686414
14
Zoom out
Zoom in
Previous page
1/30
Next page
FastMig X 350MV
12
EN
Language
Select your menu language
Select Feeder (WF#)
Select another parallel wire feeder as a setup target
MMA/CC/CV Mode
Activate MMA welding, or use CC or CV mode for ArcFeed or MasterTig LT
250
4. Adjustment knob
Turn the knob to change the value of the selected parameter. In MMA/CV/CC mode when
panel is in default initial view (channel information), knob can be used to adjust current
(MMA and CC) or voltage (CV).
5. Menu browsing buttons
Use up and down arrows to move the selection up and down in the menu structure. In
MMA/CV/CC mode when panel is in default initial view (channel information), Up/Down
buttons can be used to adjust Arcforce (MMA) and Dynamics (CV/CC).
6. Menu shortcut buttons
• F1 (CHANNEL INFO) displays the basic data recorded to the displayed channel. Pressing
F1 multiple times gives more information of the selected memory channel. Keeping F1
pressed while turning the machine ON restores the menu language to English.
• F2 (USER) Browses and selects users: 1…10, Administrator. When MMA/CC/CV is
selected, only Administrator is allowed.
• F3 (WF#) Selects another wire feeder as a setup target. Panel allows selecting only those
WF numbers that are found connected on the system. When MMA/CC/CV is selected, the
display shows text ”MMA/CC/CV Mode”.
NOTE! FastMig X 350MV allows up to 3 wire feeders to be connected to one power source. Only
one wire feeder can be active at a time and must be selected before it will operate.
7. LCD menu display
8. Soft key buttons for menu selection
Use these buttons to select menu items. Their functions depend on selected menu items.
The function is shown on the display.
4.2 Using the menus
4.2.1 Selecting the interface language
The default menu language is English. If you want to select another menu language, do the
following:
1. Connect the mains power and switch on the power source at the main switch.
• If this is the initial system activation (if SYSTEM OFF text is in the display), you may
need to press and hold the POWER ON button in the to left corner of the X 37 control
panel. Hold the button down for 5 seconds.
2. Press the MENU button to display the main menu, which includes 7 menu items.
• You can move around in the menu list by pressing the up and down arrow buttons.
• As you browse the menu item list, the currently selected item is shown at the bottom
of the display, marked as 1/7, 2/7, 3/7 etc.
• The selected menu item is marked with a black arrow-shaped cursor.
3. Browse to the menu item LANGUAGE (5/7) and press the SELECT soft key button.
4. Browse to your language and press the SELECT/SAVE soft key button. Your language choice is
now conrmed and will remain selected unless you change it later.
4.2.2 About memory channels
You can have several setups of welding parameter values for use in various welding
applications. These setups (or welding jobs) are stored as memory channels in X 37 control
panel.
Up to 10 user proles can be dened in one FastMig X 350MV unit, and each of them are
assigned up to 10 memory channels. So, you have maximum of 100 memory channels to
store your frequently used welding jobs. In addition to them, there are 10 memory channels
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kemppi FastMig X 350MV at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kemppi FastMig X 350MV in the language / languages: English as an attachment in your email.

The manual is 1,44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info