For use without the weight. The prefilter is functional with or without the weight (we rec-
ommend using with the weight). To use without the weight, remove the strainer barb from
the input hose. Re-assemble without the weight.
4. Storage: Your Katadyn water system comes with a carry bag for storage. To prevent the
possibility of cross contamination, remove the output hose and EasyFill Bottle Adaptor and
store separately in a re-sealable bag inside the carry bag.
LONG-TERM STORAGE (AFTER YOUR TRIP IS OVER)
Disinfect your microfilter before storage to prevent microbiological growth within the pump.
1. Fill a liter container with tap water and add 2 tablets of Micropur Forte DCCNa or
Micropur MP1. (Do not use Micropur Classic.)
2. Place prefilter into solution.
3. Pump entire amount of solution through unit (into sink or container).
4. Remove prefilter from the solution and continue pumping another 5 to 10 strokes to remove
remaining water from the pump body and hoses.
5. Remove cartridge and allow to dry.
6. Wrap hoses around body and store in carry bag.
Note: When removing unit from long-term storage, flush the system with one liter of water to
remove any stale tasting water.
CARTRIDGE CAPACITY
Cartridge capacity depends on water quality. The Katadyn Hiker Pro was tested at 750 liters
(without filter protector) and found effective for removal of bacteria (Klebsiella terrigena) and pro-
tozoan cysts (Giardia and Cryptosporidium). For maximum performance, cartridge should be
replaced after 750 liters or when the unit becomes hard to pump.
CARTRIDGE INSTALLATION
Replacement cartridges are available from the dealer where you purchased your Hiker Pro.
1. Remove output hose from cartridge output barb. Grasp the top of the Hiker Pro cartridge
and turn counter clockwise. If cartridge removal is not possible by hand, the handle shaft
will function as a cartridge removal tool:
Remove the handle collar and handle. Locate one of the deep grooves on either side of the
handle shaft. Lay the handle across the filter top and insert two of the “fins” on top of the
filter into one of the groves of the handle shaft. Hold the handle shaft in place firmly with
the palm of your hand. Using the handle shaft for leverage, apply even pressure and grad-
ually turn the cartridge counter clockwise. Use caution so that handle shaft does not slip and
cause damage. Discard used cartridge in trash receptacle.
2. Rinse inside of housing by swishing with clear water (non-filtered water is ok). Discard water.
Wipe inside of housing and housing threads with soft cloth to remove sediment.
3. Remove new cartridge from packaging.
4. Insert new cartridge into housing and tighten clockwise. Note - Apply silicone lubricant to
cartridge o-ring before re-assembly to ease cartridge removal in the future.
5. Re-attach output hose to cartridge output barb. (Figure 1-1)
6. Flush cartridge by pumping and discarding the first liter.
EN 
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Katadyn Hiker Pro Water Microfilter at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Katadyn Hiker Pro Water Microfilter in the language / languages: English as an attachment in your email.

The manual is 1,16 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Katadyn Hiker Pro Water Microfilter

Katadyn Hiker Pro Water Microfilter User Manual - German - 8 pages

Katadyn Hiker Pro Water Microfilter User Manual - Dutch - 8 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info