522398
4
Zoom out
Zoom in
Previous page
1/8
Next page
NORMAL OPERATION
1. Place input hose in untreated water source. Adjust the float to keep prefilter off the bottom
and away from sediment.
2. Insert the EasyFill Bottle Adaptor into a clean water container or connect hydration conec-
tor to bladder*. (Figure 2-1, 2-2)
3. Make sure the hoses are not kinked. Begin pumping the handle in a slow, steady manner.
Approximately 48 strokes per minute equals 1 liter of water.
4. After filling water container with filtered water, remove bottle adaptor/hydration connector
from container/bladder and prefilter from water source. Continue pumping to remove
remaining water from pump body.
5. Store unit in the carry bag. To prevent the possibility of cross contamination, remove the out-
put hose and EasyFill Bottle Adaptor and store separately in the re-sealable bag inside the
carry bag.
*Note: Before each use, flush and discard a small amount (5 10 strokes) of water to remove
stale taste.
FIELD PERFORMANCE TIPS
The Katadyn Hiker Pro is designed to remove bacteria and protozoan cysts such as Giardia and
Cryptosporidium. To extend cartridge life, always use the best water source available. Keep the
intake prefilter clean and off the bottom. In heavy sediment conditions, wrap a coffee filter or ban-
danna around the intake prefilter. Where possible, place untreated water in container and wait
for sediment to settle out until water appears clear - then filter from water above the sediment.
Maintain your Katadyn water system to keep it operating smoothly.
1. If handle is hard to push: 
Lubricate pump handle o-ring. Silicone lubricant is provided with your new unit. Remove
handle collar and handle. (Figure 1-1) Clean excess build-up from black rubber
o-ring on bottom of handle. Place a small amount of silicone lubricant all the way around
the o-ring. Re-assemble.
Clogged cartridge. A clogged cartridge requires replacement. As a temporary solution in
the field, remove the cartridge and swish it around in water. See also Hiker Pro removable
Filter Protector. Take care that untreated water does not contact the cartridge output barb. If
flow is not restored, replace cartridge. See Cartridge Installation for cartridge removal.
2. If unit pumps easily, but no water flow:
Make sure prefilter is submerged.
Make sure that hoses are not blocked or pinched.
Clean check valve. Occasionally, sediment may enter pump body and prevent check valve
from operating properly. This may cause lack of water draw. The check valve can
easily be cleaned to restore maximum water output. Remove the cartridge. Fill the pump
housing half way with water, swirl around and discard water. Fill the housing half way with
water again and reinstall cartridge. Pump slowly to get water started and resume normal
pump rate when flow has begun.
3. Prefilter: Rinse the prefilter in water to remove any particles that may be caught in the
strainer. For a more thorough cleaning, remove the prefilter from the input hose and clean
with water and a soft brush. Reassemble. Apply a small amount of silicone lubricant to the
strainer barb to ease assembly. (Figure 1-2)
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Katadyn Hiker Pro Water Microfilter at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Katadyn Hiker Pro Water Microfilter in the language / languages: English as an attachment in your email.

The manual is 1,16 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Katadyn Hiker Pro Water Microfilter

Katadyn Hiker Pro Water Microfilter User Manual - German - 8 pages

Katadyn Hiker Pro Water Microfilter User Manual - Dutch - 8 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info