554896
11
Zoom out
Zoom in
Previous page
1/12
Next page
Telephone dialer TD-101 / TD-101W - 14 - MDJ512 10 Telephone dialer TD-101 / TD-101W - 11 - MDJ512 10
8.7. Number of attempts to call monitoring station
Number of attempts to call MS can be programmed in the installer mode (the yellow LED is ON - see
8.1.), entering:
F
D
D
is a number of attempts to call monitoring station, can be from 1 to 8. A successful
communication handshake cancels all following attempts.
(factory default setting are 3 attempts)
Example: Five cycles will be selected :
F

8.8. Telephone line signals detection
Detection of signals can be enabled or disabled in the installer mode (the yellow LED is ON - see
8.1.), entering:
F
D
where:
D
=0 detection disabled
D
=1 detection enabled (factory default setting)
If the telephone line signals detection is enabled, the dialer will check for the dial tone at first. If a
dial tone is not present, it will try to release the line again. Then it will dial the first stored number and if
it gets a ringing tone, it will send the message once and it will not call this number again.
If the number is busy, it will dial the next number and the dialing will be repeated after that.
If the signals detection is disabled, the dialer will make as many cycles as programmed in
F
, no
matter what the signals on the line are.
Example: Detection will be disabled :
F

8.9. Audible function monitor (built in speaker)
The built in speaker can be enabled or disabled to listen the dialing and calling. It can be selected in
the installer mode (the yellow LED is ON - see 8.1.), entering:
F
D
where:
D
=0, disabled
D
=1, enabled (factory default setting)
The audible line monitoring with built in speaker is always enabled when you test the TD-101.
Example: The audible dialing monitor will be enabled :
F

8.10. Stop function with Ekey
Stop function is selectable in the installer mode (the yellow LED is ON - see 8.1.), entering:
F
D
where:
D
=0 stop is disabled
D
=1 stop is enabled (factory default setting)
7.4. Monitoring station Communication Protocol & Format setting
Protocol and format can be selected in the Installer mode (the yellow LED is ON - see 7.1.), entering:
M
DE
where:
D
means protocol and
E
means format, see the following table:
D
protocol
E
format
0 ADEMCO / SILENT KNIGHT SLOW 10 BPS 0 3/1 not extended
1 SESCOA, FRANKLIN, DCI, VERTEX 20 BPS 1 3/2
2 SILENT KNIGHT FAST 20 BPS 2 4/1
3 RADIONICS (2300) 3 4/2
4 RADIONICS (1400) 4 3/1 extended
8 DTMF 1400
9 DTMF 2300
Example: SILENT KNIGHT FAST 20 BPS protocol and 4/1 format will be selected
M

7.5. Account number programming
Account number code can be entered in Installer mode (the yellow LED is ON - see 7.1.), entering:
M
EEEE
where :
EEEE
is the account number. If format 3/1 or 3/2 is selected (see 7.4. above) the first digit will not
be sent.
Transmitted codes are usually „HEX“ data, i.e. each digit can be 0 to 15 (F). To enter HEX data,
use
key. Enter number 10(A) as

, 11(B)=

, 12(C)=

, 13(D)=

, 14(E)=

, 15(F)=

.
Number 0 in account number must be entered as

.
Example: Account number 12A5 will be stored :
M

7.6. Reporting codes programming
Reporting codes for activation and deactivation of the dialer inputs can be programmed in the
installer mode (the yellow LED is ON - see 7.1.), entering:
M
D
EE
where:
D
means event on the inputs, see following table:
input activation deactivation
IN1 3 4
IN2 5 6
%E
is the report code for MS, (if
%E
= 00 is selected, this event will not be reported)
Transmitted codes are usually „HEX“ data, i.e. each digit can be 0 to 15 (F). To enter HEX data, use
key.
Enter number 10(A) as

, 11(B)=

, 12(C)=

, 13(D)=

, 14(E)=

, 15(F)=

.
Example: Code 3D will be reported if IN2 input is triggered :
M

11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Jablotron TD-101 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Jablotron TD-101 in the language / languages: English as an attachment in your email.

The manual is 1,41 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info