513873
13
Zoom out
Zoom in
Previous page
1/13
Next page
GWS 457.0 13
Technische Daten
Tabelle der zugelassenen Gasarten und Drücke
Belastungstabelle
Gesamt-Nennwärmebelastung = 6,0 kW
Anschlußwert des Gerätes = 437 g/h
Elektrische Anschlußwerte
Anschluß erfolgt über den Netzstecker an eine Steckdose.
Gesamtleistung < 20 W
Anschlußwerte 230 - 240 V, 50 Hz
Sicherungsstrom 16 A
Brennwerte nach EN 437
Der Betriebsbrennwert H
SB
ist am Aufstellort bei zuständigen Gasversorgungs-
unternehmen zu erfragen.
Der Gasdurchgang wird wie folgt berechnet:
Belastung kW x 1000
Gasdurchgang in l/min =
Betriebswert kWh/m
3
x 60
Land
(ISO-Länderkürzel)
Erdgas H, E
(G 20)
Erdgas LL
(G 25)
Erdgas L
(G 25)
Druckpaar
Erdgas E+
(G 20/25)
Druckpaar
(Butan/Propan)
(G 30/31)
Butan
(Butan/Propan)
(G 30)
Kategorie
mbar mbar mbar mbar mbar mbar mbar
Deutschland (DE) 20 20 50 II
2ELL3B/P
Dänemark (DK)
Finnland (FI)
Schweden (SE)
20 28-30 II
2H3B/P
Niederlande (NL) 25 28-30 II
2L3B/P
Frankreich (FR) 20/25 28-30/37 II
2E+3+
Ver. Königreich (GB)
Spanien (ES)
Italien (IT)
Portugal (PT)
Irland (IE)
Griechenland (GR)
20 28-30/37 II
2H3+
Österreich (AT) 20 50 II
2H3B/P
Luxemburg (LU)
Belgien (BE)
20 28-30/37 I
2E
, I
3+
Brenner Erdgas
20 mbar
25 mbar
Butan/Propan
Belastung
kW
Belastung
kW
Gasdurchgang
g/h
Außenbrenner groß 5,6 5,6 408
klein 1,2 1,2 88
Innenbrenner groß 0,4 0,4 29
klein < 0,18 < 0,18 < 14
Gasart Brennwert H
s
15 °C
MJ/m
3
kWh/m
3
MJ/kg kWh/kg
Erdgas H (G 20) 37,78 10,5
Erdgas L (G 25) 32,49 9,03
Butan (G 30) 49,47 13,75
Propan (G 31) 50,37 14,00
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kuppersbusch GWS 457.0 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kuppersbusch GWS 457.0 in the language / languages: German, Dutch as an attachment in your email.

The manual is 0,41 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kuppersbusch GWS 457.0

Kuppersbusch GWS 457.0 User Manual - Dutch - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info