554865
1
Zoom out
Zoom in
Previous page
1/2
Next page
The UC-82 wireless relay output module MHT51100
1
The UC-82 wireless relay output module
The UC-82 is a component of Jablotron’s JA-80 Oasis system. It is
powered by an external 12V DC power supply and it provides 2 relays
which can be controlled by radio signals and offers the following:
Remotely controllable relay outputs which follow JA-80 control
panel programmable PG outputs
Remote control of appliances using RC-8x controllers
Relay output of JA-8x wireless detectors
buttons
PCB tab
Y
Y
X
X
tamper
switch
ext.antenna connector
RADIO
1
2
3
4
LEDs
Installation
Installation of this module shall only be undertaken by technicians holding a
certificate issued by an authorized distributor.
Open the module’s cover (1 screw) and take out the circuit board (2
tabs). Install the back part of the housing to the desired place, re-install
the circuit board, connect the wires and enroll the desired wireless
devices. Connect an optional external antenna (AN-80 or AN-81) to the
relevant connector, if used (see the above diagram).
Terminals
+U, GND Power, 10 to 14V DC, stand-by consumption about 20mA
Low bat Low detector-battery indication, switches to GND (max.
100mA/24VDC)
TAMPER Normally-closed tamper contact
(max. 100mA/24VDC)
NC, C, NO Switchover relay (X and Y) contacts, (each max. 2A/24V DC
or 2A/120V AC)
The enrollment of transmitters
The X and Y relays are totally independent. Jablotron Oasis devices with
transmitters can be enrolled to them individually using the X and Y enrollment
buttons. Each relay offers 4 different enrollment modes (1 to 4, see the following
table). The reaction of a relay to a transmitter signal depends on which
enrollment mode the transmitting device has been enrolled to.
Enrollment procedure
Use X or Y button depending on which relay you want to enroll a device to.
Repeatedly press the relevant X or Y button to select the desired
enrollment mode 1 to 4 as indicated by the flashing of corresponding LEDs 1
to 4 (see the table for guidance on choosing the right enrollment mode).
Activate the transmitting device while the LED is flashing as follows:
o key fob –press a button
o detector –connect its battery up (if it has already been connected, first
disconnect it, then press and release the detector’s tamper switch)
o Control panel PG output –key in 299 in service mode
Enrollment is confirmed by a short flash from all the UC-82 indicators.
If no enrollment signal has been received within 10 sec., enrollment mode
automatically ends.
If you wish to enroll another device, repeat the above enrollment procedure
Notes:
If a device does not enroll, either it is too far from the receiver, or there is
another device already enrolled which cannot be combined with the new
one, or the maximum number of devices has been exceeded.
Each device can have its own individual reaction (it is possible to combine
different reactions for a single relay = enrolling different devices in different
enrollment modes to the same relay)
The relay always performs the last received instruction (e.g. if the relay is
already on and a signal for a 2 minute pulse is received, the relay will stay
on for another 2 minutes and then it will turn off).
Each transmitting device (keyfob, detector, control panel, etc.) can be
enrolled to an unlimited number of different receivers.
Devices are enrolled to a non-volatile memory, so the UC-82 will not forget
them if its power is disconnected.
Use with RC-8x remote controllers
Up to 60 remote controllers can be enrolled to each relay.
To operate garage door or parking gate actuators, use the 1 sec. pulse
mode and connect the NC relay contact to the push button input of the
actuator unit.
Use with JA-8x wireless detectors
Detectors can be enrolled to pulse modes (up to 60 detectors to each relay).
The 2 minute mode is suitable for automatically switching on lights,
ventilators etc.
If a detector(s) is enrolled in mode 3, then the relay will be switched if the
detector’s tamper sensor is triggered. In this mode up to 8 detectors can be
enrolled to a single relay (it will be switched if any of the detectors is tampered
with), but no other kind of device can be enrolled, only detectors.
If a detector(s) is enrolled in mode 4, then the relay triggers if the detector’s
sensor is triggered. In this mode up to 8 detectors can be enrolled to a single
relay (which triggers if any of the detectors is triggered), but no other kind of
device can be enrolled, only detectors.
The Low bat output switches to GND if any of the enrolled detectors signals
a low battery.
Mode. Reaction Device Enrollment method
Max.
number
Notes
key fob button pressing
1 1 sec. pulse
detector connecting battery up
60
key fobs and detectors can be combined
the relay stays on 1sec, turns off and is then ready to be activated again (the pulse is not
extended if another 1 sec. pulse activation signal is received while the relay is still on)
key fob button pressing
2 2 min. pulse
detector connecting battery up
60
key fobs and detectors can be combined
if another 2min. activation signal is received while the relay is on for 2 min., then the relay
stays on 2 min. more (the 2 minute pulse is extended if re-activated during the pulse)
Latch * key fob button pressing 60
3
Tamper= on detector connecting battery up 8
impossible to combine keyfobs with detectors
* latch = on – off – on – off….
Tamper = on = relay turns on when a detector’s tamper sensor is triggered.
key fob button pressing 60
impossible to combine keyfobs with detectors or a control panel PG output
on / off
PG output of
control panel
entry of 299 in Service
mode
1
impossible to combine PG output with detectors or keyfobs
4
Triggering =on detector connecting battery up 8
impossible to combine detectors with keyfobs or with a control panel PG output
1


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Jablotron UC-82 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Jablotron UC-82 in the language / languages: English as an attachment in your email.

The manual is 0,07 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info