Reset button
Pressed up to 5 seconds: device restart
Pressed longer than 5 seconds:
conguration reset and device restart
d
TP Ethernet interfaces
Connect the ETH 1 - ETH 8 TP Ethernet interfaces to your PC or a
LAN switch using one of the enclosed cables with the kiwi-colored
connectors.
e
SFP+ interfaces (10G / 1G)
Insert suitable SFP modules into the SFP ports ETH 9 - ETH 10.
Choose cables compatible with the SFP modules and connect
them as described in the module’s documentation.
SFP modules and cables are not included.
f
g
Power supply modules (device back side)
Supply power to the device via the power supply modules
connectors. Please use the IEC power cable supplied (separately
available for WW devices).
Removing the power supply modules
To remove a power supply module from the device move the
release lever to the right and pull out the modules using the
handle.
4
Please observe the following when setting up the device
A The mains plug of the device must be freely accessible.
A For devices to be operated on the desktop, please attach the adhesive rubber
footpads.
A Do not rest any objects on top of the device and do not stack multiple devices.
A Keep the ventilation slots on the side of the device clear of obstruction.
A Mount the device into a 19” unit in a server cabinet using the provided screws and mounting rails.
d ETH 1 - ETH 8 - TP (one green and orange LED each)
Both LEDs off No networking device attached
Green, permanently Connection to network device operational,
no data trafc
Green, ickering Data transmission
Orange off 1000 Mbps
Orange, permanently 100 Mbps
a Power- / Status- / HDD LEDs
Power: off Device switched off
Power: green,
permanently
Device operational
Statrus: green,
permanently*
Device operational, resp. device paired /
claimed and LANCOM Management Cloud
(LMC) accessible
Status: green / red,
blinking
No password set. Without a password
the conguration data in the device is
unprotected.
Status: red, blinking Charge or time limit reached
Status: 1x green,
inverse blinking*
Connection to the LMC active, pairing OK,
device not claimed
Status: 2x green,
inverse blinking*
Pairing error, resp. LMC activation code
not available
Status: 3x green,
inverse blinking*
LMC not accessible, resp. communication
error
HDD: off no HDD read- / write access
HDD: green, ickering HDD read- / write access
b LCD display (rotating in two lines)
A Device name
A Firmware version
A Device temperature
A Date and time
A CPU load
A Memory usage
A Number of VPN tunnels)
A Data transfer in reception direction
A Data transfer in transmission direction
This product contains separate open-source software components which are subject to their own licenses, in particular
the General Public License (GPL). The license information for the device rmware (LCOS) is available on the device‘s
WEBcong interface under “Extras > License information“. If the respective license demands, the source les for the
corresponding software components will be made available on a download server upon request.
e ETH 9 - ETH 10 - SFP+ (one orange LED each)
Off No networking device attached
Orange, permanently Connection to network device operational,
no data transmission
Orange, ickering Data transmission
ISG-8000
ETH 9 ETH 10
a
b e
c
d
ISG-8000
ETH 9 ETH 10
a
c d e
ISG-8000
ETH 9 ETH 10
b
c Display buttons A - D
All buttons are fully congurable
F
F
G
G
Before initial startup, please make sure to take notice of the information regarding the intended use in the enclosed installation guide!
Operate the device only with a professionally installed power supply at a nearby power socket that is freely accessible at all times.
Detailed mounting instructions can be found under www.lancom-systems.com in the product area for this device under ‘downloads’.


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Lancom ISG-8000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Lancom ISG-8000 in the language / languages: English as an attachment in your email.

The manual is 0,52 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Lancom ISG-8000

Lancom ISG-8000 Installation Guide - English - 18 pages

Lancom ISG-8000 Installation Guide - German - 18 pages

Lancom ISG-8000 Quick start guide - German - 1 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info