Accessories2 Ethernet cables, 3 m (kiwi colored connectors); 1 serial conguration cable 1.5 m;
1 IEC power cord 230 V (not for WW devices); 1 grounding screw
MOUNTING AND CONNECTING THE DEVICE
*) The additional power LED statuses are displayed in 5-seconds
rotation if the device is congured to be managed by the LANCOM
Management Cloud.
LANCOM, LANCOM Systems and LCOS are registered trademarks. All other names or descriptions used may be trademarks or registered
trademarks of their owners. Subject to change without notice. No liability for technical errors and/or omissions. 111749/0718
LANCOM ISG-4000
Quick Reference Guide
Cloud-ready
a
USB interface
You can use the USB interface to connect a USB printer or a USB
storage device.
b
Serial conguration interface
Use the included serial conguration cable to connect the serial
interface (COM) to the serial interface of the device you want to
use for conguring / monitoring.
c
SFP / TP Ethernet interfaces (combo ports)
Insert suitable SFP modules into the SFP ports ETH 1 - ETH 4.
Choose cables compatible with the SFP modules and connect them
as described in the module’s documentation. SFP modules and
cables are not included.
d
If desired, alternatively connect the ETH 1 - ETH 4 TP Ethernet inter-
faces to your PC or a LAN switch using one of the enclosed cables
with the kiwi-colored connectors.
e
TP Ethernet interface
Use one of the enclosed cables with the kiwi-colored connectors to
connect the interface ETH 5 to your PC or a LAN switch.
f
SFP+ interfaces (10G)
Insert suitable SFP modules into the SFP ports ETH 6 - ETH 7.
Choose cables compatible with the SFP modules and connect
them as described in the module’s documentation.
SFP modules and cables are not included.
g
Reset button
Pressed up to 5 seconds: device restart
Pressed until rst ashing up of all LEDs:
conguration reset and device restart
h
Power connector and grounding point (device back side)
Supply power to the device via the power connector. Please
use the IEC power cable supplied (separately available for WW
devices).
Warning! High touch current.
Connect to earth before
connecting the power supply.AC Line: 100-240 V 50-60 Hz
i
ATTENTION: High touch current possible! Connect to earth
before connecting the power supply. For this purpose, remove
the existing blind screw and use the enclosed grounding screw
instead.
4
Please observe the following when setting up the device
AThe mains plug of the device must be freely accessible.
AFor devices to be operated on the desktop, please attach the adhesive rubber
footpads.
ADo not rest any objects on top of the device and do not stack multiple devices.
A Keep the ventilation slots on the side of the device clear of obstruction.
AMount the device into a 19” unit in a server cabinet using the provided screws and mounting brackets.
H
I
LANCOM ISG-4000
RESET
COMUSB
TEMP
POWER
ETH 5ETH 6 (10G)ETH 7 (10G)
ETH 3
ETH 4
ETH 1
ETH 2
a
bcd
e
cdg
dETH 1 - ETH 4 - TP (one green and orange LED each)
Both LEDs offNo networking device attached
Green, permanentlyConnection to network device operational,
no data trafc
Green, ickeringData transmission
Orange off1000 Mbps
Orange, permanently10 / 100 Mbps
bTEMP
Green, permanentlyCPU temperature OK
Red, blinkingHardware failure of the fan or CPU
temperature too high; additional acoustic
signal
eETH 1 - ETH 4 - SFP (one green and orange LED each)
Both LEDs offNo networking device attached
Green, permanentlyConnection to network device operational,
no data trafc
Green, ickeringData transmission
Orange off1000 Mbps
Orange, permanently10 / 100 Mbps
aPOWER
OffDevice switched off
Green, permanently*Device operational, resp. device paired /
claimed and LANCOM Management Cloud
(LMC) accessible
Green / red, blinkingNo password set. Without a password
the conguration data in the device is
unprotected.
Red, blinkingCharge or time limit reached
1x green inverse
blinking*
Connection to the LMC active, pairing OK,
device not claimed
2x green inverse
blinking*
Pairing error, resp. LMC activation code
not available
3x green inverse
blinking*
LMC not accessible, resp. communication
error
cLCD display (rotating in two lines)
ADevice name
AFirmware version
ADevice temperature
ADate and time
ACPU load
AMemory usage
ANumber of VPN tunnels)
AData transfer in reception direction
AData transfer in transmission direction
fETH 5
Both LEDs offNo networking device attached
Green, permanentlyConnection to network device operational,
no data trafc
Green, ickeringData transmission
Orange off1000 Mbps
Orange, permanently10 / 100 Mbps
This product contains separate open-source software components which are subject to their own licenses, in particular
the General Public License (GPL). The license information for the device rmware (LCOS) is available on the device‘s
WEBcong interface under “Extras > License information“. If the respective license demands, the source les for the
corresponding software components will be made available on a download server upon request.
f
LANCOM ISG-4000
RESET
COMUSB
TEMP
POWER
ETH 5ETH 6 (10G)ETH 7 (10G)
ETH 3
ETH 4
ETH 1
ETH 2
a
bc
edd
ef
g
gETH 6 - ETH 7 - SFP+ (one blue LED each)
OffNo networking device attached
Blue, permanentlyConnection to network device operational,
no data trafc
Blue, ickeringData transmission
Need help? Post your question in this forum.
Report abuse
Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.
Product:
Forumrules
To achieve meaningful questions, we apply the following rules:
First, read the manual;
Check if your question has been asked previously;
Try to ask your question as clearly as possible;
Did you already try to solve the problem? Please mention this;
Is your problem solved by a visitor then let him/her know in this forum;
To give a response to a question or answer, do not use this form but click on the button 'reply to this question';
Your question will be posted here and emailed to our subscribers. Therefore, avoid filling in personal details.
Register
Register getting emails for Lancom ISG-4000 at:
new questions and answers
new manuals
You will receive an email to register for one or both of the options.
Get your user manual by e-mail
Enter your email address to receive the manual of Lancom ISG-4000 in the language / languages: English as an attachment in your email.
The manual is 0,4 mb in size.
You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.
If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.
The email address you have provided is not correct.
Please check the email address and correct it.
Your question is posted on this page
Would you like to receive an email when new answers and questions are posted? Please enter your email address.