554914
2
Zoom out
Zoom in
Previous page
1/2
Next page
UC-280 wireless interface 2 / 2 MFT51208
Connectors:
OUT data connector for UC-282 expander module
ANT AN-01A external antenna connector (when AN-01A is used,
the rod antenna must be disconnected)
Setting buttons:
LEARN if this button is briefly pressed, you can scroll through the
learning modes of Z1-Z8 zones and a wireless siren SIR (a
selected channel is indicated by a red flashing LED). When
this button is pressed for more than 3 sec., the enrolling
signal for a UC-216 / UC-222 receiver will be transmitted
(learning mode of Z1-Z8 and SIR must be closed first)
RESET if this button is briefly pressed, the learning mode of a
selected zone will be closed. When this button is pressed for
more than 3 sec., a selected zone will be deleted (confirmed
by flashing of the TMP, BAT and TRB indicators). When this
button is pressed for more than 6 sec., all zones will be
deleted (confirmed by flashing of all indicators). Note, in
order to delete all zones, a learning mode of any zone must
be selected first.
Jumpers:
1s / 3s pulse length of 1 sec. or 3 sec. of Z1-Z8 output relays
NO / NC normally closed or normally opened mode of Z1-Z8 output
relays (TMP, BAT and TRB are normally closed)
Supervision - Regular checking of wireless detectors’ communication
can be disabled (NO SUPERVISION position). This setting
is recommended in places with radio interferences. When
the supervision is enabled, lost communication will trigger
the TRB output relay.
Indicators:
POWER The green LED indicates the presence of the power supply
Z1 - Z8, LED lights green when zone is occupied;
LED lights red when zone detector is triggered;
LED flashes red, when zone is in a learning mode;
LED flashes red together with the TMP, BAT or TRB LED =
tamper, low battery or trouble signal in zone
TMP tamper alarm – flashes together with a corresponding zone
indicator every 3 sec.
BAT low battery - flashes together with a corresponding zone
indicator every 3 sec.
TRB trouble or lost communication - flashes together with a
corresponding zone or SIR indicator every 3 sec.
Enrolling of wireless components
Enrolling of detectors
Scroll to a desired zone Z1-Z8 using the LEARN button
JA-60 detectors will be enrolled by inserting their batteries or
switching on a power supply
Successful learning is indicated by the red LED
If you enroll a component to a new zone, it will move from its
previous position
Only one detector can be enrolled to each zone
Enrolling of remote controls
Scroll to a desired zone Z1-Z8 using the LEARN button
RC-xx remote controls will be enrolled by pressing a button (while in
pulse mode). Button A, B or double press can be enrolled.
RC-11 or RC-22 Remote controls can be enrolled to any zone in an
ON/OFF mode by pressing both buttons and keeping them pressed
for more then 5 sec. After this the corresponding relay will switch on
when the A button is pressed, and off, when the B button is pressed.
If a combination of double press and ON/OFF mode is required, the
ON/OFF mode must be enrolled first.
Successful learning is indicated by the red LED
If you enroll a remote control to a new zone, it will move from its
previous position
Only one remote control can be enrolled to each zone
Enrolling of a wireless siren
Connect a battery in a JA-60A siren and power its adapter
Select the SIR position with the LEARN button
When the SIR position is selected, the UC-280 will send a learning
signal to the JA-60A and vice versa. Triggering the SIR input will
then activate a JA-60A, tamper alarm or power supply failure of the
JA-60A will be transmitted to a UC-280
Only one JA-60A siren can be used with a UC-280
Enrolling of UC-216 or UC-222 modules
SIR
Select the learning mode in a receiver (mode X1 for UC-216 or
mode 4 for UC-222)
Learning mode of UC-280 must be closed
Press and hold the LEARN button in UC-280 for 3 seconds
The UC-280 will now be enrolled to the UC-216 or UC-222 receivers
and triggering of X and Y inputs will trigger the UC-216 / UC-222
output relays.
Unlimited number of UC-216 / UC-222 can be used with a UC-280
Erasing components
If you want to delete any item from a UC-280, use the RESET button
(the procedure is described in “Setting buttons” paragraph).
Extension for more zones
When 8 zones are not enough, you can use UC-282 expander
modules. Each UC-282 module provides additional 8 zones. A
maximum of 4 expanders can be used with UC-280. Modules are
interconnected using the IN and OUT connectors, wiring should not
exceed 1 meter. Each UC-282 must be powered by 12 V DC
separately.
Internet: www.jablotron.cz
Tel.: +420 483 559 999
fax: +420 483 559 993
Pod Skalkou 33
466 01 Jablonec nad Nisou
Czech Republic
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Jablotron UC-280 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Jablotron UC-280 in the language / languages: English as an attachment in your email.

The manual is 0,1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email